User manual QUANTUM SCALAR AIT 220

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual QUANTUM SCALAR AIT 220. We hope that this QUANTUM SCALAR AIT 220 user guide will be useful to you.


QUANTUM SCALAR AIT 220 : Download the complete user guide (8040 Ko)

Manual abstract: user guide QUANTUM SCALAR AIT 220

Detailed instructions for use are in the User's Guide.

[. . . ] Scalar AIT 220 Library Installation and Operation Copyright Copyright 1998 by Advanced Digital Information Corp (ADIC). This item and the information contained herein are the property of ADIC. No part of this document may be reproduced, transmitted, transcribed, stored in a retrieval system, or translated into any language or computer language in any form or by any means, electronic, mechanical, magnetic, optical, chemical, manual, or otherwise, without the express written permission of ADIC, 11431 Willows Road N. E. , Redmond, Washington 98052. Disclaimer ADIC makes no representation or warranties with respect to the contents of this document and specifically disclaims any implied warranties of merchantability or fitness for any particular purpose. Further, ADIC reserves the right to revise this publication without obligation of ADIC to notify any person or organization of such revision or changes. Trademark Notices ADICTM, ADIC EuropeTM and ScalarTM are trademarks of Advanced Digital Information Corporation. [. . . ] The following table shows the possible states of the three LEDs and the conditions they indicate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ou may see other LED activity (random flashing, steady on, and so on). For a detailed description, refer to the tape drive product specification. 6FDODU$, 7 7DSH'ULYH2SHUDWLRQ &OHDQLQJWKHWDSHGULYHV You should clean a tape drive whenever the library displays "Drive needs cleaning" on the Main Screen of the LCD or whenever your application software notifies you. (Not all software applications display cleaning requirements. ) Regular cleaning helps ensure that the tape drives function reliably. 1RWH Some applications monitor the tape drives' cleaning needs and automatically insert the cleaning cartridge in the drive whenever it needs cleaning. If this is the case, you can skip the cleaning instructions in this section. 6HOHFWLQJFOHDQLQJFDUWULGJHV Use a Sony TCL cleaning cartridge to clean any AIT drive. To order cleaning cartridges, contact ADIC. &$87, 21 8VLQJFORWKVZDEVFRWWRQVZDEVFOHDQLQJ DJHQWVRUFOHDQLQJFDUWULGJHVQRWDSSURYHG IRU\RXUWDSHGULYHE\$', &PD\YRLGWKHWDSH GULYHZDUUDQW\ &OHDQLQJWKHWDSHGULYHIURPWKHRSHUDWRUSDQHO To clean the tape drive from the operator panel: Determine which tape drive needs cleaning by looking at the drive LEDs. The Status LED on the drive that requires cleaning will be flashing Mode 2 (the Tape LED may also be flashing Mode 2). , QVWDOODWLRQDQG2SHUDWLRQ &KDSWHU Make certain a cleaning cartridge is installed in the fixed cartridge slot. (If the fixed slot contains a data cartridge and you follow these steps, you will have to manually eject the data cartridge from the tape drive. ) If security has been enabled, disable it (see page 34). The following screen displays: C l e a n Clean Dr Dr ive ive 1 2 Select the tape drive you want to clean. Drive 1 is the tape drive closest to the magazine; Drive 2 is the tape drive farthest from the magazine. When you select a drive, the following activities occur: S The CHM picks the cleaning cartridge from the fixed slot and inserts it in the tape drive you specified. S The tape drive automatically performs the cleaning process and ejects the cartridge when the process is complete (in several minutes). S The CHM automatically picks the cartridge from the tape drive and replaces it in the fixed cartridge slot. 6FDODU$, 7 7DSH'ULYH2SHUDWLRQ Confirm that the cleaning was done by looking at the Status LED on the front of the drive. If the LED is still on, replace the cleaning cartridge and clean the tape drive again. If the LED is still on after the second cleaning, there may be a problem with the tape drive. ³ , PSRUWDQW , IWKHWDSHGULYHHMHFWVWKHFOHDQLQJ FDUWULGJHZLWKLQDPLQXWH\RXQHHGWRUHSODFHWKH FOHDQLQJFDUWULGJH6HHSDJH IRUFDUWULGJH UHSODFHPHQWLQVWUXFWLRQV When the cleaning is complete, return the library to its original control mode (SCSI Interface mode or one of the sequential modes) and re-enable security. 