User manual QUANTUM DXI6700 SITE PLANNING GUIDE

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual QUANTUM DXI6700. We hope that this QUANTUM DXI6700 user guide will be useful to you.


QUANTUM DXI6700 SITE PLANNING GUIDE: Download the complete user guide (1179 Ko)

Manual abstract: user guide QUANTUM DXI6700SITE PLANNING GUIDE

Detailed instructions for use are in the User's Guide.

[. . . ] They provide best-inclass performance with flexible, easy-to-use NAS and OST presentations as well as Ethernet and optional Fibre Channel connectivity. DXi6500 and DXi6700 appliances are part of a comprehensive set of backup solutions, serviced and supported by Quantum, the leading global specialist in backup, recovery, and archive. www. quantum. com DXi6500 and DXi6700 Site Planning Guide Included With Your DXi6500 and DXi6700 The DXi6500 and DXi6700 are fully configured to your specifications and pre-tested in the factory. Every DXi6500 and DXi6700 configuration arrives with all necessary parts included. Each system comes with an accessory kit containing rack-mount hardware and a Quick Reference and Documentation CD which includes the User's Guide. Licenses The following licenses are included with the DXi6500 and DXi6700. [. . . ] LACP configuration can be complex, and improper configuration can render your system inaccessible. Use Round Robin Where possible, use of balanced Round Robin (Mode zero) bonds is preferred for simplicity. Round Robin refers to the method used by the DXi system to balance outbound data transmission. Inbound traffic is controlled by the load balancing algorithm within the upstream Ethernet switch. Based on the switch algorithm in use, traffic observed inbound to the DXi system may or may not appear balanced. This is normal. 4 Installation DXi6500 and DXi6700 DXi6500 Segmentation Options The following network segmentation recommendations are listed in order of complexity: · Basic Network Recommendations · Intermediate Network Recommendations · Advanced Network Recommendations Basic Network Recommendations Basic network configurations do not include network segmentation, do not require switch re-configuration, and conform to the General Recommendations on page 4. No Segmentation means that data, replication, and management traffic may use the same network. If your network policies require separation of replication or management traffic, continue to the Advanced Network Recommendations on page 6. DXi6500, Model 6510 (2 x 1GbE Ports) and DXi6500, Models 6520, 6530, and 6540 (6 x 1GbE Ports) If less than 1Gb per second (~450GB/hr) of performance is required, follow these steps. Otherwise proceed to the Intermediate Network Recommendations on page 6. 3 Connect a single DXi Ethernet port (ETH0 preferred) to your switch and configure IP information appropriately on the IP page. DXi6500, Model 6550 (2 x 1GbE Ports and 2 x 10GbE Ports) -10GbE Connectivity Not Available If single 1Gb port connectivity meets requirements, follow these steps. Otherwise proceed to the Intermediate Network Recommendations on page 6. 3 Connect a single DXi 1Gb Ethernet port (ETH0 preferred) to your switch and configure IP information appropriately on the IP page. DXi6500, Model 6550 (2 x 1GbE Ports and 2x 10GbE Ports) - 10GbE Connectivity Is Available If single 10Gb connectivity is desired and meets requirements, follow these steps. Otherwise proceed to the Intermediate Network Recommendations on page 6. 3 Connect a single DXi 10Gb Ethernet port (ETH4 preferred) to your switch and configure IP information appropriately on the IP tab. Installation 5 DXi6500 and DXi6700 Site Planning Guide Intermediate Network Recommendations Intermediate network configurations do not include segmentation, but do require switch re-configuration and conform to the General Recommendations on page 4. No Segmentation means that data, replication, and management traffic may use the same network. If your network policies require separation of replication or management traffic, continue to the Advanced Network Recommendations on page 6. DXi6500, Model 6510 (2 x 1GbE Ports) and DXi6500, Models 6520, 6530, and 6540 (6 x 1GbE Ports) If multiple 1Gb port connectivity is required, follow these steps: 1 For Segmentation, select BOND ALL (Not segmented). 