User manual QUANTUM DXI2500-D QUICK START GUIDE REV B

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual QUANTUM DXI2500-D. We hope that this QUANTUM DXI2500-D user guide will be useful to you.


QUANTUM DXI2500-D QUICK START GUIDE REV B: Download the complete user guide (2772 Ko)

You may also download the following manuals related to this product:

   QUANTUM DXI2500-D REV A01 (5874 ko)
   QUANTUM DXI2500-D SITE PLANNING GUIDE REV A01 (1000 ko)

Manual abstract: user guide QUANTUM DXI2500-DQUICK START GUIDE REV B

Detailed instructions for use are in the User's Guide.

[. . . ] Also, the DXi2500-D system must be installed only by qualified IT personnel. This is required to prevent untrained personnel from allowing body parts or electrically conductive items to penetrate into the interior of the system. Note: For more information about the CSA C22. 2 / UL 60950 specification, or to obtain a copy, see http://www. csa. ca. For more information about the EN 60950-1 specification, see http://www. cenelec. eu. [. . . ] Note: Use the retainer brackets on the back of the power supplies to provide strain relief for the power cables. See Cabling the DXi2500-D System on page 16. 4 Route the cables along the bend in the cable-management arm. 5 Adjust the cable slack as needed at the hinge position and secure the cables with the tie wraps (see figure 10). 7 Slide the system in and out of the rack to verify that the cables are routed correctly and do not bind, stretch, or interfere with the movement of the cable-management arm. Adjust the cable positioning inside the cable-management arm as needed. Note: If you pull the system out to its furthest extension, the slide assemblies will lock in the extended position. To release the lock, press the slide release latch on the side of each slide and then slide the system into the rack. Installing the DXi2500-D System 13 DXi2500-D Quick Start Guide 8 When you are satisfied that the cables are routed correctly, push the system fully into the rack. Attaching the CableManagement Arm Ramp Assembly 0 The cable-management arm ramp assembly guides the cable-management arm into a stable, level position. To attach the cable-management arm ramp assembly: 1 Select only one ramp assembly, depending on the orientation of the cablemanagement arm. a If the cable-management arm is attached on the right side of the rack (as shown in figure 12), attach the left cable-management arm ramp assembly to the rack (see figure 11). If the cable-management arm is attached on the left side of the rack, attach the right cable-management arm ramp assembly to the rack (see figure 11). The cable-management arm ramp assembly must be installed to prevent long-term sagging of the cable-management arm. b Caution: Note: Ensure that you use the cable-management arm ramp assembly with the metal ramp facing toward the center of the rack (see figure 11). The orientation shown in figure 11 presumes you are facing the back of the system. Note: Figure 11 Orientation for the Cable-Management Arm Ramp Assembly 2 1 3 1 left cable-management arm ramp assembly 2 right cable-management arm ramp assembly 3 metal ramp 2 Fit the latch of the ramp assembly on the ramp assembly bracket, located on the opposite side of the rack from where you attached the cable-management arm (see Figure 1-11). 3 To slide the cable-management arm into place: a b Locate the ramp assembly wireform guide at the bend of the cable-management arm. Lift and slide the ramp assembly wireform guide up the ramp, stopping at the ramp assembly seating catch. Installing the DXi2500-D System 14 DXi2500-D c If you have selected the correct ramp assembly, the wireform guide will seat correctly in the catch at the top of the ramp assembly each time the system is cycled in the rack. figure 12 shows the left ramp assembly installed with the cablemanagement arm attached on the right. To disengage the cable-management arm ramp assembly, press the ramp assembly release button on the ramp assembly latch and pull the ramp assembly off the bracket (see figure 12). Note: In figure 12, the cable-management arm is attached on the right side of the rack and the left cable-management arm ramp assembly is attached to the left side of the rack. Conversely, if you attach the cable-management arm on the left side of the rack, attach the right cable-management arm ramp assembly to the right side of the rack. Figure 12 Installing the CableManagement Arm Ramp Assembly 1 2 3 4 5 6 1 4 ramp assembly bracket ramp assembly seating catch 2 5 cable-management arm ramp assembly latch left cable-management arm ramp assembly 3 6 ramp assembly release button ramp assembly wireform guide Installing the DXi2500-D System 15 DXi2500-D Quick Start Guide Cabling the DXi2500-D System To connect the power and Ethernet cables to the DXi2500-D: 1 Connect the Ethernet cables to ports 0 and 1 on the back of the DXi2500-D system (see figure 13). 0 Figure 13 Connecting the Ethernet Cables Connect Ethernet cables 2 Connect the power cables to the back of the DXi2500-D system (see figure 14). Figure 14 Connecting the Power Cables 3 Attach the power cord retention bracket on the right bend of the power supply handle (see figure 15). Bend the system power cable into a loop as shown in the illustration and attach to the bracket's cable clasp. Repeat the procedure for the second power supply. 16 Installing the DXi2500-D System DXi2500-D Figure 15 Installing the Power Cord Retention Bracket 4 Plug the other end of the power cables into a grounded electrical outlet or a separate power source such as an uninterruptable power supply (UPS) or a power distribution unit (PDU). Caution: To safeguard backups in the event of a power outage, Quantum recommends that you connect the DXi2500-D to a UPS (uninterruptable power supply). 5 (Optional) Install the bezel (see figure 15). Affix the Quantum DXi2500-D badge to the lower left corner of the bezel to help you identify the system. Note: You must remove the bezel to power on or power off the system. Figure 16 Installing the Bezel Installing the DXi2500-D System 17 DXi2500-D Quick Start Guide Initial Setup Before the DXi2500-D is operational, you must configure the system by completing the remote management setup pages. [. . . ] In the Domain/Workgroup Name box, type the name of the Windows workgroup to join. Click Yes to confirm, then click OK to continue. 3 Create a de-duplicated NAS share: a b From the Disk Backup page, click the NAS tab. The Add NAS Share page displays (see figure 24). 24 Initial Setup DXi2500-D Figure 24 Add NAS Share Page c d e f In the Name box, type a name for the NAS share. The NAS share is created and becomes available on the Windows network. 4 To configure your backup application to begin performing backups to the new NAS share, refer to your backup application documentation. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE QUANTUM DXI2500-D




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual QUANTUM DXI2500-D will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.