User manual QUANTUM 6444602 03 A01

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual QUANTUM 6444602 03 A01. We hope that this QUANTUM 6444602 03 A01 user guide will be useful to you.


QUANTUM 6444602 03 A01 : Download the complete user guide (2912 Ko)

Manual abstract: user guide QUANTUM 6444602 03 A01

Detailed instructions for use are in the User's Guide.

[. . . ] More information on the electrical requirements is provided in the Quantum PX720 Pre-Installation Site Survey Instructions. Caution: The PX720 library must be connected to a grounded electrical outlet. Selecting an Installation Location 5 Quantum PX720 Unpacking and Installation Instructions Document 6444602-03 A01 August 2004 Environmental Conditions The installation site must have the following environmental conditions: 0 · · · Humidity: 20%-80% non-condensing Temperature: 15°C-32°C (59°F-90°F) Altitude: sea level to 3048 meters (10, 000 feet) These environmental conditions apply when the library is in operation. Note: For additional library specifications (including environmental requirements during shipping and storage), see appendix A in the Quantum PX720 Series User's Guide. Preparing for the Installation 0 Before you begin the installation procedure in this section, make the following preparations as described in these sections: · · Providing necessary tools and equipment for installation Taking ESD precautions Providing Necessary Tools and Equipment 0 Provide the following tools for unpacking the library: · · · · · · · · #2 PHILLIPS® screwdriver Snips for metal bands Safety goggles 3/8 open-ended wrench or socket 3/4 inch open-end wrench (included in accessory kit) 3/16 in. Allen® wrench 7/16 inch wrench or socket Carpenter's level Provide the following tools for leveling the library: Taking ESD Precautions 0 Some components within the PX720 library contain static-sensitive parts. [. . . ] 9 Remove the accessory kit from the pallet and place it at a location to be accessed later. hex head bolts, lock washers, and flat washers removed in step 7 to secure the ramp to the pallet (see figure 10). Figure 10 Lowering the Ramp Ramp Hex head bolts Positioning the Library0 To position the library: 1 Map out a route to the installation site (see the Quantum PX720 PreInstallation Site Survey Instructions). 2 Remove the four restraining bolts securing the PX720 to the shipping pallet (see figure 11) using a 3/4 in open-end wrench. Unpacking the Library 11 Quantum PX720 Unpacking and Installation Instructions Document 6444602-03 A01 August 2004 Figure 11 Removing the Restraining Bolts Bolts Bolts 3 Raise the leveling feet (see figure 12). Figure 12 Raising the Leveling Feet Leveling feet in raised position 4 Inspect the library for any damage that may have occurred during shipment. 12 Unpacking the Library Quantum PX720 Unpacking and Installation Instructions Document 6444602-03 A01 August 2004 5 Carefully roll the library down the ramp (see figure 13). Warning: The Quantum PX720 with 20 tape drives weighs 1350 pounds (612 kg). Two people are required to move and install the library. Figure 13 Rolling the Library Down the Ramp 6 Guide the library to its final installation site. 8 Store the five spare screws in the robot shipping restraint as shown in figure 19. 9 Using the remaining two screws, secure the shipping restraints in the library as shown in figure 19. 18 Unpacking the Library Quantum PX720 Unpacking and Installation Instructions Document 6444602-03 A01 August 2004 Figure 19 Storing the Shipping Restraints Shipping restraints in storage position Spare screws Shipping restraints 10 From the back of the library, remove the two nuts securing the counter weight shipping restraint to the back wall with a 7/16 inch wrench (see figure 20). Figure 20 Removing the Counter Weight Shipping Restraint Shipping restraint Nuts 11 Reverse the counter weight shipping restraint and reinstall on the back wall of the library using the two nuts previously removed in step 10 (see figure 21). Unpacking the Library 19 Quantum PX720 Unpacking and Installation Instructions Document 6444602-03 A01 August 2004 Figure 21 Storing the Counter Weight Shipping Restraint Shipping restraint Nuts 12 Remove the six panel shipping restraints (three on each side) with a 7/16 in. Note: To access the lower panel restraints, you must manually trip the load port latching mechanism to release the load port. The load port latching mechanism is located between the load port and the outer skin of the panel (see below). Using the tip of a screw driver, lift the latch up to release the load port. Latch Screwdriver 20 Unpacking the Library Quantum PX720 Unpacking and Installation Instructions Document 6444602-03 A01 August 2004 Figure 22 Removing the Panel Shipping Restraints Upper shipping restraint Upper shipping restraint Load port latching mechanism Middle shipping restraint Lower shipping restraint Middle shipping restraint Lower shipping restraint Panels shown outside of library for clarity 13 Store the panel shipping restraint hardware (three sets on each side) on the lower cabinet frame as shown in figure 23. Unpacking the Library 21 Quantum PX720 Unpacking and Installation Instructions Document 6444602-03 A01 August 2004 Figure 23 Panel Shipping Restraints Storage Locations Panel restraint storage locations Left storage position shown Storing the Shipping Materials 0 To store the shipping and packaging materials for future use: 1 Detach the ramp and place on top of the pallet. 