User manual OREGON SCIENTIFIC RGR682

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual OREGON SCIENTIFIC RGR682. We hope that this OREGON SCIENTIFIC RGR682 user guide will be useful to you.


OREGON SCIENTIFIC RGR682 : Download the complete user guide (864 Ko)

Manual abstract: user guide OREGON SCIENTIFIC RGR682

Detailed instructions for use are in the User's Guide.

[. . . ] Calendar clock / clock alarm / start date of total rainfall record CAUTION Other sensors using the 433 MHz transmission frequency may influence the rainfall reading. Please avoid placing those sensors too close to the unit. RAIN COLLECTOR Remove battery compartment and insert batteries according to polarities. TOTAL RAINFALL The total rainfall is displayed on the 2nd line of the LCD display. To display the commencing date of the total rainfall record, press SINCE. [. . . ] Mount the rain collector on a level surface, positioning it within effective range (100 m / 300 ft) of the main unit. Put drops of water on the cross at the base to check the leveling. DISCONNECTED SIGNALS If without obvious reason the main unit display goes blank, press and hold SEARCH for 2 seconds to enforce an immediate search of the rain collector. LCD SYMBOL DESCRIPTION No signal Searching for signal 1 3 4 2 Water staying at position 1-4 means the gauge is not leveled. Signal connected RGR682_EN. indd 1 2005. 12. 2 2:58:05 PM If that fails, check: · The remote rain collector is still in place. · The batteries of the main unit and rain collector have not run out of power. · The transmission is within range and path is clear of obstacles and interference. Then press SEARCH again. CALENDAR CLOCK The calendar clock is displayed on the bottom line of the display. Press and hold MODE for two seconds and use HISTORY / UP or DOWN to set the desired clock or calendar value. Press and hold MODE for two seconds and use HISTORY / UP or DOWN to set the desired value. When active, the daily alarm will go off for one minute at the set time and the daily alarm indicator will flash. The alarm is still active and will go off at the set time the following day. To deactivate the daily alarm all together: Press ALARM. REMOTE RAIN COLLECTOR (PCR122) RF transmission 433 MHz frequency RF transmission 2. 1 protocol RF transmission range 100 m (300 ft) Operating temperature 1°C to 60°C range (34°F to 140°F) ALARM CLOCK AND CALENDAR Clock HH:MM 12-hour format Calendar Month / Day, Day / Month Alarm 1-min. daily alarm POWER Main unit 2 UM-4 or "AAA" 1. 5V alkaline batteries Rain collector 2 UM-3 or "AA" 1. 5V alkaline batteries WEIGHT Main unit 134 g (4. 71 lbs) Remote rain collector 9. 2 oz (260 g) DIMENSIONS Main Unit 107x 87 x 56 mm LxWxH (4. 2 x 3. 4 x 2. 2 in) Remote rain collector 140 x 145 mm Diam x H (5. 5 x 5. 7 in) NOTE It is recommended that you use alkaline batteries with this product for longer performance. · Consult the dealer or an experienced radio / TV technician for help. DECLARATION OF CONFORMITY The following information is not to be used as contact for support or sales. Please call our customer service number (listed on our website at www. oregonscientific. com), or on the warranty card for this product) for all inquiries instead. 19861 SW 95th Ave. , Tualatin, Oregon 97062 USA 1-800-853-8883 declare that the product Product No. : RGR682 Product Name: Wireless Rain Gauge with 10-Day Rainfall Memory and Digital Clock Manufacturer: IDT Technology Limited Address: Block C, 9/F, Kaiser Estate, Phase 1, 41 Man Yue St. , Hung Hom, Kowloon, Hong Kong is in conformity with Part 15 of the FCC Rules. Operation is subject to the following two conditions: 1) This device may not cause harmful interference. 2) This device must accept any interference received, including interference that may cause undesired operation. ABOUT OREGON SCIENTIFIC Visit our website (www. oregonscientific. com) to learn more about Oregon Scientific products such as digital cameras; MP3 players; children's electronic learning products and games; projection clocks; health and fitness gear; weather stations; and digital and conference phones. The website also includes contact information for our Customer Care department in case you need to reach us, as well as frequently asked questions and customer downloads. [. . . ] Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) This device must accept any interference received, including interference that may cause undesired operation. WARNING Changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment. NOTE This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE OREGON SCIENTIFIC RGR682




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual OREGON SCIENTIFIC RGR682 will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.