User manual OREGON SCIENTIFIC BAR182HG

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual OREGON SCIENTIFIC BAR182HG. We hope that this OREGON SCIENTIFIC BAR182HG user guide will be useful to you.


OREGON SCIENTIFIC BAR182HG : Download the complete user guide (371 Ko)

Manual abstract: user guide OREGON SCIENTIFIC BAR182HG

Detailed instructions for use are in the User's Guide.

[. . . ] [ I ] BUTTON ( TEMP/% RH ALARM ) Advances the value of the settings for the HI / LO temperature and humidity alarm. BATTERY COMPARTMENT Accommodates four (4) UM-3 or AA size batteries REMOVABLE TABLE STAND For standing the main unit on a flat surface H. [ MEM ] BUTTON Displays minimum and maximum temperature and humidity readings, and erases memory data I. [ CHANNEL ] BUTTON Toggles among the remote sensor channels CLOCK : J. [. . . ] This is normal and does not affect the general performance of the product. The transmission and reception of temperature and humidity readings will resume once the interference recedes. To display temperature / humidity readings from the main unit: Press [CHANNEL] until a dot is displayed in the box under the kinetic-wave. 6 HOW TO READ THE KINETIC WAVE DISPLAY The kinetic wave display shows the signal receiving status of the main unit. No signal received in search mode. THE COMFORT-LEVEL ICONS The comfort level indicators COM, WET or DRY will tell you if the current environment is comfortable, too wet or too dry. The comfort indicator will appear on the display when the following conditions are satisfied: Indicator displays on the unit Temperature Range Humidity Range Shows that the Current Environment Ideal range for both relative humidity and temperature Contains excess moisture. Contains inadequate moisture No comment COM 20°C to 25°C 40%RH(68°F to 77°F) 70%RH -5°C -+ 50°C OVER(23°F - 122°F) 70%RH -5°C -+ 50°C Below (23°F - 122°F) 70%RH Less than 20°C( 68°F) or More than 25°C (77°F) 40%RH to 70%RH REMOTE SENSOR SCANNING The unit can be set to automatically scan and display readings from the remote sensors and indoor readings. When the remote-sensor mode is active, the display will show the readings from one channel for about 4-second and then proceed to the next channel display. To activate the remote-sensor scanning mode: Press and hold [CHANNEL] for 2-seconds. To deactivate the remote-sensor scanning mode: Press either [CHANNEL], [MEM], [HI/LO], [ I ], [ ON / OFF] WET DRY No Indicator (TEMP % RH AL) 7 GB GB TEMPERATURE, HUMIDITY & PRESSURE TREND INDICATORS The temperature-trend, humidity-trend and pressure trend indicators show the trends of collected readings. Arrows indicate a rising, steady or falling trend. Arrow indicator Temperature Trend Rising Steady Falling MAXIMUM AND MINIMUM TEMPERATURE AND HUMIDITY The maximum and minimum recorded temperature and humidity readings will automatically be stored in the memory. Press [MEM] once to display the maximum temperature and humidity and again the minimum temperature and humidity. If you press [MEM] now, the maximum and minimum recordings will have the same values as the current ones until different readings are recorded. Arrow indicator Humidity Trend Rising Steady Falling Arrow indicator Steady Falling HOW TO USE CHANNEL-1 TEMPERATURE/ HUMIDITY ALARM Rising Pressure Trend Upper and lower temperature and humidity limits for channel-1 can be set so that an alarm activates when the limits are exceeded. The high and low temperature and humidity displays are selected by sequentially pressing [ HI/LO ]. Note: If the readings goes above or below the measuring range of the main unit or the remote unit ( stated in specification), the display will show HHH or LLL. 8 The high-low displays are as follows: Sequence Pressing HI/LO once Pressing HI/LO twice Pressing HI/LO third time Pressing HI/LO fourth time Respective Display Enters HI temperature display Enters HI humidity display Enters LO temperature display Enters LO humidity display The respective HI, LO or both indicators will light up to signify the status of the alarm. If in another channel other than channel one is selected, when the alarm activates the display will switch to channel-1 and the display will flash. Press [CHANNEL], [MEM], [HI/LO], [I], [ ON / OFF] to (TEMP % RH AL) momentarily stop the alarm. The alarm will activate again if the limit continues to exceed the set limit. Note: If a second limit is passed while an alarm is active, the first alarm will complete its 1-minute cycle and the alarm will continue to activate for a second minute to indicate that a second limit has been surpassed. The alarm has been disabled and will not sound at the previously set limit. To disable a sounding alarm: Press either [CHANNEL], [MEM], [HI/LO], [ I ], [ ON / OFF] To set a high or low temperature or humidity alarm: 1. Press and hold the button for a rapid-scrolling sequence by increments of five. Note: The temperature range is from -50°C (-58°F) to +70°C (158°F). [. . . ] If the unit comes in contact with water, dry it immediately with a soft lint-free cloth. Abrasive cleaning agents may scratch the plastic parts and corrode the electronic circuit. Do not subject the unit to excessive: force, shock, dust, temperature, or humidity. Such treatment may result in malfunction, a shorter electronic life span, damaged batteries, or distorted parts. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE OREGON SCIENTIFIC BAR182HG




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual OREGON SCIENTIFIC BAR182HG will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.