User manual OREGON SCIENTIFIC RM888PA

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual OREGON SCIENTIFIC RM888PA. We hope that this OREGON SCIENTIFIC RM888PA user guide will be useful to you.


OREGON SCIENTIFIC RM888PA : Download the complete user guide (211 Ko)

Manual abstract: user guide OREGON SCIENTIFIC RM888PA

Detailed instructions for use are in the User's Guide.

[. . . ] [MODE] BUTTON Press to change the display mode or press and hold to enter the setting mode D. [ALARM] BUTTON I Press to select the daily alarm function or press and hold to enter the setting mode E. [SNOOZE/ ] BUTTON J G K Press to activate the snooze function or turn on the back-light and projection G. Alarm-on indicator 2 Press to change the default display of the clock I. [. . . ] To deactivate the feature, press and hold the snooze button for 2 seconds again or simply remove the power adapter. Note: Remember to leave the projection lens uncovered when the continuous projection function is being activated. When you are not using the clock projection feature, slide the [LOCK] switch close in order to protect the lens and lock the keys. SECTION 2 THE CALENDAR CLOCK DEFAULT ANALOG CLOCK DISPLAY You can select the local time or home time(the radio-controlled time) as the default analog clock display by using [SWAP] switch hidden inside the battery compartment. When the local time is selected or shown, the icon will be displayed. DIGITAL DISPLAY MODES DC 7. 5V Press [MODE] to display the following in sequence: · · · DC 7. 5V Radio-Controlled Clock Time (same as the default analog clock display) or Local Time. Day of the week Calendar (Month: Day or Day: Month format) 2nd time-zone (Local or home time) · 4 Example of Digital and Analog Display: (Fig. 1) Home-time (Radio-controlled time) - 12:55pm (12:55) Local-time - 5:55pm (17:55) (hour offset = +5 hours) To display the alarm clock and details, press [ALARM]. The daily alarm time will appear in both the analog and the digital displays. Example: ABOUT RADIO RECEPTION The RM888PA will automatically synchronize current time and date with the signal broadcast by the US Atomic Clock when the product is in reception range of the signal. When the unit is new and just out of the box, synchronization with the U. S. The unit will receive the most dependable and interference free signal automatically between Midnight and 4 AM. When the unit is within range of radio signals, its radio-control mechanism will override all manual settings unless the signal reception is manually deactivated. 5 Fig. 1 GB GB When it is receiving radio signal, the radio-reception icon [ ] (strong signal) or [ ] (weak signal) will start to blink. A complete reception generally takes about 2 to 10 minutes, depending on the strength of the radio signal. When the reception is complete, the radio-reception icon will stop blinking and the radio-controlled time will be displayed accordingly. Icon [·] will be displayed if such reception is not successful. For better reception of radio signals, place the clock away from metal objects and electrical appliances to minimize interference. 3. Hold down either button for 2 seconds to rapidly increase or decrease the value. Set the 2nd time-zone off-set hour by entering the hour difference between the local time and home time. Follow the same pattern to set the year, date format (month-day or day-month), month, day, and display language (English [E], German [D], French [F], Italian [I] or Spanish [S]) for day-ofthe-week. HOW TO ENABLE OR DISABLE AUTO-RECEPTION If you wish to disable radio signal auto-reception while the unit is within range, press and hold [ w ] button for 2 seconds. The radio-reception icon on the analog clock display will disappear and the unit will NOT respond to radio signals. The radioreception icon will be shown again and the analog clock display will start blinking to initiate radio signal reception. E Monday Tuesday Wednesday MON TUE WED THR FRI SAT SUN F LUN MAR MER JEU VEN SAM DIM D MON DIE MIT DON FRE SAM SON I LUN MAR MER GIO VEN SAB DOM S LUN MAR MIE JUE VIE SAB DOM HOW TO SET THE CALENDAR CLOCK MANUALLY 1. If changes are made during the process, the seconds will reset and start from zero. The unit will also save all changes and return to normal display automatically after the unit has been left idle for a minute or when [ALARM] is pressed. HOW TO USE THE DAILY ALARM The alarm will go off for 2 minutes in a two-step crescendo pattern. The alarm-on indicators will flash, the back-light and the clock projection will be activated for 5 seconds. [. . . ] Defective product should be directed to the place of retail purchase for exchange. Should this not be possible, contact our customer care department for assistance and a return material authorization. Please retain your retail receipt as you may be asked to provide a copy of it for proof of date purchased. This warranty does not cover product subjected to abuse, misuse, accidental damage or tampering. SPECIFICATIONS Power : 2 pcs of UM-4 or AAA-size 1. 5V batteries Power Adapter (Optional) : 7. 5V DC Weight Dimensions (mm) Accessory : 2. 75 oz. ( 78g ) : 3. 94" x 2. 36" x. 79" (100 x 60 x 20 mm) : Leather pouch for carrying 8 CAUTION - The content of this manual is subject to change without further notice. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE OREGON SCIENTIFIC RM888PA




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual OREGON SCIENTIFIC RM888PA will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.