3 Connect multiple DXi Ethernet ports (ETH0­ETH1 for DXi6500 Model 6510, or ETH0­ ETH5 for DXi6500 Models D6520, 6530, and 6540) to your switch based on your requirements. 4 Contact your network administrator to create a Round Robin compatible Link Aggregation Group on the switch encompassing all connected ports. 2 Connect both DXi 1Gb Ethernet ports (ETH0 and ETH1) to your switch and configure IP information appropriately on the IP page. [. . . ] These characteristics and specifications are categorized as follows: · Physical Characteristics · Performance Characteristics · Environmental Specifications Note: For hard drive specifications see the appropriate hard drive product manual. Physical Characteristics The following tables provide dimensions and other physical characteristics of the DXi6500 and DXi6700 system components: · Table 4 - Physical Characteristics · Table 5 - Storage Capacity · Table 6 - Cable Drops · Table 7 - Interfaces · Table 8 - Power Requirements Table 4 Physical Characteristics Node Height Width (side to side) Depth (front to back) Weight (stand alone) Rack Space Required Air clearance 5. 2 in (13. 2 cm) 17. 2 in (43. 7 cm) 25. 5 in (64. 8 cm) 72 lbs (32. 7 kg) 3u Expansion Module 3. 5 in (8. 9 cm) 17. 2 in (43. 7 cm) 25. 5 in (64. 8 cm) 52 lbs (23. 6 kg) 2u Open 4 in (10. 2 cm) behind unit for proper air flow Table 5 Storage Capacity DXi6500 and DXi6700 Storage Capacity Usable capacity Capacity increments 8 TB to 56 TB 8 TB 12 DXi6500 and DXi6700 Specifications DXi6500 and DXi6700 Table 6 Cable Drops DXi6500 and DXi6700 Cable Drops Ethernet Cable Drops Model 6510 (2 x 1GbE ports) - 1 to 2 1GbE Ethernet connections for NAS or OST connectivity, replication, and remote management Model 6520, 6530, 6540 (6 x 1GbE ports) - 1 to 6 1GbE Ethernet connections for NAS or OST connectivity, replication, and remote management Model 6550 (2 x 1GbE ports and 2 x 10GbE ports) - 1 to 2 1GbE Ethernet connections and 1 to 2 10GbE Ethernet connections (CX4 or optical) for NAS or OST connectivity, replication, and remote management DXi6700 (2 x 1GbE ports) - 1 to 2 1GbE Ethernet connections for replication and remote management Fibre Channel Drops Model 6540, 6550 (2 x FC ports) - 1 to 2 Fibre Channel connections for path-to-tape connection DXi6700 (4 x FC ports) - 1 to 4 Fibre Channel connections for VTL data backup and path-to-tape connection Power Outlets Node - 2 USA type 3-prong power outlets or 2 Continental Europe type 2prong power outlets Expansion Module (each) - 2 USA type 3-prong power outlets or 2 Continental Europe type 2-prong power outlets Table 7 Interfaces DXi6500 and DXi6700 Interfaces Interfaces DXi6500 NAS backup target: 128 shares maximum (NFS or CIFS) DXi6500 OST backup target: 100 storage servers maximum DXi6700 Number of Virtual Drives: 40 standard, 80 maximum DXi6700 Number of Partitions: 64 maximum DXi6500 and DXi6700 Specifications 13 DXi6500 and DXi6700 Site Planning Guide Hardware Model 6510 2 ports 10/100/1000 BaseT Ethernet (RJ45 connector) Model 6520, 6530 6 ports 10/100/1000 BaseT Ethernet (RJ45 connector) Model 6540 6 ports 10/100/1000 BaseT Ethernet (RJ45 connector) and 2 ports 8Gb Fibre Channel (LC connector) Model 6550 2 ports 10/100/1000 BaseT Ethernet (RJ45 connector), 2 ports 10, 000 BaseT Ethernet (CX4 connector or optical LC connector), and 2 ports 8Gb Fibre Channel (LC connector) DXi6700 2 ports 10/100/1000 BaseT Ethernet (RJ45 connector) and 4 ports 8Gb Fibre Channel (LC connector) Table 8 Power Requirements DXi6500 and DXi6700 Power Requirements Power Supplies and Cords Node Two (2) hot swappable redundant power supplies Two (2) USA type 3-prong power cords with IEC320 C13 connectors Two (2) Continental Europe type 2-prong power cords with CEE7 connectors Expansion Module Two (2) hot swappable redundant power supplies Two (2) USA type 3-prong power cords with IEC320 C13 connectors Two (2) Continental Europe type 2-prong power cords with CEE7 connectors Voltage Node Expansion Module Frequency Node Expansion Module Average AC Current Node Expansion Module 100­240 VAC 100­240 VAC 50­60Hz 50­60Hz 570 Watts, 5. 