User manual QUANTUM PX502 QUICK START GUIDE 81-81292-03

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual QUANTUM PX502 QUICK START GUIDE 81-81292-03. We hope that this QUANTUM PX502 QUICK START GUIDE 81-81292-03 user guide will be useful to you.


QUANTUM PX502 QUICK START GUIDE 81-81292-03 : Download the complete user guide (1419 Ko)

Manual abstract: user guide QUANTUM PX502 QUICK START GUIDE 81-81292-03

Detailed instructions for use are in the User's Guide.

[. . . ] Look for the ESD sticker to identify static sensitive parts. Environmental Conditions 0 The installation site must have the following environmental conditions: · · · Humidity: 20%-80% non-condensing Temperature: 10°C-35°C (50°F-95°F) Altitude: -500 to 10, 000 feet (-152 to 3048 meters) · Avoid touching connectors and other components. NOTE: Dry climates and cold-weather heating environments have lower relative humidity and are more likely to produce static electricity. These environmental conditions apply when the PX502 tape library is in operation. NOTE: For additional specifications, refer to the Quantum PX500 Series User's Guide (PN 8181290) Unpacking the PX502 Tape Library 0 This section explains how to unpack the PX502 tape library and move it to its final installation location. If there is any damage evident on the library packaging, do not continue with the installation and contact Quantum customer support. Preparing for the Installation Before you begin the installation procedure in this section, make the following preparations as described in this section: · · Providing Necessary Tools Taking ESD Precautions 0 2 PX502 Tape Library Quick Start Guide By following these instructions, you help ensure that the system will continue to be safeguarded after it arrives at the installation site. [. . . ] Allen screws Once the location is determined, attach the back brackets to each side of the library with four M5 x 8 Allen screws (see figure 8). For example, if the measurement is 34 in. , use holes E and G. NOTE: If this is a multiple stack configuration, refer to "Multiple Library Stacks" on page 13 for information on preparing the library chassis for passing tape cartridges from one unit to another. 2 Install the library into the rack as shown in figure 9 and secure the library to the rack with four PHILLIPS screws. WARNING: The PX502 tape library weighs approximately 52 lbs (23. 6 kg). Figure 9 Installing the PX502 in the Rack PHILLIPS screws 7 PX502 Tape Library Quick Start Guide 3 Secure the back of the library to the rack with two mounting clamps and two Allen screws on each clamp. The mounting clamps are oriented differently depending on the depth of the rack (see figure 10). NOTE: If the rack depth is 27 to 30 in. , the long portion of the clamp is mounted to the back. If the rack depth is 30 to 36 in. , the long portion is mounted to the front. 4 Secure the mounting clamps to the rack rails with two PHILLIPS screws on each side (see figure 10). Figure 10 Securing the Back of the Library b Insert the tape drive(s) into the drive bay(s) slowly until the connectors are seated. Refer to figure 12 for drive bay numbering (see the Quantum PX500 Series Tape Drive Installation Instructions PN 81-81301 for information). Figure 12 Installing the Tape Drives Back of Library Tape drive 2 Tape drive 1 c Tighten the tape drive thumbscrews using a flat blade screwdriver. d Repeat these steps to install another tape drive in a different location, if desired. The first message displaying will be "Are the internal packaging materials removed?" Continue with Removing the Remaining Packing Materials 2 Connect one end of an AC power cable to each installed power supply and to a wall outlet. Removing the Remaining Packing Materials 0 Now that you have installed the library chassis and powered on the system, you MUST remove the remaining packing materials from the library chassis before the library is operational. 9 PX502 Tape Library Quick Start Guide 1 Put on an antistatic wrist strap and clip it to the library chassis. CAUTION: Take standard ESD precautions when performing this procedure. 4 Press NO to continue. The system asks you again: "Are the internal packaging materials removed?" (OK or NO). CAUTION: Pressing OK when the internal packaging restraints are in place will damage the library robotics. 2 IF there is space above the library to remove the top cover, remove the twelve PHILLIPS screws securing the top cover and FlexLink cover to gain further access to the internal packaging restraints (see figure 17). If there is no space above the PX502 library to remove the top cover, continue with Step 3. Figure 17 Removing the Top Cover (Optional Step) 5 Press NO to continue. The OCP displays "Doors opened, magazines released, pull magazines out before power shutoff. The library waits approximately 30 seconds for you to open the doors and remove both magazines from the library. NOTE: If you are unable to remove the magazines before the library shuts down. [. . . ] Preparing the library chassis for installation into a multiple library stack consists of: NOTE: It is recommended to place the Master library in the middle of the library stack for improved performance. · · Removing the FlexLink cover plates Installing the alignment hardware 1 Remove two PHILLIPS screws securing each FlexLink cover located on the top and bottom of the library using a #1 PHILLIPS screwdriver (see figure 23). NOTE: Remove the bottom FlexLink cover on every library except the bottom library in the stack. Remove the top FlexLink cover on the bottom library in the stack. p To FlexLink cover FlexLink cover To prepare the library chassis for multiple stack operation: Bo m tto Screws Remove only the bottom FlexLink cover on the top library in the stack 2 The alignment hardware installed on the top and bottom of the libraries in a multiple stack allow the FlexLink bays to align correctly when installed in a rack. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE QUANTUM PX502 QUICK START GUIDE 81-81292-03




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual QUANTUM PX502 QUICK START GUIDE 81-81292-03 will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.