User manual OREGON SCIENTIFIC RMR136HG

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual OREGON SCIENTIFIC RMR136HG. We hope that this OREGON SCIENTIFIC RMR136HG user guide will be useful to you.


OREGON SCIENTIFIC RMR136HG : Download the complete user guide (245 Ko)

Manual abstract: user guide OREGON SCIENTIFIC RMR136HG

Detailed instructions for use are in the User's Guide.

[. . . ] Multi-Channel Indoor-Ooutdoor Thermohygrometer with Cable FreeTM Sensor & ExactSetTM Clock MODEL: RMR-136HG MAIN UNIT FEATURES CABLE FREE A B I C D E J K L M N Remote Therm-Hygro RMR136HG Tested To Comply With FCC Standards FOR HOME OR OFFICE USE PM C E INTRODUCTION Thank you for purchasing the RMR-136HG Multi-Channel IndoorOutdoor Thermohygrometer with Cable FreeTM sensor, model THGR268, and ExactSetTM calendar clock. This basic configuration consists of the main unit that is the temperature and calendar clock station, and the thermohygrometer sensor remote unit. The main unit has a large easy-read LCD screen that displays the indoor temperature, clock with calendar, and temperature and humidity data transmitted by the remote sensor to the main unit. The RMR-136HG also records the maximum and minimum indoor temperatures, and the maximum and minimum temperatures/humidity data transmitted from the remote sensor. [. . . ] When the remote-sensor mode is active, the main unit LCD scree will display the readings from one channel for approximately 4seconds and then proceed to display the next channel data. To activate the remote-sensor scanning mode: · · Press and hold [CHANNEL] for 2-seconds. To deactivate the remote-sensor scanning mode: TEMPERATURE AND HUMIDITY TREND INDICATOR ICONS The temperature-trend and humidity-trend indicator arrow icons show the trends based on collected readings. Arrow Indicator Temperature Trend Rising Steady Falling MAXIMUM AND MINIMUM TEMPERATURE AND HUMIDITY The maximum and minimum recorded temperature and humidity readings will automatically be stored in the memory. Press [MEMORY] once to display the maximum (MAX) temperature and then again to display the minimum (MIN) temperature. The identifiers of "MAX" and "MIN" will be displayed as appropriate. After clearing the memory, the maximum and minimum temperatures and humidity levels will be the same as current until new data readings are recorded. 7 Arrow Indicator Humidity Trend Rising Steady Falling NOTE: If the temperature exceeds or fall below the temperature measuring range of the main unit or the remote sensor the main unit LCD screen display will show "HHH" or "LLL". See "Specifications" for the temperature measuring ranges. GB GB HOW TO USE CHANNEL-1 TEMPERATURE/HUMIDITY ALARM Maximum and minimum temperature and humidity limits can be set for remote sensor channel-1 so that an alarm sounds when the user-selected limits are exceeded. The maximum and minimum temperatures and humidity are sequentially displayed by pressing [HIGH/LOW]. The High-Low displays are as follows: Sequence Press [HI/LO] X 1 Press [HI/LO] X 2 Press [HI/LO] X 3 Press [HI/LO] X 4 Respective Display Displays the HIGH temperature Displays the HIGH humidity Displays LOW temperature Displays LOW humidity 3. Repeat steps 1 and 2 to set the maximum humidity setting and the minimum temperature and humidity settings. When finished, press [HI/LO] to set another limit or wait 16seconds and the unit will automatically return to the normal display mode. The appropriate HI, LO or both indicators will be displayed indicating the alarm status. When the alarm activates the main unit LCD screen display will automatically switch to channel-1 if in another remote sensor channel mode and will flash. The alarm will automatically reactivate again if the limit continues to exceed the set limits. NOTE: Temperature Range: The temperature range is from -58°F to 158°F (-50°C to 70°C). When setting the limits for the first time, the low/minimum limit will start at -58°F (-50°C) and the high/maximum limit at 158°F (+70°C). The remote sensor is within the effective transmission range of 21 - 32 yards from the main unit. That there are no obstacle (like a transmission tower) or environmental reason (such as a steep hill) that is causing the interference or blockage between the main unit and the remote sensor. If the difficulty continues, reposition the remote sensor to a different location and/or closer to the main unit. INTERRUPTED SIGNALS If the display for a particular remote sensor goes blank on the main unit LCD screen, press [CHANNEL] and [MEMORY] on the main unit at the same time for about 2-seconds to trigger a signal search between the main unit and the remote sensor. The low battery warning icon is not displayed for the main unit or the remote sensor. The remote sensor is within the effective transmission range of 21 to 32 yards from the main unit, and that the transmission path is clear of obstacles and interference. [. . . ] To reactivate signal reception, press [RESET] or remove the batteries, allow the unit to clear all settings and then reinsert the batteries. CUSTOMER ASSISTANCE Should you have questions or require additional information about this product, please contact our Customer Service Department at 800-853-8883 or via email at: www. helpme@oscientific. com Please also visit our website at: www. oregonscientific. com MANUALLY SETTING THE CLOCK The RMR-136HG is an ExactSetTM clock and does not need to be set manually. However, instructions to set the clock manually are included and follow: 1. ] until the WARRANTY Oregon Scientific warrants this product to be free of manufacturing defects for 90 days from date of retail purchase. Defective products should be returned to the place of retail purchase. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE OREGON SCIENTIFIC RMR136HG




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual OREGON SCIENTIFIC RMR136HG will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.