User manual OMRON ZS-MDC V2.0

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual OMRON ZS-MDC. We hope that this OMRON ZS-MDC user guide will be useful to you.


OMRON ZS-MDC V2.0: Download the complete user guide (4435 Ko)

You may also download the following manuals related to this product:

   OMRON ZS-MDC (4443 ko)
   OMRON ZS-MDC (4591 ko)

Manual abstract: user guide OMRON ZS-MDCV2.0

Detailed instructions for use are in the User's Guide.

[. . . ] Z209-E2-01 ZS-MDC (Ver 2. 0) Smart Sensors Multi-Controller USER'S MANUAL Introduction Section 1 Section 2 Section 3 Section 4 Section 5 , Í, ¶, ß, É `æ 1 Í `æ 2 Í `æ 3 Í `æ 4 Í INTRODUCTION APPLICATION CONSIDERATIONS (Please Read) SECTION 1 FEATURES SECTION 2 INSTALLATION & CONNECTION SECTION 3 SETUP SECTION 4 APPLICATION SETTING EXAMPLES SECTION 5 APPENDIX Section User's Manual Smart Sensors Multi-Controller ZS-MDC Introduction Introduction READ AND UNDERSTAND THIS DOCUMENT Please read and understand this document before using the products. Please consult your OMRON representative if you have any questions or comments. WARRANTY OMRON's exclusive warranty is that the products are free from defects in materials and workmanship for a period of one year (or other period if specified) from date of sale by OMRON. OMRON MAKES NO WARRANTY OR REPRESENTATION, EXPRESS OR IMPLIED, REGARDING NON-INFRINGEMENT, MERCHANTABILITY, OR FITNESS FOR PARTICULAR PURPOSE OF THE PRODUCTS. ANY BUYER OR USER ACKNOWLEDGES THAT THE BUYER OR USER ALONE HAS DETERMINED THAT THE PRODUCTS WILL SUITABLY MEET THE REQUIREMENTS OF THEIR INTENDED USE. [. . . ] is displayed flashing. 1 OFF 2ON 3. Press function key 2 representing [ON]. The "Complete!" message is displayed. 4. SMOOTH Complete! : ON Press the MENU key to return to the top menu. Pressing the ESC key returns to the previous menu. 3-6 ZS-MDC User's Manual Section 3 About Setup RUN Mode In this mode, measured values are displayed on the main display, and threshold values and other information are displayed on the sub-display. Pressing the MENU key displays the display customize menu. Measured value display MAIN : MESURE SUB : THRESH MAIN : MESURE SUB : VOLTAGE Section 3 SETUP MAIN : MESURE SUB : DISTANCE MAIN : MESURE SUB : RESOLU Display customise menu 1 DIGITAL 3 HELP 2 LCD Details displayed on the sub-display Display Details THRESH VOLTAGE (CURRENT) Description Displays the HIGH/LOW threshold values according to the setting of the threshold switch. The display details change according to the setting of the current/voltage switch. These values differ from actual linear output values. ) Displays the fluctuation width (peak to peak) of the measured value over a fixed amount of time. Displays the measured value before it is processed by hold or other functions. RESOLU DISTANCE Key Operations Key Function keys Measured Value Display Not used Display Customize Menu Directly select functions. LEFT key RIGHT key Changes sub-display content. The function changes depending on the settings. · Selects digits. User's Manual ZS-MDC 3-7 Section 3 About Setup Key UP key DOWN key Measured Value Display Display Customize Menu UP key: Executes trigger input. Applies numerical value settings. MENU key SET key ESC key Hold down for at least two seconds to cancel a zero reset. Returns to the previous menu. When the top menu is displayed, returns to the measured value display. Section 3 SETUP TEACH Mode In this mode, the measured value is displayed at all times on the main display. Which of the HIGH or LOW threshold values is displayed changes according to the setting of the threshold selector switch. TEACH MODE MENU : TEACHING TEACH MODE : DIRECT IN Displayed alternately Key Operations Key Function keys Not used TEACHING Not used DIRECT IN LEFT key RIGHT key UP key DOWN key Not used Not used Selects the digit in the threshold numerical value. Changes the threshold numerical value. MENU key Registers the measured value when this key is pressed as the threshold value. Not used Not used SET key Applies the newly set threshold value. Cancels the newly set threshold value. ESC key Not used 3-8 ZS-MDC User's Manual Section 3 About Setup List of Setting Items This manual describes only "FUN Mode-[SENSING]" functions unique to the Multi-Controller. Details of other functions are the same as those for the Sensor Controller. Refer to the Sensor Controller Userís Manual. FUN Mode This is the mode for setting the measurement conditions. When TASK1 is selected, all items including items common to all tasks can be set. When a task other than TASK1 is selected, only items specific to that task can be set. Section 3 SETUP When TASK1 is selected Settings SEL CH CALC Default Value CH FUN Mode SENSING Option/Range Input A to input I Pages p. 3-14 OFF, CH (input A to input I), CALC p. 3-15 (THICK, STEP, K+mX+nY, AVE, MAX-MIN) OFF, ON - FILTER SMOOTH AVERAGE DIFF ON 1 OFF OFF OFF 1, 2, 4, 8, 16, 32, 64, 128, 256, 512, 1024, 2048, 4096 OFF, ON OFF, ON (AUTO, MAN) - OUTPUT HOLD SCALING TYPE OFF, PEAK, BOTTOM, P-P, AVERAGE, SAMPLE EXT, SELF-UP, SELF-DN OFF, ON (T-DELAY, T-TIME) REAL, HOLD -999. 