User manual OSCO HSLG

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual OSCO HSLG. We hope that this OSCO HSLG user guide will be useful to you.


OSCO HSLG : Download the complete user guide (7165 Ko)

Manual abstract: user guide OSCO HSLG

Detailed instructions for use are in the User's Guide.

[. . . ] HSLG INSTALLATION GUIDE ® OPERATOR SPECIALTY COMPANY, INC. CASNOVIA, MI 49318 · U. S. A. UL325 COMPLIANCE REQUIRES THE USE OF CONTACT EDGES OR PHOTOELECTRIC CONTROLS ON ALL AUTOMATIC OR REMOTELY-CONTROLLED GATE OPERATORS. Oct. 16 HSLG OPERATOR INSTALLATION GUIDE TABLE OF CONTENTS PRE-INSTALLATION INFORMATION Gate Operator Classifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 Safety Information and Warnings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 Pre-Installation Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 Warranty . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . [. . . ] Operators which are stand-alone or master units should be set to OFF, while only slave units should have this switch set to ON. -9- 3-05-14 HSLG OPERATOR INSTALLATION GUIDE TERMINAL CONNECTION DESCRIPTIONS TERMINALS 24VAC 24VAC N 24VDC+ 24VDC- COMM. 1&4 FUNCTION 24VAC DESCRIPTION OF FUNCTION Provides 24Volt AC power for accessories. Provides 24Volt DC power for accessories. 24VDC OPEN Opens the operator. Several accessories such as button stations, keypads, transmitters and card readers can be wired to open. The gate must be clearly visible from the location of any accessories wired to close. Performs the single-button function which will alternate between open and close or open, stop and close - depending on dip switch #3. This function will cause a reversal when the gate is traveling closed and will travel back to the fully open position. Any signal to this function will cause the gate to stop, reverse a short distance, and then stop again. At this time the auto close timer is disabled, and a renewed input will be required to start the gate again. Should the gate be restarted and the signal occur again prior to reaching a limit, the gate will stop again, and this time will sound the emergency alarm and lock out. This function works exactly like the OPEN OBSTRUCTION, except that it will only work in the closing direction. This function will keep the gate in its fully open position while the signal is present. This is typically used with a loop and loop detector to keep a large swing gate open while vehicular traffic is passing through. A 24Volt DC device such as a strobe light or alarm can be wired to these terminals. Depending on dip switch #2, these devices will either begin three seconds before the operator starts, or only while the motor is running. (See page 9 for details. ) 3&4 CLOSE 4&5 SINGLE-BUTTON 2&4 4&6 STOP REVERSE 4 & 50 OPEN OBSTRUCTION 4 & 51 CLOSE OBSTRUCTION SHADOW/HOLD 4 & 11 24VDC+ & 60 RUN/PRE-START You must follow all required safety precautions and instructions at all times. If any pages are missing or unreadable, contact OSCO at 1-800-333-1717 to request additional copies. Never connect a button station within reach of the gate or on the side of the gate operator. It should be adjusted high enough to keep the gate from falsely triggering the sensing, but no higher than necessary for the gate to operate. Do not defeat the purpose of this function! - 10 - 3-05-14 HSLG OPERATOR INSTALLATION GUIDE CURRENT SENSING ADJUSTMENTS Because gates vary in construction and may have different force requirements in the open and close directions to move, the OSCO control board has separate Multi-turn potentiometers for adjusting in both directions independently. The adjustment should be set light enough to maintain minimal force (50-75 lbs. ) should an obstruction occur, but high enough to keep the gate moving under normal conditions without interruption. Prior to adjusting the operator current sensing functions, make sure the gate moves freely in both directions. [. . . ] Check current sensing for proper adjustment when finished with inspection and maintenance. Be sure there are no control stations mounted within reach of the gate. Review safety literature with the customer and advise them to remove any such stations found. For slide and swing gate operators, you must inspect the gate for proper operation. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE OSCO HSLG




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual OSCO HSLG will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.