User manual PHOENIX GOLD OCTANE R

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual PHOENIX GOLD OCTANE R. We hope that this PHOENIX GOLD OCTANE R user guide will be useful to you.


PHOENIX GOLD OCTANE R : Download the complete user guide (1518 Ko)

Manual abstract: user guide PHOENIX GOLD OCTANE R

Detailed instructions for use are in the User's Guide.

[. . . ] · Optional LPL44TM Low Pass Level controller allows the driver to adjust bass volume from the driver's seat. · Optional RDDPTM Remote Diagnostic Display Panel allows the driver to monitor the amplifier's battery voltage, power-on, thermal and overload status with use of the SDTTM or RDDPTM kit. CROSSOVER FREQUENCY Controls the high and low pass crossover point symetrically for the high and low pass speaker outputs. The crossover is always engaged with a frequency adjustable from 40Hz to 800Hz with a 24dB per octave slope. INPUTS Connect preamp signal cables from the headunit to these terminals. To maximize noise rejection, we recommend using Phoenix Gold ZEROpoint Musical Reference, ZEROpoint Pro, ZEROpoint QLX, ZEROpoint TRX, XS560 or XS460 series twisted pair interconnects. STEREO/MONO SWITCH The low pass section of the amplifier will receive a mono signal when the button is set to the IN position and a stereo signal when set to the OUT position. [. . . ] LOW PASS POWER LED When lit the low pass section of the amplifier is on indicating it is grounded through the B- terminal and is receiving voltage through the B+ and remote turn-on terminals. LOW PASS SPEAKER OUTPUTS Used to connect the amplifier to low pass speakers. Minimum impedance is 2 ohms bridged or 1 ohm stereo. STATUS LEDS BLUE: Three SuperbriteTM blue LEDs on top of the amplifier light when the high pass section of the amplifier is turned on indicating it is grounded through the B- terminal and is receiving voltage through the B+ and remote turn-on terminals. If the internal heatsink reaches 115 degrees Celsius, the amplifier shuts down and continues to run the fan at high speed until the internal temperature falls below 115 degrees. RED: Lights if the amplifier shuts down due to excessive output current. Common reasons for excessive output current are chafed speaker cables touching the vehicle's chassis, speaker leads touching each other or a damaged speaker voice coil. 160 300 BYPASS OUTPUTS Provides a full range signal for an additional amplifier or signal processor. LPL CONTROL PORT This port is for connecting the optional LPL44 TM Remote Lowpass Level Control knob. The LPL44TM allows up to 20dB of subwoofer volume adjustment from the driver's seat of the low pass section of the amplifier. 40 800 HIGH PASS SPEAKER OUTPUTS Used to connect the high pass section of the amplifier to speakers. Minimum impedance is 2 ohms bridged or 1 ohm stereo. FREQ 160 300 L HIGH PASS SPEAKER L+ LR+ RSENS R INPUT BYPASS OUTPUT LPL MADE IN AMERICA POWER B­ B+ R 40 800 LOW PASS STEREO/MONO REMOTE CONTROL POWER LOWPASS POWER SUBSONIC FILTER LOW PASS SPEAKER L+ LR+ RBASS SENS B­ B+ R Q SELECT 6 + BRIDGED . 2 RDDP 0 + BRIDGED - 18 6 . 2 RDDP INPUT SENSITIVITY This control adjusts the amplifier's sensitivity to incoming signals. While the SDT includes a DC voltmeter and a tri-color status LED. REMOTE TURN-ON TERMINAL Connect to a switched 12 Vdc source such as the headunit's "remote" or power antenna wire. REMOTE TURN-ON TERMINAL Connect to a switched 12 Vdc source such as the headunit's "remote" or power antenna wire. Continuous Output Power at 1% THD (watts): Into 4 ohms Stereo @ 12. 5 Vdc (IASCA/USAC) . (or "Phoenix Gold") warrants its products against defects in materials and workmanship for a limited period of time. For a period of one (1) year from date of original purchase, we will repair or replace the electronic product, at our option, without charge for parts and labor. The limited warranty period is EXTENDED to three (3) years from date of original purchase if the product was originally installed by an authorized Phoenix Gold electronics dealer and accompanied by a valid sales receipt showing a charge for installation. Customer must pay all parts and labor charges after the limited warranty period expires. The limited warranty period for factory refurbished products expires after ninety (90) days from date of original purchase. This limited warranty applies only to purchases from authorized Phoenix Gold Electronics/Speaker retailers. This limited warranty is extended only to the original purchaser and is valid only to consumers in the United States. Consumers are required to provide a copy of the original sales invoice from an authorized Phoenix Gold dealer when making a claim against this limited warranty. [. . . ] This limited warranty is extended only to the original purchaser and is valid only to consumers in the United States. Consumers are required to provide a copy of the original sales invoice from an authorized Phoenix Gold dealer when making a claim against this limited warranty. This limited warranty only covers failures due to defects in materials or workmanship that occur during normal use. It does not cover failures resulting from accident, misuse, abuse, neglect, mishandling, misapplication, alteration, faulty installation, modification, service by anyone other than Phoenix Gold, or damage that is attributable to Acts of God. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE PHOENIX GOLD OCTANE R




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual PHOENIX GOLD OCTANE R will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.