3 Place the shipping bag, foam cap, screws, internal library frame restraint, and other packaging materials on the pallet. 5 Place the cardboard box on top of the packaging materials on the pallet. 6 Secure the pallet, packaging materials, and cardboard box for future use. Leveling the Library 0 To level the library: 1 Rotate each foot of the library until it makes contact with the floor. 2 Rotate each foot an additional 1/4 turn with the open-end wrench to begin raising the library. 3 Center a carpenter's level on the top front edge of the library. Adjust the leveling foot on the low side of the library by rotating the leveling foot with the open-end wrench. 22 Unpacking the Library Quantum PX720 Unpacking and Installation Instructions Document 6444602-03 A01 August 2004 5 Repeat step 4 until the front is level. 6 Repeat step 3 and step 4 for the left edge, back edge, and right edge of the library. 8 If necessary, repeat step 3 and step 4 until all four top edges of the library are level. The unpacking is complete. Installing the Quantum PX720 Library Installing the Quantum PX720 library consists of the following steps: · Cabling the Quantum PX720 · · · · · Connecting the Cluster Controller Ethernet Cables Cabling a SCSI PX720 Library Cabling a Fibre Channel PX720 Library 0 Loading the Tape Cartridges Initial Configuration Cabling the Quantum PX720 0 After the Quantum PX720 is in its final location, the tape drives and robotics controller must be connected to the backup host system(s). Refer to the appropriate section for your PX720 installation: · · · Connecting the Cluster Controller Ethernet Cables Cabling a SCSI PX720 Library Cabling a Fibre Channel PX720 Library Connecting the Cluster Controller Ethernet Cables To connect the Cluster Controller Ethernet cables: 1 Open the back door of the Quantum PX720 to gain access to the tape drive cluster controllers (see figure 25 on page 26). 2 Refer to table 1 and figure 24 for the tape drive cluster Ethernet connections. 0 Installing the Quantum PX720 Library 23 Quantum PX720 Unpacking and Installation Instructions Document 6444602-03 A01 August 2004 Table 1 Cluster Controller Ethernet Connections Tape Drive Cluster Tape Drive Cluster 0 Cluster Controller Ethernet Connections Eth1 - to internal network from the cabinet controller Eth2 - not used Eth3 - to first FC470 if present Eth4 - to tape drive cluster 1; Eth1 Tape Drive Cluster 1 Eth1 - to tape drive cluster 0; Eth4 Eth2 - not used Eth3 - to second FC470 if present Eth4 - to tape drive cluster 2; Eth1 Tape Drive Cluster 2 Eth1 - to tape drive cluster 1; Eth 4 Eth2 - not used Eth3 - to third FC470 if present Eth4 - to tape drive cluster 3; Eth1 Tape Drive Cluster 3 Eth1 - to tape drive cluster 2; Eth4 Eth2 - not used Eth3 - to fourth FC470 if present Eth4 - to tape drive cluster 4; Eth1 Tape Drive Cluster 4 Eth1 - to tape drive cluster 3; Eth4 Eth2 - not used Eth3 - to fifth FC470 if present Eth4 - not used 24 Installing the Quantum PX720 Library Quantum PX720 Unpacking and Installation Instructions Document 6444602-03 A01 August 2004 Figure 24 Cluster Controller Ethernet Connections Cluster controller Tape drive cluster 0 I2 C Eth 1 Eth 2 Eth 3 Tape drive cluster 1 Eth 4 Tape drive cluster 2 Tape drive cluster 3 Tape drive cluster 4 Installing the Quantum PX720 Library 25 Quantum PX720 Unpacking and Installation Instructions Document 6444602-03 A01 August 2004 Cabling a SCSI PX720 Library To cable a SCSI Quantum PX720: 1 Open the back door of the Quantum PX720 to gain access to the tape drives and robotics controller (see figure 25). 0 Figure 25 Tape Drives and Robotics Controller Tape drive numbering Drive B (1) Drive D (3) Drive A (0) Drive C (2) Cluster 0, tape drives 0 through 3 Cluster 1, tape drives 4 through 7 Cluster 2, tape drives 8 through 11 Cluster 3, tape drives 12 through 15 Cluster 4, tape drives 16 through 19 SCSI HBA 2 Route a SCSI cable up through the base of the library on the right-hand side and connect the host computer to the robotics controller (see figure 25). Note: It is also possible to connect the SCSI robotics controller along with the first drive in cluster 0. 26 Installing the Quantum PX720 Library Quantum PX720 Unpacking and Installation Instructions Document 6444602-03 A01 August 2004 3 Connect the host computers to the tape drives by routing SCSI cables up through the base of the library and along the right-hand side of the cabinet (see figure 26). [. . . ] If your library is not connected to a network which uses a DHCP server to assign IP addresses, disable this function. · 36 Installing the Quantum PX720 Library Quantum PX720 Unpacking and Installation Instructions Document 6444602-03 A01 August 2004 · To change the password, use the up and down arrows to select Change Password and press Select. To change the password, enter a 6-digit password using the numbers provided on the OCP. To enable autoclean, use the up and down arrows to select Autoclean and press Select. To enable the left load port, use the up and down arrows to select Left Load Port (16) and press Select. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE QUANTUM 6444602 03 A01




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual QUANTUM 6444602 03 A01 will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.