Introduction
Thank you for purchasing the ZG2 series. This manual provides information regarding functions, performance and operating methods that are required for using the ZG2. When using the ZG2, be sure to observe the following: · The ZG2 must be operated by personnel knowledgeable in electrical engineering. · To ensure correct use, please read this manual thoroughly to deepen your understanding of the product. [. . . ] value
Output
Sampling period P-P The "difference between the max. The output measurement value is held at the same value for one sampling period, that is, until the next sampling period ends. value)
Sampling period
112
Adjusting the Output Conditions of the Measurement Result
ZG2 User's Manual
Setting value
AVERAGE
Description
The "average of the measurement values" in the sampling period is held. The output measurement value is held at the same value for one sampling period, that is, until the next sampling period ends. Current measurement value Sampling period Output (average value)
SAMPLE
The measurement value instantaneously obtained at the start of the sampling period is held. The output measurement value is held at the same value between two sampling periods, that is, until the next sampling period starts. Current measurement value Sampling period Output
ZG2 User's Manual
Adjusting the Output Conditions of the Measurement Result
113
3
FUNCTION SETTINGS
Setting Zero Reset
Setting the Offset Value
To set a reference value for zero reset to a value other than 0 (zero), set the offset amount using this function. Executing Reference Zero Reset p. 115
ADJ mode-MENU/VIEW key-[OUT]-[ZERO]
Setting value
ZERO
Description
Sets the offset amount. Range: -999. 99999 to +999. 99999 (default value: 0)
Note
To change numerical values, use the key/ key, and to change the number of digits use the key/ key.
114
Setting Zero Reset
ZG2 User's Manual
Executing Reference Zero Reset
When the zero reset function is used, the reference value "0" is registered as the height, and the measured value can be displayed and output as a positive or negative deviation (tolerance) from the reference value. In the RUN mode, the measured value can be reset to "0" at any time during measurement.
1 2
Switch to the RUN mode. Set the object to be used as the reference in place.
3
(reference value)
FUNCTION SETTINGS
Zero Reset indicator
3
Press the SET key. The Zero Reset indicator lights, and the current measured value is registered as 0 (zero).
Note
· To cancel a zero reset, press and hold the ESC key for 2 seconds or longer. · Zero reset can also be executed and canceled by an external input. · A value other than zero also can be set as the zero reset reference value.
Setting the Offset Value p. 114
ZG2 User's Manual
Setting Zero Reset
115
Bank Settings
The ZG2 can hold up to 16 sets of settings, which are called a "bank". Bank 1 is displayed as the default bank when the Smart Sensor is turned ON. Tasks and Bank Data p. 53
Bank Switching (change of device setup)
The currently selected bank can be switched to other banks. Switching of banks is instructed by operating Controller keys, external signals or communication commands.
FUN mode-[BANK]-[SWITCH]
Setting value
BANK1 to BANK16
Description
Selects the target bank. (default value: BANK1)
Note
Switching banks by external signals p. 129 Switching banks by communication commands p. 160
Copying Bank Data
The settings of other banks can be copied to the current bank.
FUN mode-[BANK]-[COPY]
Setting value
BANK1 to BANK16
Description
Selects the copy source bank. (default value: BANK1)
Important
After executing a bank copy, switch to the RUN mode once to save the settings. Settings are cleared when the Smart Sensor is turned OFF after you just copy the settings.
116
Bank Settings
ZG2 User's Manual
Clearing Bank Data
The content of banks can be cleared.
Important
Settings in [System] and [I/O] are not cleared.
FUN mode-[BANK]-[CLEAR]
Setting value
YES NO
Description
The content of the currently selected bank is cleared. The content of the currently selected bank is not cleared.
ZG2 User's Manual
Bank Settings
117
3
FUNCTION SETTINGS
System Settings
Setting the Sensor Head Installation Status
Regular Reflection/Diffuse Reflection
Set how the Sensor Head is installed. This setting is automatically specified according to the type of the connected Sensor Head. [. . . ] Class IIIb products include laser systems ranging from 5 to 500 milliwatts in the visible spectrum. Class IIIb emission levels are ocular hazards for direct exposure throughout the range of the Class, and skin hazards at the higher levels of the Class.
ANSI description Class 3 lasers are divided into two subclasses, 3a and 3b. A Class 3 laser may be hazardous under direct and specular reflection viewing conditions, but the diffuse reflection is usually not a hazard.
Class IIIb/3b
Class IV/4
Exceeding the limits of Class IIIb and are a A Class 4 laser is a hazard to the eye or skin hazard for scattered reflection as well as for from the direct beam and sometimes from a direct exposure. Class 4 lasers may also produce laser-generated air contaminants and hazardous plasma radiation.
230
Requirements from Regulations and Standards
ZG2 User's Manual
Compliance with EC Directives
CE marking Applicable directive Low-Voltage directive
Compliance (*1)
*1
Safety category EMC directive
Complied (*1) B
Exception
For details of detailed compliance levels, we have issued the "EC Declaration of Conformity: EN45014. " Please contact your OMRON sales representative.
ZG2 User's Manual
Compliance with EC Directives
231
6
APPENDICES
Updating the Firmware
This section describes how to update the firmware of ZG2 series Controllers (such as ZG2-WDC). [. . . ]
DISCLAIMER TO DOWNLOAD THE USER GUIDE OMRON ZG2