User manual QUANTUM DXI6500 SITE PLANNING GUIDE

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual QUANTUM DXI6500. We hope that this QUANTUM DXI6500 user guide will be useful to you.


QUANTUM DXI6500 SITE PLANNING GUIDE: Download the complete user guide (1063 Ko)

Manual abstract: user guide QUANTUM DXI6500SITE PLANNING GUIDE

Detailed instructions for use are in the User's Guide.

[. . . ] Each system comes with an accessory kit containing rack-mount hardware and a Quick Reference and Documentation CD which includes the User's Guide. Licenses The following licenses are included with the DXi6500. Some licenses are pre-installed and some are included on license certificates, as noted below. (License key is preinstalled on all DXi6500 models. ) · NAS - Exposes NAS interface to host. (License key is pre-installed on all DXi6500 models. ) · Replication - Enables replication capability. [. . . ] Each traffic type (Data, Management, and Replication) requires a set of network settings. (3 IP addresses required) · ETH0 (Replication), ETH1 (Management/Data) - All Replication traffic takes place on port ETH0. Each traffic type (Data, Management, and Replication) requires a set of network settings. (3 IP addresses required) · ETH0 (Management), ETH1 (Replication/Data) - All Management traffic takes place on port ETH0. Each traffic type (Data, Management, and Replication) requires a set of network settings. (3 IP addresses required) · ETH1 (Data), ETH0 (Replication/Management) - All Data traffic takes place on port ETH1. Each traffic type (Data, Management, and Replication) requires a set of network settings. (3 IP addresses required) DXi6500 - Models 6520, 6530, 6540 (6 x 1GbE ports) · BOND ALL (Not segmented) - All ports (ETH0, ETH1, ETH2, ETH3, ETH4, and ETH5) are bonded together and require a single set of network settings. (1 IP address required) Note: Not segmented (Bond All) is the default configuration. 4 Installation DXi6500 · BOND ALL (Replication/Management/Data) - All ports (ETH0, ETH1, ETH2, ETH3, ETH4, and ETH5) are bonded together for all traffic types. Each segment (Data, Management, and Replication) requires a set of network settings. (3 IP addresses required) · ETH0 (Replication), BOND ALL-1 (Management/Data) - All Replication traffic takes place on port ETH0. Data and Management traffic take place on ports ETH1, ETH2, ETH3, ETH4 and ETH5. Each segment (Data, Management, and Replication) requires a set of network settings. (3 IP addresses required) · ETH0 (Management), BOND ALL-1 (Replication/Data) - All Management traffic takes place on port ETH0. Data and Replication traffic take place on ports ETH1, ETH2, ETH3, ETH4 and ETH5. Each segment (Data, Management, and Replication) requires a set of network settings. (3 IP addresses required) · BOND ALL-1 (Data), ETH0 (Replication/Management) - All Data traffic takes place on ports ETH1, ETH2, ETH3, ETH4 and ETH5. Each segment (Data, Management, and Replication) requires a set of network settings. (3 IP addresses required) DXi6500 - Model 6550 (2 x 1GbE ports and 2 x 10GbE ports) · BOND ALL 1GB (Not segmented) - Both 1GbE ports (ETH0 and ETH1) are bonded together and require a single set of network settings. (The 10GbE ports are not used in this configuration. ) (1 IP address required) · BOND ALL 10GB (Not segmented) - Both 10GbE ports (ETH4 and ETH5) are bonded together and require a single set of network settings. (The 1GbE ports are not used in this configuration. ) (1 IP address required) Note: Not segmented (Bond All) is the default configuration. · BOND ALL 1GB (Replication/Management/Data) - Both 1GbE ports (ETH0 and ETH1) are bonded together for all traffic types. [. . . ] Replication is asynchronous, one-to-one or multiple-to-one configurations; shares in same unit act as replication source or target; units with shares acting as replication targets can also support local backup. DXi6500 Specifications 11 DXi6500 Site Planning Guide Table 8 Power Requirements DXi6500 Power Requirements Power