7 @ 100 VAC, 1945 BTU/hr 570 Watts, 2. 4A @ 240 VAC, 1945 BTU/hr 230 Watts, 2. 3A @ 100 VAC, 785 BTU/hr 230 Watts, 1. 0A @ 240 VAC, 785 BTU/hr 14 DXi6500 and DXi6700 Specifications DXi6500 and DXi6700 Inrush Peak AC Current Node Expansion Module 1100 Watts, 11. 0A @ 100 VAC 1120 Watts, 4. 7A @ 240 VAC 300 Watts, 3. 0A @ 100 VAC 420 Watts, 1. 75A @ 240 VAC Caution: To safeguard backups in the event of a power outage, Quantum recommends that you connect the DXi6500 or DXi6700 to a UPS (uninterruptable power supply). Performance Characteristics Table 9 lists the performance characteristics of the DXi6500 and DXi6700 system. Table 9 Performance Characteristics Performance Characteristics DXi6500 and DXi6700 Product family Adaptive ingest performance of up to 3. 5 TB/hour (depending on model) DXi6500 and DXi6700 Specifications 15 DXi6500 and DXi6700 Site Planning Guide Environmental Specifications Table 10 provides various DXi6500 and DXi6700 environmental specifications. Table 10 Environmental Specifications Climatic Environment Temperature Operating Shipping and storage Relative humidity Operating Shipping and storage Altitude Operating Shipping and storage Vibration and Shock Operational Shock Peak Acceleration Duration Wave Shape Operational Vibration Mode Frequency Range Amplitude Rate/Duration Application Shipping and Storage Mode Frequency Range Amplitude Rate/Duration Acoustic Acoustic output Agency Approvals Safety Emissions IEC 60950-1 (ed. 1), CSA 60950-1-03/UL 60950-1 1st Edition EN55022 Class A, FCC Part 15 Class A, ICES-003 Class A, VCCI Class A, CISPR 22 Class A, CNS13438 Class A, KN22 Class A Operating < 67 dBA at 1 meter, room temperature (20C) 3G 8 milliseconds ½ Sine Swept frequency 20Hz­300Hz 0. 25G 0. 75 octaves/minute X, Y, and Z axes Random Vibration 4Hz­300Hz 0. 96 Grms (PSD can be provided) 30 minutes X, Y, Z axes 10° to 35°C (50° to 95°F) up to 3048m (10, 000 ft) ­20° to 60°C (­4° to 140°F) up 12, 000m (39, 370 ft) 20% to 80% (non-condensing) 5% to 95% (non-condensing) ­30m to 3048 m (­100 to 10, 000 ft) ­30m to 12, 000 m (­100 to 39, 370 ft) 16 DXi6500 and DXi6700 Specifications DXi6500 and DXi6700 Immunity EN55024/KN24: EN 61000-3-2 - Harmonic current emissions test EN 61000-3-3 - Voltage fluctuations and flicker in low-voltage supply systems test EN 55024:1998 - Information technology equipment - Immunity characteristics - Limits and methods of measurements EN 61000-4-2 - Electrostatic discharge immunity test EN 61000-4-3 - Radiated, radio-frequency, electromagnetic field immunity test EN 61000-4-4 - Electrical fast transient/burst immunity test EN 61000-4-5 - Surge immunity test EN 61000-4-6 - Immunity to conducted disturbances, induced by radio-frequency fields EN 61000-4-8 - Power frequency magnetic field immunity test EN 61000-4-11 - Voltage dips, short interruptions and voltage variations immunity test Caution: The DXi6500 and DXi6700 system are designed to be installed in a rack enclosure. Ensure that the operating temperature inside the rack enclosure does not exceed the maximum rated ambient temperature. Do not restrict air flow to the DXi6500 and DXi6700 components. DXi6500 and DXi6700 Specifications 17 DXi6500 and DXi6700 Site Planning Guide *6-66638-02* 18 6-66638-02 Rev D, August 2010 For assistance, contact the Quantum Customer Support Center: USA: 800-284-5101 (toll free) or 949-725-2100 EMEA: 00800-4-782-6886 (toll free) or +49 6131 3241 1164 APAC: +800 7826 8887 (toll free) or +603 7953 3010 Worldwide: http://www. quantum. com/ServiceandSupport About Quantum Preserving the World's Most Important Data. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE QUANTUM DXI6700




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual QUANTUM DXI6700 will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.