User manual POWERDSINE 6548

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual POWERDSINE 6548. We hope that this POWERDSINE 6548 user guide will be useful to you.


POWERDSINE 6548 : Download the complete user guide (507 Ko)

Manual abstract: user guide POWERDSINE 6548

Detailed instructions for use are in the User's Guide.

[. . . ] Power over Ethernet Midspans PD-6548 48-Port Model IEEE 802. 3af-compliant User Guide PD-6548 Power over Ethernet Solutions 2 Cat. No. : 06-6860-056 PD-6548 Notice The information contained herein is believed to be accurate and reliable at the time of printing. However, due to ongoing product improvements and revisions, PowerDsineTM cannot accept responsibility for inadvertent errors, inaccuracies, subsequent changes or omissions of printed material. reserves the right to make changes to products and to their specifications as described in this document, at any time, without prior notice. [. . . ] rate, indicating an out-of-power budget, thus, this port will not deliver power. The power distribution method is based on "First Come, First Served" logic. Sometimes, connected operating PDs significantly increase or suddenly raise their power requirements. If the required power exceeds the available power, the Power over Ethernet Midspan starts to turn off ports in accordance with their priority (the first turned off port is the lower priority port) until the total power is once again under the maximum limit. Default priority is establishid by port number: the higher the port number is, the lower priority it gets. No. : 06-6860-056 PD-6548 2. 2 2. 2. 1 10/100BASE-TX Ports Definition Data Input Ports The Midspan has 48 10/100Base-TX data input ports, configured in a noncrossover manner (straight-wired). No. : 06-6860-056 PD-6548 Table 2-1: Power Status Indications Indicator Color Off AC Symptom Internal power supply unit is unplugged or faulty Remarks Internal power supply voltage is too low. Green Orange Indicates AC power Internal power supply voltage input active is within tolerance. Internal problem alarm Built in Test (BIT) failed. Table 2-2: Port Status Indications Port LED Color Off Port Load Conditions Non-active load or unplugged port. Power to the port is not connected or, if previously connected ­disconnected at the moment. No DC voltage is present on the spare pairs. Green Green blinks at a 1 sec. Total aggregated power exceeds pre-defined power budget (400w by default). Power over Ethernet Solutions 13 Cat. No. : 06-6860-056 PD-6548 2. 4 Connectors The Midspan's front panel includes a Console port (RJ-45 connector) that supports two communication types: 1. Standard DTE Ethernet connector only at the web managable version of the midspan. This connector is a standard 10/100BaseTX port that is used for remote management of the device (see Table 2-3). For connecting the port to a switch output, use a straight-through ethernet cable. for connecting the port directly to a PC port, use a crossed-over ethernet cable. Table 2-3: Console Ethernet Connector Pin # 1 2 3 4 5 6 7 8 Label TX+ TXRX+ spare spare RXspare spare Description Plus signal, transmit from midspan Minus signal, transmit from midspan Plus signal, received to midspan Minus signal, received to midspan 2. Proprietary RS232 connector for console purposes: The user may connect a terminal and perform software loading via the connector, using the console cable included in the supplied kit. The console port is set to 38, 400-baud, 8 data bits, no parity and 1 stop bit. The RJ-45 connector of the cable should be connected to the Midspan's console terminal and the D-type 9 pin should be connected to the PC. Pin connections for the D-type connector are as follows: Power over Ethernet Solutions 14 Cat. No. : 06-6860-056 PD-6548 Table 2-4: Console Cable D-type Connector Pin # 1 2 3 4 5 6 7 8 Label spare RD TD spare GND spare spare spare DTE receive data DTE transmit data DTE GND Description Each input port is configured as shown in Figure 2-3, as data "Pass-Through" ports for all data pins (pins 1, 2, 3 and 6). [. . . ] Remove and re-apply power to the device and check the indicators during power up sequence as described in Para. The Midspan did not detect a PD and therefore the port is not enabled. Verify that you are using a standard Category 5/5e/6, straight-wired cable, with four pairs. If an external power splitter is in use, replace it with a known-good splitter. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE POWERDSINE 6548




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual POWERDSINE 6548 will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.