Supplies and Cords Node Two (2) hot swappable redundant power supplies Two (2) USA type 3-prong power cords with IEC320 C13 connectors Two (2) Continental Europe type 2-prong power cords with CEE7 connectors Expansion Module Two (2) hot swappable redundant power supplies Two (2) USA type 3-prong power cords with IEC320 C13 connectors Two (2) Continental Europe type 2-prong power cords with CEE7 connectors Voltage Node Expansion Module Frequency Node Expansion Module Average AC Current Node Expansion Module Inrush Peak AC Current Node Expansion Module 100­240 VAC 100­240 VAC 50­60Hz 50­60Hz 570 Watts, 5. 7 @ 100 VAC, 1945 BTU/hr 570 Watts, 2. 4A @ 240 VAC, 1945 BTU/hr 230 Watts, 2. 3A @ 100 VAC, 785 BTU/hr 230 Watts, 1. 0A @ 240 VAC, 785 BTU/hr 1100 Watts, 11. 0A @ 100 VAC 1120 Watts, 4. 7A @ 240 VAC 300 Watts, 3. 0A @ 100 VAC 420 Watts, 1. 75A @ 240 VAC Caution: To safeguard backups in the event of a power outage, Quantum recommends that you connect the DXi6500 to a UPS (uninterruptable power supply). Performance Characteristics Table 9 lists the performance characteristics of the DXi6500 system. 12 DXi6500 Specifications DXi6500 Table 9 Performance Characteristics Performance Characteristics DXi6500 Product family Adaptive ingest performance of up to 2. 0 TB/hour (depending on model) Environmental Specifications Table 10 provides various DXi6500 environmental specifications. Table 10 Environmental Specifications Climatic Environment Temperature Operating Shipping and storage Relative humidity Operating Shipping and storage Altitude Operating Shipping and storage Vibration and Shock Operational Shock Peak Acceleration Duration Wave Shape Operational Vibration Mode Frequency Range Amplitude Rate/Duration Application Shipping and Storage Mode Frequency Range Amplitude Rate/Duration 3G 8 milliseconds ½ Sine Swept frequency 20Hz­300Hz 0. 25G 0. 75 octaves/minute X, Y, and Z axes Random Vibration 4Hz­300Hz 0. 96 Grms (PSD can be provided) 30 minutes X, Y, Z axes 10° to 35°C (50° to 95°F) up to 3048m (10, 000 ft) ­20° to 60°C (­4° to 140°F) up 12, 000m (39, 370 ft) 20% to 80% (non-condensing) 5% to 95% (non-condensing) ­30m to 3048 m (­100 to 10, 000 ft) ­305m to 12, 000 m (­1, 000 to 39, 370 ft) DXi6500 Specifications 13 DXi6500 Site Planning Guide Acoustic Acoustic output Agency Approvals Safety Emissions Immunity IEC 60950-1 (ed. 1), CSA 60950-1-03/UL 60950-1 1st Edition EN55022 Class A, FCC Part 15 Class A, ICES-003 Class A, VCCI Class A, CISPR 22 Class A, CNS13438 Class A, KN22 Class A EN55024/KN24: EN 61000-3-2 - Harmonic current emissions test EN 61000-3-3 - Voltage fluctuations and flicker in low-voltage supply systems test EN 55024:1998 - Information technology equipment - Immunity characteristics - Limits and methods of measurements EN 61000-4-2 - Electrostatic discharge immunity test EN 61000-4-3 - Radiated, radio-frequency, electromagnetic field immunity test EN 61000-4-4 - Electrical fast transient/burst immunity test EN 61000-4-5 - Surge immunity test EN 61000-4-6 - Immunity to conducted disturbances, induced by radio-frequency fields EN 61000-4-8 - Power frequency magnetic field immunity test EN 61000-4-11 - Voltage dips, short interruptions and voltage variations immunity test Caution: The DXi6500 system is designed to be installed in a rack enclosure. Ensure that the operating temperature inside the rack enclosure does not exceed the maximum rated ambient temperature. Operating < 67 dBA at 1 meter, room temperature (20C) *6-66638-02* 14 6-66638-02 Rev A, February 2010 For assistance, contact the Quantum Customer Support Center: USA: 800-284-5101 (toll free) or 949-725-2100 EMEA: 00800-4-782-6886 (toll free) or +49 6131 3241 1164 APAC: +800 7826 8887 (toll free) or +603 7953 3010 Worldwide: http://www. quantum. com/ServiceandSupport About Quantum Backup. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE QUANTUM DXI6500




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual QUANTUM DXI6500 will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.