User manual OREGON SCIENTIFIC STARCK PSM06A
DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!
If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual OREGON SCIENTIFIC STARCK PSM06A. We hope that this OREGON SCIENTIFIC STARCK PSM06A user guide will be useful to you.
Manual abstract: user guide OREGON SCIENTIFIC STARCK PSM06A
Detailed instructions for use are in the User's Guide.
[. . . ] 13 Barometer . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13 Weather forecast . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15 Temperature & humidity . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15 Radio . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . [. . . ] When the unit is within 1500 km (932 miles) of a RF signal, the reception icon will blink during reception.
NOTE For best results, place the unit away from metal or electrical objects, and near a window with a clear view to the sky.
10
PS M06 English R19
10
7/16/03, 1:05 PM
TO DISABLE OR ENABLE AUTOSYNCHRONIZATION In Clock mode, press DOWN for 2 seconds to disable the auto-synchronization. The unit will not respond to radio signals until you reactivate the synchronization. Press SELECT to confirm.
ALARM When activated, the Melody Alarm starts quietly, then gradually becomes louder. Select the hour, minute, and alarm type ( for Melody Alarm or for Radio Alarm). Press
11
PS M06 English R19
11
7/16/03, 1:05 PM
EN
EN
UP or DOWN to change the setting. If you choose , also select the melody (1 - 7) and volume level (Lo or Hi). , use the radio control buttons If you choose to select the AM/FM band, radio station and volume level ( 18). Press SELECT again when you are finished.
TO TURN THE ALARM OFF OR ON Press RADIO to turn the radio alarm off. To turn the alarm off completely (deactivate it for the next day), press ALARM. CALENDAR SET DATE Clock auto-synchronization must be deactivated before you manually set the date. Press and hold SELECT for 2 seconds to enter the calendar setting mode.
SNOOZE Press the SNOOZE/LIGHT button on the top of the unit to temporarily disable the alarm for 8 minutes. 12
PS M06 English R19
12
7/16/03, 1:05 PM
3.
Select the year, month, date, and language. Press SELECT to confirm.
NOTE The language options are (E) English, (F) French, (D) German, (I) Italian, and (S) Spanish.
BAROMETER This product tracks barometric pressure changes over the past 24 hours to provide the weather forecast ( 15) and a trend line showing the direction of barometric change. Barometric changes are measured by the main (indoor) unit.
MOON PHASE Press SELECT until the Calendar Area flashes. Then, press UP or DOWN to change the date and view the corresponding moon phase.
13
PS M06 English R19
13
7/16/03, 1:05 PM
EN
EN
BAROMETRIC TREND The barometric trend arrow for the last 30 minutes is always displayed. Trend Description Pressure change (mb/hPa) 1 hr +1 Steady -1 6 hrs +3 Steady -3
VIEW THE LAST 24 HOURS Press SELECT 2 times until the Barometer Area flashes. SET UNIT AND ALTITUDE You can set the unit of measurement (mb/hPa or inHg) and altitude. Setting the altitude allows the product to take more accurate barometric measurements. Select altitude (-100 meters to 2500 meters in increments of 10) and the unit of measurement (mb/hPa or inHg) and press UP or DOWN to change the setting. Press SELECT to confirm.
Rising Steady Falling
14
PS M06 English R19
14
7/16/03, 1:05 PM
WEATHER FORECAST This product forecasts the next 12 to 24 hours of weather within a 30 to 50 km (19 - 31 mile) radius with 70 to 75 percent accuracy. Clear Partly Cloudy Cloudy Rainy
TEMPERATURE AND HUMIDITY With the press of a button, you can check the current indoor or outdoor temperature, humidity percentage, comfort level, trend, and record measurements. VIEW MIN / MAX / CURRENT MEASUREMENTS Press SELECT 3 times until the Temperature and Humidity Areas flash. [. . . ] Problem Temp Calendar Projector Symptom Shows "LLL" or "HHH" Strange date / month No continuous projection No continuous backlight Remedy Temperature is out-ofrange. Change language ( 13) Plug in AC power adapter ( 8, 20) Plug in AC power adapter. ( 8, 19) 23
Problem Radio
Symptom Reception is poor / static
Remedy Select radio format ( 18) Adjust the antenna ( 18) Place clock near a 10) window ( Check batteries ( 8) Check location 10) (
Remote unit
Cannot locate remote unit
Backlight
Cannot change channel
Check sensors. Only one sensor is working ( 16)
PS M06 English R19
23
7/16/03, 1:05 PM
EN
EN
Problem Clock
Symptom Remedy Cannot 1. [. . . ]
DISCLAIMER TO DOWNLOAD THE USER GUIDE OREGON SCIENTIFIC STARCK PSM06A
Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual OREGON SCIENTIFIC STARCK PSM06A will begin.