[. . . ] Quantum|ATL 7100 Series Library
Operator's Guide
6241102-02
Ver. 2
Quantum|ATL 7100 Series Library Operator's Guide, 6241102-02, Ver. provides this publication "as is" without warranty of any kind, either express or implied, including but not limited to the implied warranties of merchantability or fitness for a particular purpose. Quantum|ATL is the generally known alternative designation of ATL Products, Inc. [. . . ] In this situation, you can load or unload the cartridges through the storage array door.
Caution:
DO NOT USE CompacTape I, CompacTape IIor CompacTape IIIXT tape cartridges in this library.
To bulk load or unload cartridges through the storage array door:
1 If loading cartridges, verify all cartridges have a bar code label. Note:
Use the bar code labels provided with the library.
2 If the library is powered on, press the control panel STANDBY
button. The library robotics will stop after completing the current command(s). Verify that System Off-line is displayed in the SDA.
3 Open the storage array door. When loading
a cartridge, insert the cartridge in the proper orientation (see figure 10, bar code label facing out and on the left side).
20
Quantum|ATL 7100 Series Library Operator's Guide
Chapter 2 Operating the Library Operating Procedures
Figure 12 Tape Cartridge Orientation
Quantum|ATL 7100 Series Library Operator's Guide
21
Chapter 2 Operating the Library Operating Procedures
Note:
The load port bins are keyed to ensure that tape cartridges are inserted in the proper orientation. Fixed storage array bins inside the library, however, are not keyed, and you MUST ensure that cartridges are loaded in the proper orientation.
5 When finished, close the storage array door. 6 Press the control panel STANDBY button, and verify that
System On-line is displayed in the SDA.
Turning the Interior Light On or Off 2
The library is normally shipped with the interior light set to the On position. Use the following procedure to turn the interior light on or off.
Note:
The interior light bulb is not an operator-replaceable item. If the light bulb needs replacement, notify your field service engineer.
1 Press the control panel STANDBY button. The library robotics
will stop after completing the current command(s). Verify that System Off-line is displayed in the SDA.
2 Open the front door by pulling the door towards you. (The
door opens to your right. )
3 Reach through the front door and set the light switch on the far
side of the light to the desired position (see figure 13).
4 Close and latch the library front door. 5 Press the control panel STANDBY button, and verify that
System On-line is displayed in the SDA.
22
Quantum|ATL 7100 Series Library Operator's Guide
Chapter 2 Operating the Library Using the Control Panel Menus
Figure 13 Turning the Interior Light On/Off
Interior light
Power switch
(opens to right)
Using the Control Panel Menus
Entering Menu Mode
2
To enter menu mode: 2
1 Press the control panel STANDBY button, and verify the SDA
displays System Off-line.
2 Press the SELECT button to enter menu mode. Verify the
following is displayed in the SDA:
Quantum|ATL 7100 Series Library Operator's Guide
23
Chapter 2 Operating the Library Using the Control Panel Menus
Menu: Configuration
Menu Navigation 2
In menu mode, the Status Display Area (SDA) displays two lines:
Line 1 Line 2
The upper line (line 1) of the display is passive. The lower line (line 2) is the active line and shows the items that can be selected from the current menu. When you press the "up arrow" () and "down arrow" () buttons, line 2 scrolls through the options available for the current menu. When you press the SELECT button, the submenu or function displayed on line 2 is selected or executed. There is an Exit option at the end of each menu, submenu and option list. It shows the commands and associated SDA displays involved in changing the "Auto Clean" option from "Disabled" (factory default) to "Enabled. "
Exiting Menu Mode
2
There are two ways to exit from menu mode: · · Conventional method Fast method
24
Quantum|ATL 7100 Series Library Operator's Guide
Chapter 2 Operating the Library Using the Control Panel Menus
Figure 14 Menu Structure
Main Menu
Configuration Inquiry SCSI Address Power-Up State Num of Drives Auto Clean Retries Auto Load Language Set View Auto Inventory No Barcode Scan Emulate Exabyte 4/52 Identity Temperature Det Exit Menu
Drive Control Unload Clean Exit Menu
Calibration Cal All Cal Storage Cal Drives Cal Load Port Exit Menu
System Test Random Shuffle Random /No Scan Pick Each Bin Pick All Report Results Exit Menu
Robot Control Empty Load Port Pick Bin Pick Drive Place Bin Place Drive Barcode Bin Barcode Drive Exit Menu
Diagnostics Home All Selftest All Status Actuator Move Actuator Inventory Exercise All Exit Menu
Quantum|ATL 7100 Series Library Operator's Guide
25
Chapter 2 Operating the Library Using the Control Panel Menus
Figure 15 Menu Navigation Example
Status Display
Switch
Description
Main menu function "Configuration"
Menu: Configuration Menu: Configurati Inquiry SCSI Address. . SUCCESS Menu: Auto Clean Enabled<
SELECT -- Select the "Configuration" menu
Ø Ø Ø Ø
-- Bypass the "Inquiry" submenu -- Bypass the "SCSI Address" submenu -- Bypass the "Power-Up State" submenu -- Bypass the "Num of Drives" submenu
Submenu function "Auto Clean"
SELECT -- Choose the "Auto Clean" submenu
SELECT -- Select the "Enabled" Option -- The SDA displays the status "SUCCESS" when the function is finished. -- Press the or button and the SELECT button simultaneously to exit the menu mode or use them separately to navigate to the Exit or another function.
"<" (less than sign) indicates feature is active
Exiting from Menu Mode: Conventional Method
2
Use the and buttons to navigate to an Exit option, then press the SELECT button. This takes you one level up in the menu hierarchy.
1 Continue until the following is displayed in the SDA. [. . . ] Il modulo Dallas Semiconductor DS12B887 contiene una batteria al litio sulla scheda madre. Utilizzare questo tipo di batterie in accordo con le normative vigenti.
PRECAUCIÓN
0
Este producto contiene una batería de litio. El modelo Dallas Semiconductor DS12B887 de la placa base contiene una batería de litio. Deseche la batería conforme a la normativa vigente de aplicación.
VARNING!
0
Denna produkt innehåller ett litiumbatteri. [. . . ]