If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual OUTBACK POWER SYSTEMS SRC-BC4. We hope that this OUTBACK POWER SYSTEMS SRC-BC4 user guide will be useful to you.
Manual abstract: user guide OUTBACK POWER SYSTEMS SRC-BC4SCHEMA
Detailed instructions for use are in the User's Guide.
[. . . ] Battery Enclosure Cabling Kit SRC-BC4
For a 48-volt Battery Bank
CAUTION: Equipment Damage
See the SmartRE Installation Manual for detailed information on installing the battery cables, including torque requirements. Ensure the cables are placed in the correct order with other hardware. [. . . ] Hardware (nuts, bolts, and washers) for securing the cable to the battery should comply with the specifications from the battery manufacturer.
65"
6
3/8" Lug 3/8" Lug
5a
5 6
94"
5b
3/8" Lug 3/8" Lug
65" Black #1/0 AWG (x1) with 3/8" lugs on both ends 65" Red #1/0 AWG (x1) with 3/8" lugs on both ends 94" Red #1/0 AWG (x1) with one 5/16" lug* and one 3/8" lug *attaches to DC Breaker
5b
4b
5/16" Lug
7a
7
7b
3/8" Lug
12 Vdc
12 Vdc
7a
Hardware Order on the DC Breaker:
Bolt
5a
Hardware Order on the Shunt:
OFF
Flat Washer
Nut
3 2
DC Breaker
Locking Washer BAT () from CC
Lock Washer Flat Washer
BAT () with 3/8" lug
1 12 Vdc 12 Vdc
Chassis Ground Conductor should already be in place
6
BAT (+) with 5/16" lug
SHUNT
IMPORTANT: All configurations must comply with local and national electric codes. Factory wiring is not shown.
IMPORTANT: Grounding
Battery Negative () to Chassis Ground Bond is done through the GFDI.
#6 AWG THHN recommended
Existing Battery Enclosure
(Batteries shown as wired with SRE-BC1)
1 additional Ground Conductor will be needed
8
Proper cabinet grounding may still be required. Do not use in a Positive Ground installation.
Main Office 19009 62nd Avenue NE Arlington, WA USA 1. 360. 435. 6030
900-0106-01-00 Rev A © March 2010 OutBack Power Systems. All Rights Reserved.
Battery Enclosure Cabling Kit SRC-BC4
Electronics Enclosure
WARNING: Lethal Voltage
Review the system configuration to identify all possible sources of energy. Ensure ALL sources of power are disconnected before performing any installation or maintenance on this equipment. Confirm that the terminals are de-energized using a validated voltmeter (rated for a minimum 1000 Vac and 1000 Vdc) to verify the deenergized condition. Do not perform any servicing other than that specified in the installation instructions unless qualified to do so or as instructed to do so by OutBack Power Systems Technical Support personnel.
Electronics Enclosure
(Factory wiring not shown) BAT () 5a BAT (+)
To prepare the existing installation for the addition of the 2nd Battery Enclosure:
1. Do NOT remove 6 .
4a
(Factory wiring not shown) BAT () 5a
6
2. Remove
5b
and
4b
.
BAT (+)
6
7a
WARNING: Shock Hazard
Ensure the Inverter Charger Breaker is in OFF position BEFORE making connections.
3. Do NOT remove 2 or 3 .
GRID AC IN GEN AC IN INVERTER AC OUT INVERTER BYPASS AC LOAD #1 AC LOAD #2 GROUND FAULT CHARGE CONTROL DC LOAD SOLAR INPUT INVERTER CHARGER GRID AC IN GEN AC IN INVERTER AC OUT INVERTER BYPASS AC LOAD #1 AC LOAD #2 GROUND FAULT CHARGE CONTROL DC LOAD SOLAR INPUT INVERTER CHARGER
2nd Battery Enclosure
WARNING: Shock Hazard 6
Ensure the Inverter Charger Breaker is in OFF position BEFORE making connections. [. . . ] Then connect
.
4 4 7 7 6
Existing Battery Enclosure
(Batteries shown as wired with SRE-BC1)
Existing Battery Enclosure
(Batteries shown rewired to Series/Parallel using SRE-BC4)
6
900-0106-01-00 Rev A © March 2010 OutBack Power Systems. All Rights Reserved.
Main Office 19009 62nd Avenue NE Arlington, WA USA 1. 360. 435. 6030 [. . . ]