User manual POULAN PRO PPB200E

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual POULAN PRO PPB200E. We hope that this POULAN PRO PPB200E user guide will be useful to you.


POULAN PRO PPB200E : Download the complete user guide (309 Ko)

You may also download the following manuals related to this product:

   POULAN PRO PPB200E (316 ko)

Manual abstract: user guide POULAN PRO PPB200E

Detailed instructions for use are in the User's Guide.

[. . . ] R ENGLISH ESPAÑOL Instruction Manual Manual de Instrucciones Manuel d'Instructions PPB200E For Occasional Use Only DANGER: Read and follow all Safety Rules and Operating Instructions before using this product. PELIGRO: Lea el manual de instrucciones y siga todas las advertencias e instrucciones de seguridad. DANGER: Lire le manuel d'instructions et bien respecter tous les avertissements et toutes les instructions de sécurité. Tout défaut de le faire pourrait entraîner des blessures graves. Poulan PRO 1030 Stevens Creek Road Augusta, GA 30907 FRANÇAIS 545137274 11/30/06 UL CLASSIFIED PRODUCT NOTICE Only the following Gasoline Powered Combination Gardening Appliance powerhead models and their respective attachments have been Classified by Underwriters Laboratories, Inc. , in accordance with the applicable safety requirements. [. . . ] Call 1-800-554-6723. FUELING ENGINE when refueling. IMPORTANT WARNING: Remove fuel cap slowly To obtain the correct oil mix ratio, pour 3. 2 ounces of 2- cycle synthetic oil into one gallon of fresh gas. Before operation, gasoline must be mixed with a good quality synthetic 2-cycle air-cooled engine oil designed to be mixed at a ratio of 40:1. A 40:1 ratio is obtained by mixing 3. 2 ounces (95 ml) of oil with 1 gallon (4 liters) of unleaded gasoline. DO NOT HELPFUL TIP Experience indicates that alcohol blended fuels (called gasohol or using ethanol or methanol) can attract moisture which leads to separation and formation of acids during storage. To avoid engine problems, empty the fuel system before storage for 30 days or longer. Drain the gas tank, start the engine and let it run until the fuel lines and carburetor are empty. Never use engine or carburetor cleaner products in the fuel tank or permanent damage may occur. See the STORAGE section for additional information. HOW TO STOP YOUR UNIT 8 S To stop the engine, move the ON/OFF switch to the OFF position. STARTING A FLOODED ENGINE ON/OFF Switch HOW TO START YOUR UNIT WARNING: Avoid any contact with the muffler. A hot muffler can cause serious burns. Flooded engines can be started by placing the ON/OFF switch in the ON position. Move the start lever to the RUN position and fully squeeze throttle trigger. Pull the starter handle repeatedly while squeezing throttle trigger until engine starts and runs. This could require pulling the starter handle many times, depending on how badly the unit is flooded. If the unit still doesn't start, refer to TROUBLESHOOTING TABLE or call 1-800-554-6723. OPERATING THE COUPLER Starting Position If your engine still does not start after following these instructions, please call 1- 800- 554- 6723. - HELPFUL TIP This model is equipped with a coupler which enables optional attachments to be installed. PP5000P STARTING A COLD ENGINE NOTE: DO NOT squeeze the throttle trigger until the engine has started and runs. Starter Handle Start Lever Primer Bulb tachments, place the unit on a flat surface for stability. Upper Shaft Coupler Lower Attachment LOOSEN REMOVING TRIMMER ATTACHMENT (OR OTHER OPTIONAL ATTACHMENTS) CAUTION: When removing or installing at- WARNING: Always stop unit and disconnect spark plug before removing or installing attachments. Muffler 5. Allow unit to run for 5 seconds, then fully squeeze the throttle trigger to disengage the starting system. 2. TIGHTEN Knob Press and hold the locking/release button. Pull starter rope sharply while squeezing throttle trigger until engine runs. NOTE: Normally, the warm starting procedure can be used within 5-10 minutes after the unit is turned OFF. If the unit sits for more than 10 minutes without being ran, it will be necessary to start the unit by following the steps under STARTING A COLD ENGINE or following the starting instruction steps shown on the unit. Coupler Upper Shaft Lower Attachment 3. While securely holding the engine and upper shaft, pull the attachment straight out of the coupler. INSTALLING OPTIONAL ATTACHMENTS 1. [. . . ] Where a warrantable condition exists, Poulan PRO will repair your small off-road engine at no cost to you. MANUFACTURER'S WARRANTY COVERAGE: If any emissions related part on your engine (as listed under Emissions Control Warranty Parts List) is defective or a defect in the materials or workmanship of the engine causes the failure of such an emission related part, the part will be repaired or replaced by Poulan PRO. OWNER'S WARRANTY RESPONSIBILITIES: As the small off-road engine owner, you are responsible for the performance of the required maintenance listed in your instruction manual. Poulan PRO recommends that you retain all receipts covering maintenance on your small off-road engine, but Poulan PRO cannot deny warranty solely for the lack of receipts or for your failure to ensure the performance of all scheduled maintenance. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE POULAN PRO PPB200E




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual POULAN PRO PPB200E will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.