User manual QUANTUM 6434003V4R0

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual QUANTUM 6434003V4R0. We hope that this QUANTUM 6434003V4R0 user guide will be useful to you.


QUANTUM 6434003V4R0 : Download the complete user guide (6236 Ko)

Manual abstract: user guide QUANTUM 6434003V4R0

Detailed instructions for use are in the User's Guide.

[. . . ] Quantum P4000 and P7000 Libraries User's Guide 6434003-04 Ver. 0 Quantum P4000 and P7000 Libraries User's Guide, 6434003-04, Ver. Quantum Corporation provides this publication "as is" without warranty of any kind, either express or implied, including but not limited to the implied warranties of merchantability or fitness for a particular purpose. Quantum Corporation may revise this publication from time to time without notice. [. . . ] SCSI ID assignments are not required for Ethernet based libraries. Note: Configuring Library Options The Configure Options command allows you to set the following: · · · · Power-On State--determines whether the library is on-line or in standby mode when powered up. AutoClean--allows the library to perform drive cleaning tasks automatically as needed. Retries--causes the library to automatically retry a failed command before issuing an error message. The default setting is Enabled. 3 Bar Code Labels--turns bar code scanning on or off during inventory. It should be disabled when the library contains cartridges that are not labeled. Auto Inventory--causes the library to perform an inventory whenever the library is powered up. Auto Load--causes the library to automatically move cartridges in the load port to empty storage bins as soon as the load port door closes. Detection--enables or disables the over-temperature detection warning and shutdown features of the library. Power-On Security--determines the library security level when powered up. The default setting is User. · · · · 66 Quantum P4000 and P7000 Libraries User's Guide Chapter 3 Operator Commands Configuring Library Options · P3000 Identity Mode--causes the library to return the same inquiry string as the P3000 library. Configuring a Library Option To configure a library option: 3 1 In the Operator screen, press the Configure Options button. 3 Using the arrow buttons, scroll through available values for the selected option. 4 When the New Value box displays the desired value, press the Execute button to apply the new value. 6 When you have finished making changes to library options, press the Back button until you return to the initial Operator screen. Figure 38 Configure: Options Screen About System Off-line Standby Load Port Back Forward Home Overview Configure: Options Power-On Auto Clean Auto Inventory Temp. Detection Power-On Security Tapes Operator Current Value: Retries Barcode Labels New Value: Online O Stop Auto Load P3000 Identity Execute Quantum P4000 and P7000 Libraries User's Guide 67 Chapter 3 Operator Commands Performing an Inventory Performing an Inventory 3 The Inventory Tapes command reads the bar code labels of the cartridges in the tape drives, fixed storage bins, and the load port bins. All elements that contain cartridges without labels are marked as full with no label. 2 Press the Abort button to stop continuous running of the inventory process, otherwise, the process continues until all storage elements have been inventoried. In this case, the GUI displays an error message. Moving Cartridges 3 The Move Cartridges command allows you to move any tape cartridge in the library to the destination you specify. This destination can be a storage bin, a tape drive, the load port, or the gripper. Note: To move a cartridge from a tape drive, issue an Unload Drive command as explained in Unloading a Drive. To move a cartridge: 1 In the Operator screen, press the Move Cartridges button. The GUI displays the Control: Move Cartridges screen, with the Source input field active (see figure 39). 68 Quantum P4000 and P7000 Libraries User's Guide Chapter 3 Operator Commands Moving Cartridges Figure 39 Control: Move Cartridges Screen Backspace button: Use this button to erase a partial entry - character by character About System Off-line Standby Load Port Back Forward Home Overview Tapes Operator 1 3 5 7 9 2 4 6 8 0 Control: Move Cartridge _ Storage Bin Drive Load Port Gripper Execute PTM Source: Destination: Range: O Stop Select 2 Identify the source element of the cartridge to be moved. Proceed as follows: a Press the appropriate source element button (Storage Bin, Tape Drive, Load Port, or Gripper). When you press an element type, the Range field (below the Destination field) displays the range of addresses. [. . . ] Mixed media gripper MSBF MTBF MTTR A specialized gripper assembly which will accept DLT, SDLT, or LTO tape cartridges. Mean Swaps Before Failure Mean Time Between Failures Mean Time To Repair Multi-unit Refers to linking up to five P4000 and/or P7000 tape libraries together using Quantum's Pass Through Mechanism. National Electrical Manufacturers Association N NEMA Network interface Card (NIC) A NIC is a device that handles communication between a device and other devices on a network. NVRAM Non-Volatile Random Access Memory is a type of memory that retains its contents when power is turned off. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE QUANTUM 6434003V4R0




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual QUANTUM 6434003V4R0 will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.