User manual OREGON SCIENTIFIC BAR289

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual OREGON SCIENTIFIC BAR289. We hope that this OREGON SCIENTIFIC BAR289 user guide will be useful to you.


OREGON SCIENTIFIC BAR289 : Download the complete user guide (1084 Ko)

Manual abstract: user guide OREGON SCIENTIFIC BAR289

Detailed instructions for use are in the User's Guide.

[. . . ] 5 Sensor Set Up . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6 Search for Sensor . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6 Clock and Calendar . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6 Set Clock . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . [. . . ] (Refer to the "Sensor Data Transmission" section for more information. ) 7. Secure the sensor in the desired location using the wall mount or table stand. To fold out the stand: To install the remote control batteries: 1 NOTE Do not use rechargeable batteries. UNIT Main Remote Sensor LOCATION Clock / Alarm / Calendar Area Outdoor Temperature Area For best results: · Insert the batteries and select the unit, channel, and radio signal format before you mount the sensor. · Do not place the sensor more than 30 metres (100 feet) from the main (indoor) unit. · Position the sensor so that it faces the main (indoor) unit, minimizing obstructions such as doors, walls, and furniture. · Place the sensor in a location with a clear view to the sky, away from metallic or electronic objects. · Position the sensor close to the main unit during cold winter months as below-freezing temperatures may affect battery performance and signal transmission. NOTE The transmission range may vary and is subject to the receiving range of the main unit. You may need to experiment with various locations to get the best results. 2 NOTE It is recommended that you use alkaline batteries with this product for longer performance. REMOTE SENSOR (RTHR328N) This product is shipped with the RTHR328N Remote Sensor. The THGR328N and THR228N sensors are also compatible with this weather station. Contact your local stockist for more information. ) The RTHR328N sensor collects temperature readings and signals from official time-keeping organizations for the radio-controlled clock. 5 BAR289 ENG R7 OP Black 5 8/20/04, 11:00 PM EN EN SENSOR DATA TRANSMISSION Data is sent from the sensor(s) every 60 Seconds. The reception icon shown in the Outdoor Temperature Area indicates the status. (The number shows which sensor is selected. ) --- shows in Temp Area The selected sensor cannot be found. Search for the sensor or check batteries. · RF signal reception ( ) How these signals work together: ICON MEANING The unit has contact with the remote sensor and has synchronized the time. The unit has contact with the remote sensor but the time has not been synchronized. The unit has lost contact with the remote sensor but the time is synchronized. The unit has lost contact with the remote sensor and the time is not synchronized. The unit cannot reach the remote sensor. SELECT SENSOR CHANNEL Press CHANNEL on the main unit, to switch between sensors 1-5. NOTE To force a manual search for the RF clock reception, press and hold SEARCH on the sensor (RTHR328N). TURN RADIO-CONTROLLED CLOCK ON / OFF To auto-scan between sensors, press and hold CHANNEL for 2 seconds. SEARCH FOR SENSOR To search for a Thermo sensor, simultaneously press and hold CHANNEL and MEMORY for 2 seconds. If you wish to manually set the clock, you must first disable the radio-controlled feature. [. . . ] Remove the batteries if storing this product for a long period of time. Do not scratch the LCD display. Remote Sensor Dimensions LxWxH Weight 70 x 24. 5 x 116 mm (2. 76 x 0. 96 x 4. 57 inches) 108 grams (0. 24 lbs) without battery Temperature Unit Indoor Range Outdoor Range Resolution Memory Weather Forecast Display °C or °F -5°C to 50°C (23°F to 122°F) -20°C to 60°C (-4°F to 140°F) 0. 1°C (0. 2°F) Min / Max Sunny (day / night), partly cloudy (day / night), cloudy, rainy, snowy NOTE The technical specification of this product and contents of this user manual are subject to change without notice. Images not drawn to scale. TROUBLESHOOTING PROBLEM Calendar Clock SYMPTOM Strange date / month Cannot adjust clock Cannot autosynch REMEDY Change language ( 6) Disable radiocontrolled clock ( 1. Manually activate radio-controlled clock ( 6) Temp Remote sensor Shows "LLL" or "HHH" Cannot locate remote sensor Temperature is out-ofrange Check batteries ( 5) 6) Remote Unit (RTHR328N) RF frequency 433 MHz Range Up to 30 metres (100 feet) with no obstructions Transmission Approx. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE OREGON SCIENTIFIC BAR289




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual OREGON SCIENTIFIC BAR289 will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.