User manual OREGON SCIENTIFIC BAR386A

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual OREGON SCIENTIFIC BAR386A. We hope that this OREGON SCIENTIFIC BAR386A user guide will be useful to you.


OREGON SCIENTIFIC BAR386A : Download the complete user guide (1304 Ko)

Manual abstract: user guide OREGON SCIENTIFIC BAR386A

Detailed instructions for use are in the User's Guide.

[. . . ] This clock is supplied with a remote sensor (THN132N) and can support up to 3 sensors in total (additional sensors sold separately). It contains practical step-by-step instructions, as well as technical specifications and warnings you should know about. CLOCK OVERVIEW FRONT VIEW 1. Day and month display REMOTE SENSOR (THN132N) To enable and force a signal search: Press and hold for 2 seconds. Secure the sensor in the desired location using the wall mount or table stand. [. . . ] Wireless ranges can be impacted by a variety of factors such as extremely cold temperatures. Extreme cold may temporarily reduce the effective range between the sensor and the base station. If the unit's performance fails due to low temperature, the unit will resume proper functioning as the temperature rises to within the normal temperature range (i. e. SENSOR DATA TRANSMISSION The sensor reception icon in the remote sensor area shows the status. ICON DESCRIPTION Main unit is searching for the sensor(s) A channel has been found and sensor signal is being received and "- - . ALARM: View alarm status; set alarm BACK VIEW WEATHER FORECAST This product forecasts the next 12 to 24 hours of weather within a 30-50 km (19-31 mile) radius based on barometric pressure trend readings. CHANNEL switch BATTERIES Insert batteries before first use, matching the polarity (+ and -). Press RESET after each battery change. NOTE The maximum operating altitude for weather forecast is 2500m (8202 ft). TEMPERATURE To toggle temperature unit: Press °C / °F. To toggle between current, minimum and maximum records for the selected sensor: Press MEM repeatedly. To clear the records: Press and hold MEM for 2 seconds. To search for a sensor: Simultaneously, press and hold MEM and CHANNEL for 2 seconds. NOTE If the sensor is still not found, check the batteries, obstructions, and remote unit location. 1: 2: 3. 8. / : Increase / decrease setting; activate / deactivate clock reception signal MODE: Change settings / display CHANNEL: Switch remote sensor display MEM: View current, maximum and minimum temperature / humidity °C / °F: Select temperature unit TEMP HI / LO : Change settings or enable / disable hi or lo temperature alarm for channel 1 RESET: Reset unit to default settings Battery compartment indicates main unit batteries are low. We recommend that you use alkaline batteries with this product for longer usage and lithium batteries in temperatures below freezing. CLOCK CLOCK RECEPTION This product is designed to synchronize its date and time automatically once it is within range of the WWVB-60 signal from the atomic clock in Fort Collins, Colorado. The clock collects the radio signals whenever it is within 3219 km (2000 miles) of a signal. REMOTE SENSOR The sensor collects temperature readings approx. The main unit can collect data from up to 3 sensors. BAR386A_M_R6 1 2006. 4. 7, 4:37 PM TEMPERATURE AND PRESSURE TREND The temperature and pressure trend icons are based on recent sensor readings. RISING STEADY FALLING SPECIFICATIONS TYPE MAIN UNIT LxWxH Weight Temperature unit Temperature range Resolution Clock frequency Synchronization Signal frequency Clock Humidity range Humidity resolution Memory Alarm duration Snooze Clock display Hour format Calendar DESCRIPTION 130 x 55 x 112 mm (5. 1 x 2. 1 x 4. 4 in) 176 g (6. 2 oz) without batteries °C / °F -5°C to 50°C (23°F to 122°F) 0. 1°C (0. 2°F) WWVB-60 Auto or disabled 433 MHz Auto or manual (disabled) 25% - 95% 1% Min / Max relative humidity and temperature 2 minutes 8 minutes HH:MM:SS HH:MM: Day of Week 12 / 24 hour format MM / DD or DD / MM language selectable: E, F, D, I and S 3 x UM-3 (AA) 1. 5 V batteries determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: · · · Reorient or relocate the receiving antenna. Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. · Consult the dealer or an experienced radio / TV technician for help. DECLARATION OF CONFORMITY The following information is not to be used as contact for support or sales. Please call our customer service number (listed on our website at www. oregonscientific. com), or on the warranty card for this product) for all inquiries instead. [. . . ] Doing so will invalidate the warranty on the unit and may cause unnecessary damage. · Only use fresh batteries as specified in the user's instructions. · Due to printing limitations, the displays shown in this manual may differ from the actual display. · The contents of this manual may not be reproduced without the permission of the manufacturer. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE OREGON SCIENTIFIC BAR386A




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual OREGON SCIENTIFIC BAR386A will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.