User manual PARADOX DGP-NE96 SYSTEMES

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual PARADOX DGP-NE96 SYSTEMES. We hope that this PARADOX DGP-NE96 SYSTEMES user guide will be useful to you.


PARADOX DGP-NE96 SYSTEMES : Download the complete user guide (635 Ko)

Manual abstract: user guide PARADOX DGP-NE96 SYSTEMES

Detailed instructions for use are in the User's Guide.

[. . . ] LCD Keypad DGP2-641BL / DGP2-641RB System Manager's Manual for DGP-NE96 Systems Also includes Operating Instructions Table of Contents Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 Legend. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 Standard Fire Zone. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Delayed Fire Zone . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . [. . . ] Enter the number corresponding to the zone to be chimed, or use the [ ] and [ ] buttons to scroll the list of zones. Press the [ACC] button to chime or unchime the zone that appears on the screen. OR Press the [2] button to set the time period a chimed zone will beep. Enter the time that the chimed zone(s) will start LCD Keypad 14 beeping when opened (HH:MM). Enter the time that the chimed zone(s) will stop beeping when opened (HH:MM). Press [CLEAR] to exit chime programming. 8. 5 Panic Alarms Your system can be programmed to send an alarm to your monitoring station to request help from the police, a medical facility, the fire department, or anyone you wish when you press a predetermined combination of buttons. To generate a panic alarm, simultaneously press and hold the button combinations displayed in Table 3 on page 15. Your installer can program the alarm to be either silent or audible. Table 3: Panic Buttons Panic Alarm Types Emergency Panic Auxiliary Panic Fire Panic Buttons to be pressed and held simultaneously Press & hold the [1] and [3] buttons Press & hold the [4] and [6] buttons Press & hold the [7] and [9] buttons 8. 6 Quick Function Buttons You will only need to use the Quick Function Buttons upon your installer's or monitoring station's request. Only the System Master Code or user access codes with the Master feature enabled will be able to access these functions. Press the: [STAY] button to send a test report to the monitoring station. [DISARM] button to cancel communication with the WinLoad software. 9. 0 Testing and Maintenance 9. 1 Burglar Alarm Testing Two people are needed to complete this test. One person will watch the LCD screen on the keypad while the other person walks around the protected areas and opens the zones (i. e. opens the doors and windows that are protected, walk in the path of the motion detectors, etc. ). The LCD screen will display the opened zones, but if a zone does not register, contact your installer. 9. 2 Fire Alarm Testing Do NOT use an open flame or burning materials to test your fire detection devices. Your installer will provide details on the best way to test your system. 9. 3 System Maintenance Under normal use your system requires no maintenance other than regular testing. We recommend that your installer change the battery every three years. 9. 4 System Test Speak to your installer before conducting a System Test since the system must be programmed to respond to the test instructions. It is normally recommended that you conduct the system test once a week, but contact your installer for instructions concerning your particular system. Call your monitoring station to advise them that you are testing your system. Press the [8] button. 15 User's Manual The system will test all its connections and can send a report to your monitoring station. If the system detects a problem, the Trouble Display will show on the LCD screen (refer to section 7. 0 on page 12). Call your installer for repairs if any troubles occur. 10. 0 Fire and Burglar Alarms 10. 1 Standard Fire Zone During a fire alarm, the bell/siren emits an intermittent sound (BEEP-BEEP-BEEP) until silenced or reset. If the zone is a Standard Fire Zone, your system can immediately send an alert to your monitoring station. [. . . ] 89 Stay & Instant Arm . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10 Q Quick Function Buttons Answer Winload Sofware . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15 Call Winload Software . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15 Send Test Report . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE PARADOX DGP-NE96 SYSTEMES




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual PARADOX DGP-NE96 SYSTEMES will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.