User manual OREGON SCIENTIFIC JD BAR898HGA

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual OREGON SCIENTIFIC JD BAR898HGA. We hope that this OREGON SCIENTIFIC JD BAR898HGA user guide will be useful to you.


OREGON SCIENTIFIC JD BAR898HGA : Download the complete user guide (1384 Ko)

Manual abstract: user guide OREGON SCIENTIFIC JD BAR898HGA

Detailed instructions for use are in the User's Guide.

[. . . ] LONG-RANGE WIRELESS WEATHER STATION WITH IN-OUT THERMO-HYGROMETER AND RF CLOCK MODEL : BAR898HGA USER MANUAL INTRODUCTION Congratulations on your purchase of the BAR898HGA LongRange Wireless Weather Station with In-Out Thermo-Hygrometer and RF Clock. This unit is an all-in-one weather forecasting device which has multiple weather-related functions. Also, with an internal antenna the reception range of this unit can be up to 328 feet (100 meters). The BAR898HGA, a weather forecasting device, has several weather related functions. [. . . ] The unit is designed such that you can conveniently use the backlight feature irrespective of whether the unit is wall-mounted or free standing on the table. 6 Wall-Mount Table-Stand For better reception, place the clock away from metal objects and electrical appliances to minimize interference. Should you wish to deactivate the RF controlled function, press and hold the [ZONE] button. To reactivate the RF control function, press and hold the UP [ ] button. Chart Indicating Radio Signal Strength Press the corresponding [ SNOOZE / LIGHT ] button or the button on the stand. The backlight will be activated for 5 seconds. Good No signal Receiving ABOUT RADIO RECEPTION The BAR898HGA is designed to automatically synchronize its calendar clock once it is brought within range of the U. S. When the BAR898HGA is within range, its radio-control mechanism will override all manual settings unless the auto-reception function is manually disabled. When the unit is receiving radio signal, the RADIO RECEPTION signal will start to blink. A complete reception generally takes about 2 to 10 minutes, depending on the strength of the radio signal. When the reception is complete, the RADIO RECEPTION signal will stop blinking. The strength of the reception for the last full hour will be indicated. 7 HOW TO MANUALLY SET THE CLOCK Press [MODE] and hold for three seconds. Holding down either button will increase or decrease the value rapidly. Note: When changes are made to this setting, the seconds will start from zero. Press [MODE] again, the calendar settings are displayed and the year is flashing. Enter the GB GB appropriate month using the UP [ ] or DOWN [ ] button. Press [MODE] button and the day settings will flash. Use the UP [ ] or DOWN [ ] button to select E for English, F for French or S for Spanish. The weekday can be expressed as an abbreviation in three different languages. The languages and their selected abbreviations for each day of the week are shown in the language chart below. Day-of-the-week Language English French Spanish Monday Tuesday Wed. Thursday Friday Saturday Sunday Press UP [ ] or DOWN [ alarm hour setting. ] buttons to make changes to the Press [ALARM] and the minute digits will flash. The ALARM ON icon [ ] is visible and the alarm will be activated at the specified time. To deactivate the daily alarm function, press the [ALARM] button when the alarm time is displayed. To activate, press the [ALARM] button again. ALARM AND SNOOZE FUNCTION When the daily alarm goes off, the backlight will be on for five seconds and the ALARM ON icon [ ] will flash. [. . . ] Do not subject the unit to excessive: force, shock, dust, temperature, or humidity. Such treatment may result in malfunction, a shorter electronic life span, damaged batteries, or distorted parts. Doing so will terminate the unit's warranty and may cause damage. Read this instruction manual thoroughly before operating the unit. Proposed operating range Temperature resolution : -22 °F to 140 °F (-30 °C to 60 °C) : 0. 2°F (0. 1°C) Relative Humidity measurement Measuring Range : 25 to 90%RH at 25°C (77°F) : 1% RH Humidity Resolution SPECIFICATIONS Main unit Indoor Temperature measurement Proposed operating range Temperature resolution : 23. 0°F to 122. 0°F (-5. 0°C to +50. 0°C) : 0. 2°F (0. 1°C) Barometric Pressure measurement Pressure measuring range : 795 to 1050mb / hPa (23. 48 to 31. 01 inHg) Power Main unit : uses four (4) UM-3 or "AA" 1. 5V batteries : uses two (2) UM-3 or "AA" 1. 5V batteries Relative Humidity measurement Measuring Range Humidity Resolution : 25% RH to 95% RH at 25°C (77°F) : 1% RH Weight Main unit Remote sensing unit Remote sensing unit Remote unit RF Transmission Frequency : 433 MHz No. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE OREGON SCIENTIFIC JD BAR898HGA




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual OREGON SCIENTIFIC JD BAR898HGA will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.