User manual PARADOX DGP-848

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual PARADOX DGP-848. We hope that this PARADOX DGP-848 user guide will be useful to you.


PARADOX DGP-848 : Download the complete user guide (1249 Ko)

Manual abstract: user guide PARADOX DGP-848

Detailed instructions for use are in the User's Guide.

[. . . ] Digiplex 48-Zone Control Panel (DGP-848) Programming Guide Software Version 4. 13 Includes DGP-641BL/RB Programming Guide DGP-848 Default Installer Code 000000 (see section [800] on page 39) Default System Master code 123456 How Do I Enter Programming Mode? 1. Enter required [DATA]. Decimal and Hexadecimal Programming Table Certain sections may require the entry of one or more Hexadecimal values from 0 to F. For LCD keypads: [0] to [9] [STAY] [FORCE] [ARM] [ENTER] = values 0 to 9 respectively =A =B =C = Save current data and advance to next section [DISARM] [BYP] [MEM] [CLEAR] =D =E =F = Exit section without saving For Grafica keypads: [#] [0] to [9] = values 0 to 9 respectively = A to F (press the [#] key until the desired letter appears) Right Action Key (Exit) = Exit section without saving Center Action Key (Save) =Save current data and advance to next section DGP-848 -1- Programming Guide Table of Contents Serial Number List . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 Zone Programming. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5 Keyswitch Programming. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . [. . . ] A complete Grafica user manual is available on our website at paradox. com. Program User Code Options, Partition Assignment and Access Control features for users 001 to 096. Refer to the appropriate keypad User's Manual for instructions on how certain users can also program these values. To program user labels, refer to the LCD Keypad System Manager's Manual. Press and hold the [0] key Where sections [801] to [896] represent User #s 01 to 96. User Options (Bold = default setting) [1] [2] Master Feature off off Disabled on off Master - user can program user access codes only on on Full Master - user can program user access codes, options and assignments [3] Duress [4] Bypass [5] Arm only Set desired options [6] Stay & Instant [7] Force [8] off = access keypad's partitions only on = access any partition assigned to user Enter the Installer Code Enter the [SECTION] User Code Options Feature Select Programming Press the [ ] key User Partition Assignment Feature Select Programming Press the [ ] key Access Level and Schedule Assignment Enter digits *Note: all users can regular arm the system User Code Partition Assignment [1] User Code Has Access to Partition 1 [2] User Code Has Access to Partition 2 [3] User Code Has Access to Partition 3 [4] User Code Has Access to Partition 4 The default setting depends on the programming user's assigned partitions. For example, when a user (with master feature) that is assigned to partitions 1 and 2 programs a user code, partitions 1 and 2 will be the default setting for the new user. Set desired options Access Level and Schedule Assignment First brackets Access Level = enter level from 00 (default) to 15 (00 = access to all doors) Second brackets Schedule = enter level from 00 (default) to 15 (00 = access granted at all times) Access Control User Options Feature Select Programming Press the [ ] key Enter Access Card Set desired options Access Control User Options (default: all options Off) [1] Access Card is activated [2] Can disarm with Access Card [3] Access Card with Extended Unlocked Period [4] on on on on [5] off on off off [6] off off on off [7] off off off on Feature Can Regular Arm with Access Card Can Stay Arm with Access Card Can Instant Arm with Access Card Can Force Arm with Access Card [8] Can open armed Access Control Doors Press the [ENTER] or [ ] key to save and advance to next section Access Card Assignment Enter Access Card's serial number or present Card to the reader DGP-848 - 39 - Programming Guide Section # [900] Description Display Serial Number of Control Panel and All Modules Connected to the Combus: After entering section [900], the keypad will display the 8-digit serial number of the control panel: For LCD Keypads: Use the [ ] and [ ] keys to scroll through the serial number of each module on the combus. For Grafica keypads: Press the center action key (Next) to scroll through the serial number of each module on the combus. Reset System Master Code: To reset the System Master Code to 123456 and reset the options to default, put the "reset" jumper to on and enter section [950]. Module Reset: Reset a module's programmed contents to default by entering its serial number. detector, zone expander, etc. ) connected to the combus by entering the module's serial number. The green "LOCATE" LED on the module will begin to flash until the serial number is reentered or the appropriate "tamper" or "unlocate" switch on the module is pressed. Module Programming Mode: Enter the serial number of the module you wish to program. Module Broadcast: Copy the contents of all programming sections from one module to one or more modules of the same type. Enter the serial number of the source module, followed by the serial numbers of the modules you wish to program. To begin transferring data, press [ACC] on LCD keypads or the center action key (Start) on Grafica keypads. PLEASE NOTE: The Module Broadcast feature will only work when a module is broadcasting its data to a module or to modules of the same type and model number. For example, an APR-PRT1 (Printer Module) cannot broadcast to an APR3-PRT1. Likewise, a DGP module cannot broadcast to a DGP2 module. [950] [951] [952] [953] [954] [955] Remove Modules: After entering the section, the control panel will scan all modules connected to the combus. detector removed from the combus), the control panel will erase the module's serial number, removing the module from the control panel's memory. Paradox Memory Key [961] [962] [965] [966] Download from the Memory Key to control panel except sections [001] to [056]. Download from the Memory Key to control panel including sections [001] to [056]. Copy the control panel sections to the Memory Key except sections [001] to [056]. Copy the control panel sections to the Memory Key including sections [001] to [056]. Download Memory Key to Control Panel 1. [. . . ] Using a 20VA transformer with a battery charge current of 850mA may damage the system. This equipment must be installed and maintained by qualified service personnel only. For UL and C-UL warnings, refer to the Warnings section in the Digiplex Reference and Installation Manual. DGP-848 - 50 Programming Guide Warranty Paradox Security Systems Ltd. ("Seller") warrants its products to be free from defects in materials and workmanship under normal use for a period of one year. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE PARADOX DGP-848




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual PARADOX DGP-848 will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.