Manual abstract: user guide OMRON ZS-DSU
Detailed instructions for use are in the User's Guide.
[. . . ] Z210-E2-01
ZS-DSU (Ver 1. 0)
Smart Sensors
Data Storage Unit
USER'S MANUAL
Introduction Section 1 Section 2 Section 3 Section 4 Section 5 Section 6 , Í, ¶, ß, É `æ 1 Í `æ 2 Í `æ 3 Í `æ 4 Í
Introduction APPLICATION CONSIDERATIONS (Please Read)
Section 1 FEATURES
Section 2 INSTALLATION & CONNECTION
Section 3 SETUP
Section 4 EXTERNAL I/O
Section 5 APPLICATION SETTING EXAMPLES
Section 6 APPENDIX
User's Manual
Smart Sensor Data Storage Unit ZS-DSU
Introduction
Introduction
READ AND UNDERSTAND THIS DOCUMENT
Please read and understand this document before using the products. Please consult your OMRON representative if you have any questions or comments.
WARRANTY
OMRON's exclusive warranty is that the products are free from defects in materials and workmanship for a period of one year (or other period if specified) from date of sale by OMRON. OMRON MAKES NO WARRANTY OR REPRESENTATION, EXPRESS OR IMPLIED, REGARDING NON-INFRINGEMENT, MERCHANTABILITY, OR FITNESS FOR PARTICULAR PURPOSE OF THE PRODUCTS. ANY BUYER OR USER ACKNOWLEDGES THAT THE BUYER OR USER ALONE HAS DETERMINED THAT THE PRODUCTS WILL SUITABLY MEET THE REQUIREMENTS OF THEIR INTENDED USE. [. . . ] Range: UP, DOWN (default: UP)
Section3 SETUP
DELAY
Trigger level Measured value At up edge Logging start At down edge Logging start
Set the delay time when you want to start logging a little before or a little after the start trigger. Range: -9999 to 9999 (ms) (default value: 0 ms)
-9999ms
Delay time
+9999ms Trigger level Measured value
Start trigger At -9999ms At 9999ms Logging start Logging start
3-18
ZS-DSU
User's Manual
Section3 Setting the Logging Conditions
DATA WINDOW
This item is for setting the change in the state of the data (measured value) as the logging start trigger. When the measured value falls inside or outside of that range, this is taken to be the start trigger. FUN Mode-[LOGGING]-[TRIGGER]-[START]-[WINDOW]
Setting SOURCE UPPER LOWER MODE Description Select the source to be used as the logging start trigger. Range: SourceA to J Sets the upper limit value of the specified range. Range: -999. 999 to 999. 999 Sets the lower limit value of the specified range. Range: -999. 999 to 999. 999 Select either of the measured value inside or outside the specified range is to be used as the start trigger. Range: IN, OUT (default: IN)
Section3 SETUP
Measured value Specified range
At IN At OUT
DELAY
Logging start Logging start
Set the delay time when you want to start logging a little before or a little after the start trigger. Range: -9999 to 9999 (ms) (default value: 0 ms)
-9999ms
Delay time
+9999ms Measured value Specified range
At -9999ms At 9999ms
Start trigger Logging start Logging start
User's Manual
ZS-DSU
3-19
Section3 Setting the Logging Conditions
I/O RESULT
Set this item when you want to apply a trigger by the input result (e. g. trigger input) from a controller on a specific CH assigned as the source or by the output result (HIGH/ PASS/LOW/, etc. ). FUN Mode-[LOGGING]-[TRIGGER]-[START]-[I/O]
Setting SOURCE I/O SEL Description Select the source to be used as the logging start trigger. Range: SourceA to J Select which I/O signal on the channel assigned as the selected source is to be used as the start trigger. Range: IN0 to IN3, OUT0 to OUT4 Sets the change in state of the signal, from ON to OFF or from OFF to ON, to be taken as the trigger. Range: OFF ON, ON OFF (default value: OFF ON)
Section3 SETUP
ACTIVE
ON OFF At OFF At ON ON Logging start OFF Logging start
DELAY Set the delay time when you want to start logging a little before or a little after the start trigger. Range: -9999 to 9999 (ms) (default value: 0 ms)
-9999ms
Delay time
+9999ms
Measured value
Start trigger At -9999ms At 9999ms Logging start Logging start
3-20
ZS-DSU
User's Manual
Section3 Setting the Logging Conditions
HOUR
This item is for setting the time (hours, minutes, seconds) that logging is to be started. The system clock must be set on the ZS-DSU beforehand.
Setting the System Clock p. 3-34
FUN Mode-[LOGGING]-[TRIGGER]-[END]-[HOUR]
<When set at 9:00:00> 8:00 8:30 9:00 9:30
Section3 SETUP
Logging start
Setting the end trigger
Set the conditions for ending logging.
Select one of "BUTTON, EXT, DATA, WINDOW, I/O, HOUR, TIME, QUANT" as the end trigger. The default value is [BUTTON].
BUTTON
This setting item is for inputting the end trigger by key operation on the ZS-DSU. FUN Mode-[LOGING]-[TRIGGER]-[END]-[BUTTON]
The UP key is pressed
Logging end
User's Manual
ZS-DSU
3-21
Section3 Setting the Logging Conditions
EXT INPUT SLOPE
This item is for setting the external input signal as the logging end trigger. FUN Mode-[LOGGING]-[TRIGGER]-[END]-[EXT]
Setting EDGE Description Select at which timing, ON or OFF, of the timing signal that logging is to end. Range: OFF ON, ON OFF (default value: OFF ON)
Delays end of logging by about 1. 2 ms at most from input of the external trigger.
Section3 SETUP
Timing input At OFF At ON
ON OFF ON Logging end OFF Logging end 1. 2ms 1. 2ms
DATA SLOPE
This item is for setting the change in the state of the data (measured value) as the logging end trigger. When the data falls above or below this preset trigger level value, this is taken to be the end trigger. FUN Mode-[LOGING]-[TRIGGER]-[END]-[DATA]
Setting ASSIGN EDGE Description Select the source to be used as the logging end trigger. [. . . ] The Data Storage Unit is turned ON again and restored after it is initialized. Turn the Data Storage Unit ON again.
SYSTEM ERROR MAIN COM
Internal error
Others
Display Details LCD screen Disp range Error Cause Countermeasure Change the decimal point digit The measurement result exceeds the number of dis- setting. played digits.
User's Manual
ZS-DSU
6-3
Section6 APPENDIX
Q&A
Question What is the minimum sampling interval?Answer This changes according to the number of assigned sources and mode.
p. 3-26
Can I use third-party Memory Cards? [. . . ]