User manual RANE ECM 64

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual RANE ECM 64. We hope that this RANE ECM 64 user guide will be useful to you.


RANE ECM 64 : Download the complete user guide (561 Ko)

You may also download the following manuals related to this product:

   RANE ECM 64 SCHEMA (312 ko)
   RANE ECM 64 DATASHEET (229 ko)

Manual abstract: user guide RANE ECM 64

Detailed instructions for use are in the User's Guide.

[. . . ] OPERATORS MANUAL ECM 64 CONFERENCE SYSTEM Quick Start The ECM 64 is a very versatile product with many applications. This section will help you with basic setup, then use the Contents below to find the detail you need for your specific application. Although the ECM 64 or ECM 64AD are configured to operate `out of the box', to get the best performance please review this manual for proper configuration and alignment (see page Manual-12). The ECM 64AD includes both the DH 1 Digital Hybrid and the ECA 1 Echo Canceller. [. . . ] Right-click on the title bar to Select Device Edit (password required), or Exit the program. If more than 16 Memories are needed, they can be saved to disk and recalled later. Memory Selection Toolbar All of Rane's RW 232 products have 16 programmable Memories with one working Memory called Memory 0. Recalling a Memory replaces the working Memory with the selected Memory. All control changes are made to working Memory, not to the selected Memory. The selected Memory flashes whenever working Memory does not match it. To save these settings in one of the 16 Memories, simply click Store, and the Memory number key. The 16 Memories are stored within the units non-volatile Memory, and recalled by: Selecting a Memory using RaneWare, or from a control system by a. Sending a Program all channels from memory on all devices command Recalling settings allows the room controller to make routing changes without affecting the input and output levels. There are three separate Memory recall options that are available to a room controller: a. Recall Output settings only See Program channel from memory on page Manual-17 in the Device Control Language. Saving & Printing From the Device menu, both memories and names can be saved and retrieved to and from a file. To save both memories and names, select Device > Backup Memories to File. This allows you to create systems that operate the same but have separate Names. To retrieve Memories from a file select Device > Restore Memories from File. To retrieve Names from a file select Device > Restore names from File. A printout report of Mic Mix, Out 1 through Out 3, Hybrid, AEC and stored phone numbers per memory is available under Device > Print Device Report. Device, Input and Output Names Dialog ECM 64 can operate all the time through a computer if a system controller is not installed. To preserve Memory security with a computer operator, the software can be locked (under Device), and a system password can be assigned (under System > Change Password). Memories can be customized with names, through System > Site Control Panel Setup. If only a few presets are required, blanking an entry in the Site Control Panel Setup removes the screen button. Memory names are stored in the computer, not in the ECM Manual-9 ECM 64 Input and Output Controls Inputs Each Input has programmable Trim and Mute controls. The Input is calibrated so if it is set to 0 dB, a 0 dBu input gives a 0 dB Meter level. Outputs Each Output has a programmable six-channel matrix mixer, a programmable Output Trim, a Mute button and a Limiter checkbox. [. . . ] An excessive number of RENs connected to a telephone line may result in devices not ringing to an incoming call. Consult with you telephone company to obtain the maximum RENs for your area. Should this equipment cause harm the telephone network, the telephone company will notify you in advanced that temporary disconnect of service might be required. If it is not practical for the Telephone Company to give an advanced notice, they will notify the customer as soon as possible. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE RANE ECM 64




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual RANE ECM 64 will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.