User manual OMRON ZG2

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual OMRON ZG2. We hope that this OMRON ZG2 user guide will be useful to you.


OMRON ZG2 : Download the complete user guide (6393 Ko)

You may also download the following manuals related to this product:

   OMRON ZG2 DATASHEET (739 ko)

Manual abstract: user guide OMRON ZG2

Detailed instructions for use are in the User's Guide.

[. . . ] Z288-E1-01 ZG2 Series Smart Sensor 2D Profile Measuring Sensors USERS MANUAL Introduction Thank you for purchasing the ZG2 series. This manual provides information regarding functions, performance and operating methods that are required for using the ZG2. When using the ZG2, be sure to observe the following: · The ZG2 must be operated by personnel knowledgeable in electrical engineering. · To ensure correct use, please read this manual thoroughly to deepen your understanding of the product. [. . . ] value Output Sampling period P-P The "difference between the max. The output measurement value is held at the same value for one sampling period, that is, until the next sampling period ends. value) Sampling period 112 Adjusting the Output Conditions of the Measurement Result ZG2 User's Manual Setting value AVERAGE Description The "average of the measurement values" in the sampling period is held. The output measurement value is held at the same value for one sampling period, that is, until the next sampling period ends. Current measurement value Sampling period Output (average value) SAMPLE The measurement value instantaneously obtained at the start of the sampling period is held. The output measurement value is held at the same value between two sampling periods, that is, until the next sampling period starts. Current measurement value Sampling period Output ZG2 User's Manual Adjusting the Output Conditions of the Measurement Result 113 3 FUNCTION SETTINGS Setting Zero Reset Setting the Offset Value To set a reference value for zero reset to a value other than 0 (zero), set the offset amount using this function. Executing Reference Zero Reset p. 115 ADJ mode-MENU/VIEW key-[OUT]-[ZERO] Setting value ZERO Description Sets the offset amount. Range: -999. 99999 to +999. 99999 (default value: 0) Note To change numerical values, use the key/ key, and to change the number of digits use the key/ key. 114 Setting Zero Reset ZG2 User's Manual Executing Reference Zero Reset When the zero reset function is used, the reference value "0" is registered as the height, and the measured value can be displayed and output as a positive or negative deviation (tolerance) from the reference value. In the RUN mode, the measured value can be reset to "0" at any time during measurement. 1 2 Switch to the RUN mode. Set the object to be used as the reference in place. 3 (reference value) FUNCTION SETTINGS Zero Reset indicator 3 Press the SET key. The Zero Reset indicator lights, and the current measured value is registered as 0 (zero). Note · To cancel a zero reset, press and hold the ESC key for 2 seconds or longer. · Zero reset can also be executed and canceled by an external input. · A value other than zero also can be set as the zero reset reference value. Setting the Offset Value p. 114 ZG2 User's Manual Setting Zero Reset 115 Bank Settings The ZG2 can hold up to 16 sets of settings, which are called a "bank". Bank 1 is displayed as the default bank when the Smart Sensor is turned ON. Tasks and Bank Data p. 53 Bank Switching (change of device setup) The currently selected bank can be switched to other banks. Switching of banks is instructed by operating Controller keys, external signals or communication commands. FUN mode-[BANK]-[SWITCH] Setting value BANK1 to BANK16 Description Selects the target bank. (default value: BANK1) Note Switching banks by external signals p. 129 Switching banks by communication commands p. 160 Copying Bank Data The settings of other banks can be copied to the current bank. FUN mode-[BANK]-[COPY] Setting value BANK1 to BANK16 Description Selects the copy source bank. (default value: BANK1) Important After executing a bank copy, switch to the RUN mode once to save the settings. Settings are cleared when the Smart Sensor is turned OFF after you just copy the settings. 116 Bank Settings ZG2 User's Manual Clearing Bank Data The content of banks can be cleared. Important Settings in [System] and [I/O] are not cleared. FUN mode-[BANK]-[CLEAR] Setting value YES NO Description The content of the currently selected bank is cleared. The content of the currently selected bank is not cleared. ZG2 User's Manual Bank Settings 117 3 FUNCTION SETTINGS System Settings Setting the Sensor Head Installation Status Regular Reflection/Diffuse Reflection Set how the Sensor Head is installed. This setting is automatically specified according to the type of the connected Sensor Head. [. . . ] Class IIIb products include laser systems ranging from 5 to 500 milliwatts in the visible spectrum. Class IIIb emission levels are ocular hazards for direct exposure throughout the range of the Class, and skin hazards at the higher levels of the Class. ANSI description Class 3 lasers are divided into two subclasses, 3a and 3b. A Class 3 laser may be hazardous under direct and specular reflection viewing conditions, but the diffuse reflection is usually not a hazard. Class IIIb/3b Class IV/4 Exceeding the limits of Class IIIb and are a A Class 4 laser is a hazard to the eye or skin hazard for scattered reflection as well as for from the direct beam and sometimes from a direct exposure. Class 4 lasers may also produce laser-generated air contaminants and hazardous plasma radiation. 230 Requirements from Regulations and Standards ZG2 User's Manual Compliance with EC Directives CE marking Applicable directive Low-Voltage directive Compliance (*1) *1 Safety category EMC directive Complied (*1) B Exception For details of detailed compliance levels, we have issued the "EC Declaration of Conformity: EN45014. " Please contact your OMRON sales representative. ZG2 User's Manual Compliance with EC Directives 231 6 APPENDICES Updating the Firmware This section describes how to update the firmware of ZG2 series Controllers (such as ZG2-WDC). [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE OMRON ZG2




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual OMRON ZG2 will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.