[. . . ] AML Management Unit
Reference Guide
Version 3. 12 Document Number: 6-00440-02
Copyright Notice
© 2003 ADIC The information contained in this document is subject to change without notice. This document contains proprietary information which is protected by copyright. No part of this document may be photocopied, reproduced, or translated to another language without prior written consent of ADIC. ADIC shall not be liable for errors contained herein or for incidental or consequential damages (including lost profits) in connection with the furnishing, performance or use of this material whether based on warranty, contract, or other legal theory. [. . . ] Reset scanner communication Command line for input of CRT commands (see Documentation for AML/J components) Send commands listed in Patch Command Line to Scanner
5-26
6-00440-02
AMU
Gripper test
Command
Gripper test
Field
Test sensors and motors on gripper. Figure 5-29
Explanation
Window "PMac Gripper Test Dialog"
Sensor status
Possible status of gripper sensors: · red = sensor active · green = sensor inactive · yellow = no information Gripper sensors displayed: · Crash sensor · Bow forward (query pin) · Bow backward (query pin) · Teach sensor
Gripper status
Display signals for gripper motors (stepper motors axis B and C) · Gripper prog. · Gripper sensor · Turn sensor · Gripper Init - Re-reference gripper motors · Teach on/off - Switch on/off reflected light sensor (= teach sensor) · Gripper teach - Close gripper jaws to allow light beam of teach sensor to hit teach labels · Gripper 0°/90°/180°/270° - Turn gripper (axis C) to angle selected
Gripper functions
PMMaint
5-27
AMU
Medium
The selection of the medium corresponds to the opening/closing stroke of the gripper. · Open Gripper - Open gripper · Close Gripper -Close gripper Clear Log window
Clear
Menu Teach
Figure 5-30 Menu "Teach"
Teach Devices
Teach command with the same functions of the teach command available on the AMU operating console. Program PMMaint · · start KRN/P from AMU send commands to KRN/P Window "PMac Kernel Teach Dialog"
Figure 5-31
Command
Teach Box
Field
Device: Type - Name
Explanation
Select component to teach (from all components defined in the Graphical Configuration - file "AMUCONF. INI"). Row Pos.
Explanation
Select segment in storage tower (always 1 on AML/J, exception I/O unit/D (HICAP): 1 or 2) not used not used
Speed %
Speed for teach. Reduce the speed if you are not sure if the teach coordinate is correct.
Cmd. Delay
Wait time between clicking on field Execute and execution of the command by the robot. Command delay is useful in larger systems.
Recv KrnP
Log window for display of data exchange with KRN/P of AMU New Teach Reteach a component (AMU-Option 1N). · Values existing for this component in file KrnRefPt. R00 will be deleted. · From the basic teach coordinate (AMUCONF. INI) the robot determines the coordinate of all required teach points of the component. · On the basis of the teach point file KrnRefPt. R00 the robot defines the coordinates of all required teach points. Reset · Reset contents of Log window · Prepare window for start of new command Reset does not reset the command processing by the PMAC board.
PMMaint
5-29
AMU
Setup new Drives
Command
Setup new Drives
Field
Set up handling of drives. Figure 5-32
Explanation
Window "PMAC Setup new Drives Dialog"
Drive Trace
Select drive defined in the Graphical Configuration. The communications window PMAC Trace Dialog opens when you click here: Figure 5-33 Window "PMAC Trace Dialog"
5-30
6-00440-02
AMU
Command
Field
PVar
Explanation
PVAR values are displayed when you click here. Figure 5-34 Window "PMAC PVAR Dialog"
Offset
The offset values in AMUCONF. INI or AMUCONST. INI are displayed when you click here: Figure 5-35 Window "PMAC Offset Dialog"
You can also change offsets in the AMUCONF with Adjust Handling (refer to Adjust Handling on page 5-33). The X, Y, and Z coordinates in AMUCONF. INI or KRNREFPT. R00 are displayed when you click here: Figure 5-36 Window "PMAC Coordinate Dialog"
Change teach coordinates in AMUCONF with Initial Teach (refer to Initial Teach on page 5-21). Change teach coordinate in KRNREFPT with Teach Devices (refer to Teach Devices on page 5-28). axis Select axis to be moved.
PMMaint
5-31
AMU
Command
Field
mm/step action
Explanation
Select step width (in mm/step). · Get: get medium from drive · Put: put medium into drive · Disc: press eject button Set offsets of Get and Put to the same value. - Start movement for Get/Put/Disc · CLOSE- Close gripper for Get · OPEN - Open gripper for Put Direction of movement in room coordinates. · REGRIP (refer to PMAC PVAR DIalog on page 5-32) · MDIST (refer to PMAC PVAR DIalog on page 5-32) Save parameters found to PMAC board (P500. . P699) AMUCONF. INI (Offsets)
Join Offset New Drive
GO!/CLOSE GO!/OPEN
move +/regrip? [. . . ] The logical archive (archive catalog) is the list of volsers assigned to the compartments in the physical archive. Contains the assignment of volsers to the compartments in the physical archive as well as further vital information about the media and the drives. Label on the medium, contains the volser in a form readable for the robot (barcode). Command, instruction sent to the AML system: · from the host computer · direct operator input at the AMU operating console Definition of the AML system. [. . . ]