User manual RANE CP 64S

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual RANE CP 64S. We hope that this RANE CP 64S user guide will be useful to you.


RANE CP 64S : Download the complete user guide (568 Ko)

You may also download the following manuals related to this product:

   RANE CP 64S SCHEMA (499 ko)
   RANE CP 64S DATASHEET (679 ko)

Manual abstract: user guide RANE CP 64S

Detailed instructions for use are in the User's Guide.

[. . . ] OPERATORS MANUAL CP 64S COMMERCIAL PROCESSOR PAGING ZONE ASSIGN PAGE 1 PAGE 2 12 12 RMT 1&2 RMT 1&2 2 0 4 LEVEL ZONE 2 4 8 10 2 0 10 6 8 2 0 PROGRAM INPUT LEVELS LINE 1 4 6 8 10 2 0 10 ZONE 1 DUCKER DEPTH PROGRAM SELECT L2 L3 L1 P 2 ZONE 2 LEVEL 4 6 8 0 10 ZONE 1 LEVEL 4 2 6 8 0 10 12 6 0 6 12 · · · · ZONE 2 + ZONE 1 6 LINE 2 4 6 8 2 LINE 3 4 6 8 0 10 2 PRIORITY 4 6 8 0 10 DUCKER DEPTH PROGRAM SELECT L2 L3 L1 P CP 64S COMMERCIAL PROCESSOR OFF ON RMT SIG OL OFF ON RMT SIG OL ACTIVE ACTIVE 40 100 250 630 1. 6k 4k 10k 40 100 250 630 1. 6k 4k 10k POWER QUICK START If you were the type that cheated on school book reports by just skimming through the reading assignments, then this section is for you!It gives you not quite enough information to really know what you're doing. But, if you follow the recommended set up procedure, you should get at least a "B. " Keep the amplifiers and the CP 64S turned off until all connections are made. INTERNAL SETTINGS Access to the following internal controls requires removal of the top cover. [. . . ] The dot on the circuit board shows the factory default: 1 Page 1 Phantom Power 15VDC Default: OFF 2 Page 2 Phantom Power 15VDC Default: OFF 3 Page Priority P1, NO, P2 Default: P1 4 Zone 1 Page Sum Pre- or Post-VCA Default: Pre-VCA 5 Zone 2 Page Sum Pre- or Post-VCA Default: Pre-VCA 1 2 Phantom Power is available for both Page Inputs. If phantom power is required for the intended microphone, then set the appropriate switch to ON. If a Paging Input Mic / Line pad switch is set to LINE, Phantom Power is automatically defeated. 3 Page Priority Assign allows you to select one of the Page Inputs as a Priority Page Input. The Priority Pager overrides the non-priority Pager in the Zone(s) it is assigned. Note that the non-priority Pager may still broadcast in any Zone that the Priority Pager is not assigned to or not currently broadcasting in. If you wish Page 2 to have priority over Page 1, set the switch to P2. If NO is selected, neither Paging Input has priority and both Pagers may be active at the same time. This allows the Paging Inputs to mix for applications like karaoke or PA. If a Page Input is used for emergency paging, set it as the Priority Pager. 6 1 3 2 7 8 45 Manual- 4 5 The Zone 1 Page and Zone 2 Page switches allow you to sum Page signals with Program signals "Pre" (before) or "Post" (after) the VCA. Therefore, if you require the Page Level to be controlled independent of the Program Level, set the switch for that Zone to "Post. " This is the desired setting for emergency paging. If a unit is located far from the CP 64S or is of a type that might create grounding problems, isolation transformers should be used. When operating cross-coupled line drivers unbalanced (i. e. , any CP 64S Output), it is essential to ground the (­) pin. The same guidelines given above for unbalanced operation apply to these Inputs. See the RaneNote Sound System Interconnection (included in this booklet) to answer any uncertainties, especially when using unbalanced sources. REMOTE INSTALLATION The CP 64S supports wired remotes for Page Assign, Zone Level and Zone Source selection. A brief list of suitable wire types is provided in the WIRE TYPES section on the next page. The PR 2 remote provides Page Zone Assign for Page 1 and Page 2 inputs and is usually located at the Page source. If your application requires one of the two PAGE ASSIGN switches to control both Page 1 and Page 2 Assign, simply wire all Page 1 and Page 2 ports in parallel. You may leave the knob off the unused control and cover it with one of the hole plugs provided in the kit. If your installation requires Page 1 and Page 2 remote control at two different locations, only three wires are required for each PR 2 remote (Z1, Z2 & GND). As above, you may leave the knob off the unused control and cover it with a hole plug. The ZR 1 remote provides Zone Level and Source Selection, allowing local control from inside the Zone. [. . . ] at factory (internal adjust 2 to 20 sec. ) As required (Zone/Program/Page) CW, +20 dBu Max L1 (if your input is on L1). OFF Center (about 15 dB) Out Flat (center detent position) As required (Zone 1 only, default:stereo) Zone Settings (repeat for second zone): · Expand Out rear panel · Limiter Threshold rear panel · Zone Level front panel · Program Select front panel · Ducker front panel · Ducker Depth front panel · RMT (Remote) front panel · EQ front panel · Stereo / Mono switch internal System Connections: · Connect page mics or line-level paging source · Connect Program sources · Connect Outputs to amplifiers · Connect Remotes You are now ready to calibrate the CP 64S. . . Verify Zone Level controls are set to Maximum and that you have an active source for each of the Program Inputs you intend to use. Select each Program Input and adjust its Input Level control to be the very loudest you would ever desire. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE RANE CP 64S




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual RANE CP 64S will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.