User manual PEAVEY DYNAMIC SYSTEM CONTROLLER HDH

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual PEAVEY DYNAMIC SYSTEM CONTROLLER HDH. We hope that this PEAVEY DYNAMIC SYSTEM CONTROLLER HDH user guide will be useful to you.


PEAVEY DYNAMIC SYSTEM CONTROLLER HDH : Download the complete user guide (1240 Ko)

Manual abstract: user guide PEAVEY DYNAMIC SYSTEM CONTROLLER HDH

Detailed instructions for use are in the User's Guide.

[. . . ] Unplug this apparatus during lightning storms or when unused for long periods of time. Servicing is required when the apparatus has been damaged in any way, such as power-supply cord or plug is damaged, liquid has been spilled or objects have fallen into the apparatus, the apparatus has been exposed to rain or moisture, does not operate normally, or has been dropped. " Connect only to a power supply of the type marked on the unit adjacent to the power supply cord. If this product is to be mounted in an equipment rack, rear support should be provided. [. . . ] To ensure against potentially dangerous exposure to high sound pressure levels, it is recommended that all persons exposed to equipment capable of producing high sound pressure levels such as this amplification system be protected by hearing protectors while this unit is in operation. Lors de l'utilsation sur pied ou pole de support, assurez dans le cas de déplacement de l'ensemble enceinte/ support de prévenir tout basculement intempestif de celui-ci. Ruggedly constructed, DYNAMIC SYSTEM CONTROLLER HDH gives the operator the flexibility to establish a two-way stereo system or run in a three-way mono configuration. The DYNAMIC SYSTEM CONTROLLER HDH has variablestate filter controls with 24 dB per octave filters and utilizes XLR inputs and outputs for balanced operation from 20 Hz to 20 kHz. This 2-position rocker switch applies mains power to the unit when in the ON position. This switch selects between stereo 2-way operation and mono 3-way operation. This control is used to optimize the channel 1 gain between the mixer and the power amps for channel 1. Controls output level of channel 1 low frequency signal (signal below the selected crossover point) present at channel 1 low output XLR. Controls output level of channel 1 high frequency signal (signal above the selected crossover point) present at channel 1 high output XLR. This switch multiplies the value indicated on the Crossover Selector Control times 10. When engaged, the range will change from 100 Hz to 1 kHz through 1 kHz to 10 kHz. When engaged, the range will change from 100 Hz to 1 kHz through 1 kHz to 10 kHz. This controls the output level of mid signals (those below the selected crossover point) present at mid output XLR. This controls the output level of the highs (signals above the selected crossover point) present at high output XLR. This allows users to choose their desired crossover point for mids and highs. This switch multiplies the value indicated on the Crossover Selector Control times 10. When engaged, the range will change from 100 Hz to 1 kHz through 1 kHz to 10 kHz. an AC mains cord having the appropriate AC plug and ratings for the intended operating voltage is included in the carton. If the outlet used does not have a ground pin, a suitable grounding adapter should be used and the third wire should be grounded properly. To prevent the risk of shock or fire hazard, always make sure that the equalizer and all associated equipment is properly grounded. If for any reason you are unable to power up this unit, remove the fuse by pulling out the holder. If the fuse continues to fail contact your nearest Certified Peavey Service Center. [. . . ] Low Frequency Output: -86 dBu below 80 dB High Frequency Output: -84 dBu below -78 dB Maximum Input Level: +14 dBu, (channel gain @ 0 dB input level controls set at 0 dB) +22 dBu Maximum Output Level: +22 dBu, unbalanced +28 dBu, balanced Input Impedance: 10 k ohms unbalanced CONNECTORS Inputs: XLR Balanced Outputs: XLR Balanced Power Requirements: 120V AC, 50/60 Hz, 20 watts (domestic model) This XLR female 3-pin connector provides a balanced input for channel 1. What This Warranty Does Not Cover The Warranty does not cover: (1) damage caused by accident, misuse, abuse, improper installation or operation, rental, product modification or neglect; (2) damage occurring during shipment; (3) damage caused by repair or service performed by persons not authorized by Peavey; (4) products on which the serial number has been altered, defaced or removed; (5) products not purchased from an Authorized Peavey Dealer. Who This Warranty Protects This Warranty protects only the original retail purchaser of the product. 2 years *(+ 3 years) 2 years *(+ 1 year) 3 years *(+ 2 years) 1 year *(+ 1 year) 2 years 1 year 90 days [*Denotes additional warranty period applicable if optional Warranty Registration Card is completed and returned to Peavey by original retail purchaser within 90 days of purchase. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE PEAVEY DYNAMIC SYSTEM CONTROLLER HDH




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual PEAVEY DYNAMIC SYSTEM CONTROLLER HDH will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.