User manual QUANTUM SCALAR AIT 440

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual QUANTUM SCALAR AIT 440. We hope that this QUANTUM SCALAR AIT 440 user guide will be useful to you.


QUANTUM SCALAR AIT 440 : Download the complete user guide (9455 Ko)

Manual abstract: user guide QUANTUM SCALAR AIT 440

Detailed instructions for use are in the User's Guide.

[. . . ] SCALAR AIT 440/480 INSTALLATION AND OPERATING GUIDE Scalar AIT 440/480 Libraries Installation and Operation Copyright Copyright 1998 by Advanced Digital Information Corporation (ADIC). This item and the information contained herein are the property of ADIC. No part of this document may be reproduced, transmitted, transcribed, stored in a retrieval system, or translated into any language or computer language in any form or by any means, electronic, mechanical, magnetic, optical, chemical, manual, or otherwise, without the express written permission of ADIC, 11431 Willows Road N. E. , Redmond, Washington 98052. Disclaimer ADIC makes no representation or warranties with respect to the contents of this document and specifically disclaims any implied warranties of merchantability or fitness for any particular purpose. Further, ADIC reserves the right to revise this publication without obligation of ADIC to notify any person or organization of such revision or changes. Trademark Notices ADICTM, ADIC EuropeTM and ScalarTM are trademarks of Advanced Digital Information Corporation. [. . . ] When the drive is almost completely inside the slot, you will feel some resistance. This is caused by the connection between the library's controller card and the tape drive. To seat the connection, push firmly against the drive until you can push no further. Using a flat-blade screwdriver, tighten the captive screw on each end of the drive carrier faceplate (two screws). Step 4 ­ Resume library operations 1. Note: When you replace a tape drive, the new tape drive automatically assumes the SCSI ID of the old tape drive. See page 34 if you want to change the ID. 84 Scalar AIT 440/480 Maintaining the Library Replacing the fuse The library uses a 4. 0-amp, 250-volt fuse, which is located in the fuse drawer at the back of the library next to the power cord connector. Replacement fuses are available from ADIC. CAUTION When replacing the fuse, use only the same type and rating of fuse. To replace the fuse: 1. Turn off the library and remove the power cord. WARNING! Before performing any installation or maintenance procedures, be sure that the library power switch is in the off position and that the power cord is disconnected from the library and the outlet. 2. Lift out the fuse drawer. Installation and Operation 85 Chapter 6 Figure 6-2 Replacing the fuse 3. Use the screwdriver to push the spare fuse box out of the fuse drawer. Place another spare fuse in the spare fuse box and replace the spare fuse box in the fuse drawer. Push it in as far as you can. 86 Scalar AIT 440/480 Maintaining the Library Replacing the air filter The library has two air filters, one on each side of the front panel (see Figure 6-3). You should replace the air filters once a year (or more frequently if the library is operating in a dirty environment). Replacement filters are available from ADIC. ³ Important Air filters protect the library from large contaminants, but are not intended to keep the tape drives clean. To help maintain data integrity and reliability, you should clean the tape drives on a regular basis. See page 69 for more information. Installation and Operation 87 Chapter 6 To replace the air filters: 1. As shown in Figure 6-3, push against the outer edge of each air filter grille and pull the grille off the front panel. Figure 6-3 Replacing the air filters 88 Scalar AIT 440/480 Maintaining the Library 2. Remove the air filter from inside of the air filter grille (see Figure 6-4). Place a new filter inside each grille, tucking the mesh over the mounting pins inside the grille. Figure 6-4 Replacing the air filter inside the air filter grill 4. Replace each grille by inserting the tabs into the holes and pushing against the grille until it is seated. Installation and Operation 89 Chapter 6 Cleaning the front window Aside from the tape drives, the only library component that you should clean is the window in the front door. Two cleaning packets are provided with your library for cleaning the front window. To order additional cleaning packets, contact ADIC Sales. CAUTION To avoid scratching the window, do not use abrasive cleaners, abrasive cleaning implements, harsh chemicals, or solvents. To clean the library's window, use the #1 wet wipe first, then the #2 dry wipe. Using touch-up paint on the housing For standalone models, a pearl-white paint kit is available for touching up nicks and scratches on the finish. [. . . ] If there are no obstructions, contact your service provider. 81 90 INVALID BLANK CONFIG. The This error applies to earlier models of the library drive blank configuration is only. Tape drives must be installed in contiguous slots, starting with the top slot. The tape drive could not be cleaned because no tape drive is installed in this location. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE QUANTUM SCALAR AIT 440




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual QUANTUM SCALAR AIT 440 will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.