User manual PEAVEY ICA 1200

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual PEAVEY ICA 1200. We hope that this PEAVEY ICA 1200 user guide will be useful to you.


PEAVEY ICA 1200 : Download the complete user guide (5575 Ko)

Manual abstract: user guide PEAVEY ICA 1200

Detailed instructions for use are in the User's Guide.

[. . . ] Intended to alert the user to the presence of uninsulated "dangerous voltage" within the product's enclosure that may be of sufficient magnitude to constitute a risk of electric shock to persons. WARNING: To prevent electrical shock or fire hazard, do not expose this appliance to rain or moisture. Before using this appliance, read the operating guide for further warnings. INTRODUCTION Congratulations on your purchase of an Architectural Acoustics ICATM (Industrial Contractor Amplifier) from Peavey Electronics. [. . . ] Due to our efforts for constant improvements, features and specifications are subject to change without notice. 73 volts @ 4 ohms, 2 volts @ 8 ohms Input Impedance: 20 k ohms, balanced Hum and Noise: >-115 dB, "A" weighted referenced to rated power @ 8 ohms Crosstalk: >-55 dB, "A" weighted referenced to rated power @ 8 ohms Current Draw @ 1/8 power: 575 watts @ 4 ohms, 380 watts @ 8 ohms Current Draw @ 1/3 power: 1185 watts @ 4 ohms, 860 watts @ 8 ohms Idle Current Draw: 35 VA in Standby Mode Maximum Current Draw: 2, 760 VA (time limited by breaker) Thermal Emissions (BTU/hr. ): 940 @ 1/8 power 4 ohms, 615 @ 1/8 power 8 ohms, 1830 @ 1/3 power 4 ohms, 1335 @ 1/3 power @ 8 ohms Cooling: 120 mm DC fan, off until heatsinks reach 45° C, then variable speed Controls: 2 rear panel attenuators, sequential turn-on / off Indicator LEDs: 2 Clip, 2 Signal, 2 LFC, 1 Protect, 1 Power Protection: Temp. , DC, turn-on bursts, subsonic, incorrect load or short Connectors: 8-pin plugable signal input, 4-pin plugable sequential power, 4-terminal barrier strip, IEC AC power connector Construction: All steel; 16 ga. Due to our efforts for constant improvements, features and specifications are subject to change without notice. 1% @ 200 W from 20 Hz - 20 kHz with both channels driven ICA 400V-100: <0. 15% @ 200 W from 20 Hz 20 kHz with both channels driven THD (one channel driven): ICA 400V-70: <0. 5 volts for rated output Input Impedance: 20 k ohms, balanced Hum and Noise: > -110 dB, "A" weighted referenced to rated power Crosstalk: ICA 400V-70: >-70 dB, "A" weighted referenced to rated power ICA 400V-100: >-65 dB, "A" weighted referenced to rated power Current Draw @ 1/8 power: ICA 400V-70: 415 watts ICA 400V-100: 385 watts Current Draw @ 1/3 power: ICA 400V-70: 600 watts ICA 400V-100: 565 watts Idle Current Draw: ICA 400V-70: 38 watts in Standby Mode ICA 400V-100: 43 watts in Standby Mode Maximum Current Draw: ICA 400V-70: 970 watts for rated power ICA 400V-100: 840 watts for rated power Thermal Emissions (BTU/hr. ): 500 @ 1/3 power, 350 @ 1/8 power Cooling: 80 mm DC fan, off until heatsinks reach 45o C, then variable speed Controls: 2 rear panel attenuators, sequential turn-on / off Indicator LEDs: 2 Clip, 2 Signal, 2 LFC, 1 Protect, 1 Power Protection: Temp. , DC, turn-on bursts, subsonic, incorrect load or short Connectors: 8-pin plugable signal input, 4-pin plugable sequential power, 4-terminal barrier strip, IEC AC power connector Construction: All steel; 16 ga. Due to our efforts for constant improvements, features and specifications are subject to change without notice. 3 dB at 1 watt Power Bandwidth: ICA 800V-70: 10 Hz - 100 kHz; +0, -3 dB at rated power ICA 800V-100: 10 Hz - 50 kHz; +0, -3 dB at rated power THD (two channels driven): ICA 800V-70: <0. 15% @ 400 W from 20 Hz 20 kHz with both channels driven ICA 800V-100: <0. 1% @ 400 W from 20 Hz - 20 kHz with both channels driven THD (one channel driven): <0. 5 volts for rated output Input Impedance: 20 k ohms, balanced Hum and Noise: > -108 dB, "A" weighted referenced to rated power Crosstalk: > -65 dB, "A" weighted referenced to rated power Current Draw @ 1/8 power: ICA 800V-70: 765 watts ICA 800V-100: 775 watts Current Draw @ 1/3 power: ICA 800V-70: 1, 100 watts ICA 800V-100: 1, 150 watts Idle Current Draw: 45 watts in Standby Mode Maximum Current Draw: ICA 800V-70: 1, 680 watts for rated power ICA 800V-100: 1, 700 watts for rated power Thermal Emissions (BTU/hr. ): 550 @ 1/8 power, 835 @ 1/3 power Cooling: 120 mm DC fan, off until heatsinks reach 45o C, then variable speed Controls: 2 rear panel attenuators, sequential turn-on / off Indicator LEDs: 2 Clip, 2 Signal, 2 LFC, 1 Protect, 1 Power Protection: Temp. , DC, turn-on bursts, subsonic, incorrect load or short Connectors: 8-pin plugable signal input, 4-pin plugable sequential power, 4-terminal barrier strip, IEC AC power connector Construction: All steel; 16 ga. Due to our efforts for constant improvements, features and specifications are subject to change without notice. 73 volts @ 4 ohms, 2 volts @ 8 ohms Input Impedance: 20 k ohms, balanced Hum and Noise: >-115 dB, "A" weighted referenced to rated power @ 8 ohms Crosstalk: >-55 dB, "A" weighted referenced to rated power @ 8 ohms Current Draw @ 1/8 power: 575 watts @ 4 ohms, 380 watts @ 8 ohms Current Draw @ 1/3 power: 1185 watts @ 4 ohms, 860 watts @ 8 ohms Idle Current Draw: 35 VA in Standby Mode Maximum Current Draw: 2, 760 VA (time limited by breaker) Thermal Emissions (BTU/hr. ): 940 @ 1/8 power 4 ohms, 615 @ 1/8 power 8 ohms, 1830 @ 1/3 power 4 ohms, 1335 @ 1/3 power @ 8 ohms Cooling: 120 mm DC fan, off until heatsinks reach 45° C, then variable speed Controls: 2 rear panel attenuators, sequential turn-on / off Indicator LEDs: 2 Clip, 2 Signal, 2 LFC, 1 Protect, 1 Power Protection: Temp. , DC, turn-on bursts, subsonic, incorrect load or short Connectors: 8-pin plugable signal input, 4-pin plugable sequential power, 4-terminal barrier strip, IEC AC power connector Construction: All steel; 16 ga. Due to our efforts for constant improvements, features and specifications are subject to change without notice. [. . . ] Include a detailed description of the problem, together with a copy of your sales receipt or other proof of date of purchase as evidence of warranty coverage. Some states do not allow limitations on how long an implied warranty lasts, so the above limitation may not apply to you. Some states do not allow the exclusion or limitation of incidental or consequential damages, so the above limitation or exclusion may not apply to you. This Warranty gives you specific legal rights, and you may also have other rights which vary from state to state. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE PEAVEY ICA 1200




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual PEAVEY ICA 1200 will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.