User manual PANASONIC WH-SDC05E3E5

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual PANASONIC WH-SDC05E3E5. We hope that this PANASONIC WH-SDC05E3E5 user guide will be useful to you.


PANASONIC WH-SDC05E3E5 : Download the complete user guide (2981 Ko)

You may also download the following manuals related to this product:

   PANASONIC WH-SDC05E3E5 (5347 ko)
   PANASONIC WH-SDC05E3E5 (1826 ko)
   PANASONIC WH-SDC05E3E5 (1826 ko)
   PANASONIC WH-SDC05E3E5 (1826 ko)
   PANASONIC WH-SDC05E3E5 (2981 ko)
   PANASONIC WH-SDC05E3E5 (2981 ko)
   PANASONIC WH-SDC05E3E5 (2981 ko)
   PANASONIC WH-SDC05E3E5 (2981 ko)
   PANASONIC WH-SDC05E3E5 (2981 ko)
   PANASONIC WH-SDC05E3E5 (2981 ko)
   PANASONIC WH-SDC05E3E5 (2981 ko)
   PANASONIC WH-SDC05E3E5 (2981 ko)
   PANASONIC WH-SDC05E3E5 (999 ko)
   PANASONIC WH-SDC05E3E5 (1826 ko)
   PANASONIC WH-SDC05E3E5 (1446 ko)
   PANASONIC WH-SDC05E3E5 (2981 ko)

Manual abstract: user guide PANASONIC WH-SDC05E3E5

Detailed instructions for use are in the User's Guide.

[. . . ] WARNING 2 NOTICE : When the outdoor temperature is out of the above temperature range, the heating capacity will drop significantly and outdoor unit might stop for protection control. The unit will restart automatically after a short time when the outdoor temperature is back in the limits. INDOOR UNIT AND OUTDOOR UNIT This appliance is not intended for use by persons (including children) with reduced physical, sensory or mental capabilities, or lack of experience and knowledge, unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety. Children should be supervised to ensure that they do not play with the appliance. [. . . ] Heating Priority (YES / NO) To choose the room heating as priority during HEAT + TANK mode. note: If select “Heating priority” is “YES” , Set 8 ~ 9 are irrelevant to HEAT + TANK mode. Cooling/Heating operation Interval Set To set timer for Cool mode or Heat mode during COOL + TANK mode or HEAT + TANK mode (0. If both “Heating priority” and “Cooling priority” are “YES”, Set 8 ~9 are skipped. Tank Heat-up Interval Set To set timer for Tank during COOL + TANK mode or HEAT + TANK mode (5minutes ~ 1hour 35minutes). booster Heater Function (YES / NO) To activate or deactivate tank booster heater function Note: If select “Booster heater function” is “NO” , Set 11 is skipped. Booster Heater Delay Timer Set To set delay timer for booster heater to ON if water tank temperature is not reached (20minutes ~ 1hour 35minutes). €¢ Do not use the system during sterilization to prevent scalding or overheat during shower. €¢ The sterilization function field settings must be configured by the authorized dealer according to local laws and regulation. Sterilization Day & Time Set To set timer for sterilization (only once a week, will operate even in standby condition). sterilization Temperature Set To set temperature for sterilization function (40°C ~ 75°C). Sterilization Continue Time To set timer to maintain heating temperature in order to complete the sterilization function (5minutes ~ 1hour). BASIC OPERATION OFF / ON TO TURN ON OR OFF THE UNIT • When unit is ON, operation LED is lit and the actual temperature for water outlet and outdoor ambient are shown on the control panel display. MODE TO SELECT OPERATION MODE HEAT COOL HEAT +TANK TANK COOL + TANK • HEAT MODE - To turn ON or OFF the panel/floor heating operation. - In this mode, the outdoor unit will provide heating capacity to the indoor unit. €¢ HEAT + TANK MODE - In this mode, the outdoor unit will provide heating capacity to the sanitary tank and indoor unit. - This operation is not used when the sanitary water tank is not installed. €¢ TANK MODE - To turn ON or OFF the sanitary tank operation. - In this mode, the outdoor unit will provide heating capacity to the sanitary tank. - In this mode, the outdoor unit will provide cooling capacity to the indoor unit. €¢ COOL + TANK MODE - In this mode, the outdoor unit will provide cooling capacity to the indoor unit. qUIET TO ENJOY QUIET ENVIRONMENT • This operation reduces outdoor unit noise. [. . . ] For proper treatment, recovery and recycling of old products, please take them to applicable collection points, in accordance with your national legislation and the Directives 2002/96/EC and 2006/66/EC. By disposing of these products correctly, you will help to save valuable resources and prevent any potential negative effects on human health and the environment which could otherwise arise from inappropriate waste handling. For more information about collection and recycling of old products, please contact your local municipality, your waste disposal service or the point of sale where you purchased the items. Penalties may be applicable for incorrect disposal of this waste, in accordance with national legislation. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE PANASONIC WH-SDC05E3E5




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual PANASONIC WH-SDC05E3E5 will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.