User manual QUANTUM DX5000

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual QUANTUM DX5000. We hope that this QUANTUM DX5000 user guide will be useful to you.


QUANTUM DX5000 : Download the complete user guide (2071 Ko)

Manual abstract: user guide QUANTUM DX5000

Detailed instructions for use are in the User's Guide.

[. . . ] This is required to prevent untrained personnel from allowing body parts or electrically conductive items to penetrate into the interior of the system when replacing or installing drives, fans, and power supplies. When choosing an installation site for the DX3000/DX5000 system, consider the following requirements: · · Rack Space Requirements Environmental Conditions Providing Necessary Tools 0 Provide the following tools for unpacking and installing the DX3000 and DX5000 systems: · · #1 PHILLIPS® screwdriver #2 PHILLIPS screwdriver #1 Flat head screwdriver Antistatic wrist strap included in accessory kit Rack Space Requirements 0 · · Table 1 contains the rack requirements for both the DX3000 and DX5000. Taking ESD Precautions Table 1 Rack Requirements DX3000 Depth Width Height Weight Air Clearance 27 in (68. 6 cm) 19 in (48. 3 cm) 3. 5 in (8. 9 cm), 2U 50 lbs (22. 68 kg) DX5000 25. 4 in (64. 5 cm) 19 in (48. 3 cm) 8. 75 (22. 2 cm), 5U · 122 (55. 34 kg) · · 0 Some components within the DX3000 and DX5000 systems contain static-sensitive parts. To avoid damaging these parts while performing installation procedures, always observe the following precautions: · Keep the DX3000/DX5000 system turned off during all installation procedures. Keep static-sensitive parts in their original shipping containers until ready for installation. [. . . ] The weight of the chassis may cause the rack to become "top heavy" and unstable if installed in the top of an empty rack. NOTE: Quantum ships sufficient clip nuts to support mounting the DX3000/DX5000 rack rails and also to secure the front of the chassis to the rails. Clip nut 4 DX3000 and DX5000 Quick Start Guide Figure 5 Assembling the Rack Rails DX5000: Front mounting bracket preset. Ensure the screws are in the correct position. kr ail s · DX5000 - Two 10-32 x . 50 in. PHILLIPS screws on each rail at the front and back of the rack for the DX5000. DX 50 00 rac NOTE: Ensure that clip nuts are installed on the rails (see figure 4) prior to installing the DX5000 rails. Figure 6 Installing the Chassis Support Brackets (DX3000 and DX5000) 10-32 x . 50 PHILLIPS screws DX5000: Adjustment screws; adjusts to the depth of your rack Clip nuts DX3000: Bracket (short brackets pre installed) DX 30 00 r DX5000 support brackets ac k rai ls DX3000: The brackets are secured with four #8 PHILLIPS screws and four nuts. 2 Install the left and right chassis support brackets at the beginning of a hole pattern (see Locating the Mounting Position) and secure as follows (see figure 6): NOTE: The support brackets extend to accommodate rack depths or 30 to 36 in. Slotted screw with and a three hole nut plate on each rail at the front and back of the rack. PHILLIPS screws and nuts are also provided for racks with threaded holes. DX3000 support brackets 10-32 x . 50 slotted screw Three hole nut plate, use bottom hole 3 Once the rails are secured to the rack, tighten the rail adjustment nuts on each rail. 4 With the support brackets installed, prepare the chassis mounting holes if necessary (see figure 7 for hole location). These are the holes used to secure the chassis to the rack. NOTE: The DX3000 support brackets must be installed on the inside rack rails. 5 DX3000 and DX5000 Quick Start Guide Figure 7 DX3000/DX5000 Chassis Mounting Holes Figure 8 Securing the DX3000/ DX5000 Chassis to the Rack Chassis mounting holes DX5000 chassis 5 DX 00 up 0s r po t ke ac br t Chassis mounting holes DX 00 30 et ck ra b rt po up s DX3000 chassis 5 Carefully slide the chassis into the rack. WARNING: The DX3000 weighs 38 lbs (17. 24 kg) and the DX5000 weights 85 lbs (38. 56 kg) without hard drives. 6 Secure the DX3000/DX5000 chassis to the rack with the following hardware (see figure 8): · DX3000 - two 10-32 x 1. 25 in. (M5 x 32 metric also provided) black PHILLIPS screws on each side of the front of the chassis. (M5 x 32 metric also provided) black PHILLIPS screws on each side of the front of the chassis. 10-32 in. (M5) screws Clip nuts, installed in step 4 7 Install each of the hard drive sleds into the DX-Series storage array chassis. Ensure each drive is completely installed in the chassis with the drive handle in the closed position (see figure 9 for DX3000 and figure 10 for DX5000). CAUTION: Use ESD procedures when handling the hard drives sleds (see "Taking ESD Precautions" on page 2). Place the ESD wrist strap on your wrist and connect the other end of the strap to the DX3000/DX5000 chassis. · 6 DX3000 and DX5000 Quick Start Guide NOTE: The hard drives must be installed in the proper sequence since RAID sets have already been established at the factory. Refer to the label on the bottom of the drive sled for the drive number. The hard drive numbering starts in the lower left-hand drive bay and then moves to the right. Drive 4 DX3000 Drive 0 Drive 5 Drive 1 Drive 6 Drive 2 Drive 7 Drive 3 Figure 10 Installing the Disk Drives in the DX5000 Chassis Array controller 2 Array controller 1 Dr ive Dr iv 0 Drive 8 Array controller 2 Drive 4 Drive 0 Array controller 1 Drive 4 DX5000 Drive 0 Drive 8 Drive 9 Drive 5 Drive 1 Drive 9 Drive 5 Drive 1 Drive 10 Drive 11 Drive 6 Drive 2 Drive 7 Drive 3 e0 Dr ive 11 Drive 10 Drive 11 Drive 6 Drive 2 Drive 7 Drive 3 Dr ive 11 Figure 9 Installing the Disk Drives in the DX3000 Chassis The DX3000/DX5000 chassis is now installed in the rack. Dr iv e Dr iv e Cabling the DX3000/DX5000 4 Dr ive 5 Dr ive ive 1 6 0 0 Dr The cabling instructions differ depending on the system installed. [. . . ] The number of cartridges decreases with higher capacity per cartridge. 13 Enter the starting cartridge barcode. NOTE: The barcode format must be AANNNN, where A is any uppercase alpha-numeric character and N is any single digit (0-9). Barcodes automatically increment. United States of America Quantum Corporation 141 Innovation Drive Irvine, CA 92612 U. S. A. phone 949. 856. 7800 fax 949. 856. 7799 European Headquarters Quantum Corporation 3 Bracknell Beeches Old Bracknell Lane West Bracknell Berkshire RG12 7BW United Kingdom phone +44 1344 353500 fax +44 1344 353510 Asia Pacific Quantum Corporation 9 Temasek Boulevard, #08-03 Suntec Tower Two Singapore 038989 Tel: +65 6334 0660 Fax: +65 6432 2830 Email: singapore. sales@quantum. com ©2006 Quantum Corporation. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE QUANTUM DX5000




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual QUANTUM DX5000 will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.