User manual PARKSIDE PDT 40 B2

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual PARKSIDE PDT 40 B2. We hope that this PARKSIDE PDT 40 B2 user guide will be useful to you.


PARKSIDE PDT 40 B2 : Download the complete user guide (2447 Ko)

You may also download the following manuals related to this product:

   PARKSIDE PDT 40 B2 (2806 ko)
   PARKSIDE PDT 40 B2 (2805 ko)
   PARKSIDE PDT 40 B2 (2805 ko)
   PARKSIDE PDT 40 B2 (3030 ko)
   PARKSIDE PDT 40 B2 (3030 ko)
   PARKSIDE PDT 40 B2 (2806 ko)
   PARKSIDE PDT 40 B2 (2806 ko)
   PARKSIDE PDT 40 B2 (2862 ko)
   PARKSIDE PDT 40 B2 (3030 ko)
   PARKSIDE PDT 40 B2 (2862 ko)
   PARKSIDE PDT 40 B2 (2862 ko)
   PARKSIDE PDT 40 B2 (2806 ko)
   PARKSIDE PDT 40 B2 (3030 ko)
   PARKSIDE PDT 40 B2 (2805 ko)
   PARKSIDE PDT 40 B2 (2620 ko)

Manual abstract: user guide PARKSIDE PDT 40 B2

Detailed instructions for use are in the User's Guide.

[. . . ] We will not accept liability for loss or damage arising from improper use. 513 kg Trigger type: Compressed air Maximum permissible pressure: 8 bar Introduction / Safety of the fastener driving tool Recommended pressure range: 4 to 7. 7 mm Recommended Hose diameter: ∅ 9 mm Compressed air quality:  Cleaned, oil-misted and condensate-free Noise and vibration data: Measured values for noise are determined in accordance with EN 12549:1999, EN ISO 4871. These values are characteristic values referenced to the device and do not reflect noise development at the work location. [. . . ]  uring work, hold the fastener driving D tool so that head and body can not be injured by possible kickback due to a fault in the power supply or from hard places in the workpiece. Following this instruction will prevent danger due to uncontrolled flying fasteners and overloading the device.  Before transporting, disconnect the fastener driving tool from the compressed air network, particularly when using ladders or are moving with an unaccustomed body posture.  t the workplace, only carry the fasA tener driving tool by its grip and never with the trigger actuated. Pay Fasteners may strike completely through thin workpieces or slide off corners or edges to cause a danger to persons. Wearing personal protective devices such as dust mask, non-slip safety shoes, safety helmet or hearing protectors, depending on the type of fastener driving tool and its application, reduces the risk of injuries. 24 GB Safety of the fastener driving tool / Preparing the product for use / Operation  loosening the hose coupling, hold the When hose firmly in your hand to prevent injuries caused by a rebounding hose.  e absolutely certain to use a ¼‘„ threaded B nipple and a quick-release coupling for the compressed air connection.  place your hands near the mouth when Never the device is ready to operate. If the device exhibits defects, it must not be operated under any circumstances. Never Do insert pointed and / or metal objects into the inside of the device.  do so, press the compressed air hose quickTo release coupling (not included in the scope of delivery) on the ¼“ threaded nipple 4 of the compressed air tacker.  Connect the other end of the compressed air hose to the (filter) pressure reducer on the compressor.  Press the magazine lever 12 and pull the magazine cover back to its stop position. 01 accessories / tools  se only the accessories and attachments U detailed in the operating instructions. The use of fasteners or other accessories other than those recommended in the operating instructions could lead to you suffering an injury. reparing P 5 02 the product for use NOTE: always wear the protective goggles supplied before putting the tool into operation. Remove the protective film from the protective goggles before using for the first time.  peration O NOTE: The compressed air tacker must only be operated with cleaned, oil-misted compressed air and must not exceed the maximum operating pressure of 8 bar. The compressor must be fitted with a pressure reducer in order to regulate the operating pressure. [. . . ] To do so, insert the nipple of the oil mister into the quick-release coupling of the (filter) pressure reducer.  connect the compressed air device to the Then quick-release coupling provided for it.  Have your fastener driving tool repaired only by qualified specialist personnel using original manufacturer parts only.  arranty W The warranty for this appliance is for 3 years from the date of purchase. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE PARKSIDE PDT 40 B2




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual PARKSIDE PDT 40 B2 will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.