'LVSOD\LQJLQIRUPDWLRQDERXWWDSHGULYHV From the operator panel, you can display information about the tape drives, including the type of tape drive installed and its operational status. The information screens are updated whenever there is a change in drive status. To display tape drive information: , QVWDOODWLRQDQG2SHUDWLRQ &KDSWHU From the Main Menu, select Library Info Menu. The following screen appears: D r i v e Dr ive 1 2 Status Status Press >@ or >@to select the desired tape drive and press >(QWHU@. A Drive Status screen appears, similar to the following: DR I VE Type Present Accessible 1 STATUS : AIT 1 1 The following table describes the information in the Drive Status screen. 'ULYH6WDWXVVFUHHQ 'ULYH1 67$786 , GHQWLILHVWKHWDSHGULYHDVIROORZV 'ULYH²7KHWDSHGULYHFORVHVWWRWKHPDJD]LQH 'ULYH²7KHWDSHGULYHIDUWKHVWIURPWKHPDJD]LQH 7\SH , GHQWLILHVWKHWDSHGULYHPRGHO 1RWH, IPPDSSHDUVLWLQGLFDWHVRQHRIWKH IROORZLQJFRQGLWLRQV S No tape drive is present in that slot. S A tape drive firmware error has occurred. 3UHVHQW , QGLFDWHVZKHWKHUDWDSHGULYHLVLQVWDOOHG ²$WDSHGULYHLVQRWSUHVHQW ²$WDSHGULYHLVSUHVHQW 6FDODU$, 7 7DSH'ULYH2SHUDWLRQ 'ULYH6WDWXVVFUHHQ $FFHVVLEOH , QGLFDWHVWKHDFFHVVLELOLW\RIWKHWDSHGULYHWRWKH &+0 ² $FDUWULGJHLVORDGHGLQWKHWDSHGULYHRUWKHWDSH GULYH VVWDWXVLVXQNQRZQ ² $FDUWULGJHLVSURWUXGLQJIURPWKHWDSHGULYHRU WKH GULYHLVHPSW\ &OHDQ ² 7KHWDSHGULYHLVFOHDQ ² 7KHWDSHGULYHQHHGVWREHFOHDQHGRUWKHFOHDQLQJ WDSHLVXVHGXS :DUQLQJ 2FFXSLHG 1RWFXUUHQWO\XVHG ² 7KHUHLVQRFDUWULGJHORDGHGLQWKHWDSHGULYH ² 7KHUHLVFXUUHQWO\DFDUWULGJHORDGHGLQWKHWDSH GULYH 2FF9DOLG ² 7KHGRRUKDVEHHQRSHQHGRUVRPHRWKHU 2FFXSLHG LQWHUUXSWLRQKDVRFFXUUHGVRWKHRFFXSLHG 9DOLG LQIRUPDWLRQPD\QRWEHUHOLDEOH ² 7KHRFFXSLHGLQIRUPDWLRQLVUHOLDEOH (MHFWLQJDFDUWULGJHPDQXDOO\ If a problem occurs that requires intervention, you may need to manually eject a cartridge. The following figure shows the location of the eject button on the AIT drive. , QVWDOODWLRQDQG2SHUDWLRQ &KDSWHU BUSY TAPE STATUS EJECT BUTTON 6FDODU$, 7 S S S S 0DLQWHQDQFH This chapter describes the following: Cleaning requirements for the library Replacing the fuse Replacing the air filter Replacing the tape drives &$87, 21 8QOHVV\RXKDYHDVHOIPDLQWHQDQFHFRQWUDFW ZLWK$', &GRQRWDWWHPSWWRUHSODFHDQ\ FRPSRQHQWVLQWKHOLEUDU\RWKHUWKDQWKHWDSH GULYHVIXVHDQGDLUILOWHU, I\RXGRVR\RXZLOO YRLG\RXUZDUUDQW\ , QVWDOODWLRQDQG2SHUDWLRQ &KDSWHU &OHDQLQJUHTXLUHPHQWV The only library components that should be cleaned are the tape drives and the window in the door. Instructions for cleaning the tape drives are provided on page 59. &$87, 21 7KHOLEUDU\ VLQWHUQDOFRPSRQHQWVDUHOXEULFDWHG DWWKHIDFWRU\DQGVKRXOGQRWEHFOHDQHGRU UHOXEULFDWHG To protect the internal components from dust, keep the library door closed and locked. &OHDQLQJWKHOLEUDU\ZLQGRZ To clean the library's window, use the cleaning packet provided with the library. [. . . ] In Sequential 1 mode, the CHM moves cartridges between the slots and only one of the tape drives. 6HTXHQWLDOPRGH Sequential 1 mode provides efficient sequential operation when you have just one tape drive installed. In this mode, the CHM picks cartridges sequentially from the slots and processes them in one tape drive. (The fixed cartridge slot is not included. ) , QVWDOODWLRQDQG2SHUDWLRQ $SSHQGL[' In Sequential 1 mode, the library processes the cartridges in tape drive 1 (closest to the magazine). In Sequential 1 mode, the library performs the following steps: Picks the cartridge from slot 1 and places it in the tape drive specified by the mode (1 or 2). If the slot is empty, the CHM picks the next cartridge in the magazine. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE QUANTUM SCALAR AIT 220




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual QUANTUM SCALAR AIT 220 will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.