99 to 999. 999 - TRIGGER DELAY 0RESET TYPE OFFSET EXT OFF REAL 0 User's Manual ZS-MDC 3-9 Section 3 About Setup Settings I/O SET JUDGE NO-MEAS HYS TIMER Default Value CLAMP 20 µm OFF Option/Range KEEP, CLAMP 0 to 999. 999 OFF, OFF DELAY (1 to 5000ms), ON DELAY (1 to 5000ms), ONE SHOT (1 to 5000ms) OFF, ON OFF, ON (-999 to 999) OFF, ON OFF, ON OFF, ON OFF, ON TASK (TASK1 to 4, ALL TASK, NONE), FUNC (NORMAL, BANK) TASK1 to TASK4, NONE TASK1 to TASK4, NONE LOG1 to 9(NONE, INPUT A to INPUT I, TASK1 to TASK4) BANK1, BANK2, BANK3, BANK4 (Initializes bank settings. ) (Saves Multi-Controller settings. ) (Initializes Multi-Controller settings. ) Pages - ANALOG FOCUS ADJUST OFF OFF ON ON ON ON TASK TASK1 TASK1 - - INPUT IN0 IN1 IN2 IN3 Section 3 SETUP BANK SYSTEM I/O SET IN OUT ANALOG DIGITAL CHANGE CLEAR SAVE INIT p. 3-16 BANK1 - - INFO CYCLE VERSION 8BIT NONE 1BIT 38400 CR COMPWAY 0 OFF OFF Japanese (Displays the current measurement cycle. ) (Displays the Multi-Controller version. ) 8BIT, 7BIT NONE, ODD, EVEN 1BIT, 2BIT 9600, 19200, 38400, 57600, 115200 CR, LF, CR+LF COMPWAY, NORMAL 0 to 16 OFF, ON OFF, ON Japanese, English - COM (RS-232C) LENGTH PARITY STOP BAUDRAT DELIMIT COM MODE NODE KEYLOCK ZERORST LANGUAG 3-10 ZS-MDC User's Manual Section 3 About Setup When other than TASK1 is selected Settings CALC Default Value CH FUN Mode SENSING Option/Range OFF, CH(input A to input I), CALC (THICK, STEP, K+mX+nY, AVE, MAX-MIN) OFF, ON Page s p. 3-15 FILTER SMOOTH AVERAGE DIFF ON 1 OFF OFF OFF - 1, 2, 4, 8, 16, 32, 64, 128, 256, 512, 1024, 2048, 4096 OFF, ON OFF, ON (AUTO, MAN) - Section 3 SETUP OUTPUT HOLD SCALING TYPE - OFF, PEAK, BOTTOM, P-P, AVERAGE, SAMPLE EXT, SELF-UP, SELF-DN OFF, ON (T-DELAY, T-TIME) REAL, HOLD -999. 99 to 999. 999 - TRIGGER DELAY 0RESET TYPE OFFSET BANK (same as when TASK1 is selected) EXT OFF REAL 0 SYSTEM (same as when TASK1 is selected) User's Manual ZS-MDC 3-11 Section 3 About Setup RUN Mode In the RUN mode, you can customize the details that are displayed in the digital displays. To call the display customize menu, press the MENU key in the RUN mode. RUN mode DIGITAL DOT ECO LCD ON/OFF B. LIGHT CUSTOM Settings Default Value 3 NORMAL ON ON U-OFF D-OFF 0 to 5 NORMAL, ECO, OFF ON, AUTOOFF, OFF ON, AUTOOFF, OFF U-ON/OFF, L-ON/OFF Upper section customize, lower section customize - Option/Range Page s - Section 3 SETUP HELP - - TEACH Mode This is the mode for setting the threshold values TEACH Mode Settings TEACHING DIRECT IN Default Value - Option/Range Page s - 3-12 ZS-MDC User's Manual Section 3 Selecting Tasks Selecting Tasks By assigning expressions to "tasks, " you can process (multi-tasking) multiple logic operations (max. After selecting the task in the task selection menu, make the various settings for the selected task in the respective setup menus. Press the ESC key with the FUN Mode-TOP menu displayed. Setting TASK1 TASK2 TASK3 TASK4 Description Selects TASK1 as the destination to store the expression to. [. . . ] · When two-point scaling has been executed, the distance between the measured values for the two points is not 1% or more of the rated measuring range. Monitor focus settings cannot be made when the distance between the two specified points is not 1% or more of the rated measuring range. When focusing is executed, an error appears and settings cannot be made. Section 5 APPENDIX 5-4 ZS-MDC User's Manual Section 5 Glossary Glossary Term Measured value Explanation The measured value is the operation result displayed on the main display of the Multi-Controller in the RUN and TEACH modes. hold) has been processed. p. 3-7 Present value The present value is the current measurement result for the target Multi-Controller. Press the LEFT or RIGHT Key in the RUN mode to display the present value on the subdisplay. p. 3-7 Judgment output "Judgment output" is a general term for the HIGH, PASS, and LOW outputs. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE OMRON ZS-MDC




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual OMRON ZS-MDC will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.