User manual OMRON ZFX-C-CD APPENDIX

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual OMRON ZFX-C-CD. We hope that this OMRON ZFX-C-CD user guide will be useful to you.


OMRON ZFX-C-CD APPENDIX: Download the complete user guide (394 Ko)

You may also download the following manuals related to this product:

   OMRON ZFX-C-CD APPENDIX (558 ko)

Manual abstract: user guide OMRON ZFX-C-CDAPPENDIX

Detailed instructions for use are in the User's Guide.

[. . . ] When the [AUTO] button is pressed, the barcode is read and the result is registered as the master data. Manual setting: Text string up to 32 characters long can be registered as master data via the software keyboard. 2-byte characters, 1-byte kana characters and control codes cannot be entered. The following characters can be used as wildcards: *: Wildcard for zero or more characters ?: Wildcard for one character Master data ASCII code table p. 3 Rename First meas. [. . . ] Other character codes (including control codes) that are read are displayed as spaces. When more than 32 characters are read, "···" is displayed at the end of the string. 6 ZFX-C1_/C2_-CD Additional Functions Instructions 2D Codes This function reads and verifies 2D codes. Measurement items to be executed from this measurement item onwards can also be specified according to the verification results. This allows you to specify a measurement flow matched to the code type. Data Matrix(EC200), QR Code, MicroQR Code, PDF417, MicroPDF417, Maxi Code, AZtec Code, Codablock Setup Draw the measurement region, then execute AUTO setting. The code type and some of the decode conditions are automatically set. When the measurement region contains multiple 2D codes, the result of the first 2D code to be read is output. Measurement region Important Reading will end in error if the 2D Code type is incorrectly set. When AUTO setting is executed, the captured 2D barcode is read, and the following items can be set: ·Code type p. 11 ·Mirror p. 11 ·Code color (for Data Matrix and PDF417 only) p. 11 ·Shape (for Data Matrix only) p. 11 Region settings This function sets the measurement region. MENU mode - [Setup] - [Item] - [Region] Item Measurement region Description Sets the region to be measured. ZFX-C1_/C2_-CD Additional Functions Instructions 7 Registering the master data for verification Master data are used for verification. After reading process, the read text string can be verified against the preregistered master data. Also, processing to be executed from this measurement item onwards can also be branched according to the verification results when measurement control function is ON. MENU mode - [Setup] - [Item] - [Master data] Item Masterdata Description There are two modes for registering master data, auto setting and manual setting. When [Partial verification] is set to ON ON, set the first and last compared digit positions. Up to 32 1 to 1024 (default value first characters can be set as the number of digits. digit:1 last digit:1) Example: First compared digit 2, last compared digit 6 OM R O N 2 0 0 8 2nd digit Output characters OFF (default value) ON Error string Max. 20 digits (default value: NG) OFF (default value) ON Output digit Measurement control 1 to 1024 (default value first digit:1 last digit:1) OFF (default value) ON · Output function of the read results p. 5 ·Measurement control function p. 5 6th digit The text string used for verification becomes "MRON2". Sets whether or not to output the read results on the serial interface. Sets the text string to be output when a read error occurs. ASCII code table p. 3 Sets whether or not to specify a range in the read data to output from when [Output characters] is set to ON. If the read text string contains non-targeted digits, the error string is output. Sets whether or not to control the next measurement item to be executed based on the verification results. Partial output 10 ZFX-C1_/C2_-CD Additional Functions Instructions Decode condition detailed settings Be Sure to set the detailed conditions for the code type. By AUTO setting, Code type, Mirror, Code color, Shape (Data Matrix) are set automatically. MENU mode - [Setup] - [Item] - [Detail]- [Decode condition] Setup Item Code type Setting Value Data Matrix (EC200) QR Code MicroQR Code PDF417 MicroPDF417 Maxi Code AZtec Code Codablock Description Selects the type of 2D Code to be read. Timeout 1 to 9999 ms (default value: 9999) Normal (default value) Reverse Sets the timeout time in read processing. A read error occurs if measurement does not end after the preset timeout time is exceeded. Sets normal or reverse as the image orientation. Mirror Code color Black White Black & White (default value) Specifies the code color. This item is enabled only when the following barcode types are selected: Data Matrix, PDF417 Specifies the code shape. [. . . ] Verified master data Partial verification Last compared digit First compared digit Output characters Error string Partial output Last output digit First output digit Measurement control Code type Range 0: OFF, 1: ON 0: All master data, 1: Master0, 2: Master1, 3: Master2, . . . 32: Master31 0: OFF, 1: ON 1 to 1024 1 to 1024 0: OFF, 1: ON 1 to 20 characters 0: OFF, 1: ON 1 to 1024 1 to 1024 0: OFF, 1: ON 0: JAN/EAN/UPC 1: Code39 2: Codabar 3: ITF 4: Code93 5: Code128/GS1-128 6: GS1 DataBar 7: Pharmacode 1 to 9999 0: OFF, 1: ON 0: OFF, 1: ON 0: Horizontal mode, 1: Vertical mode 0: OFF, 1: ON 1 to 1024 1 to 1024 1 to 32 characters 1 to 10 characters (excluding NULL) 1 to 32 characters 1 to 127 (ZFX-C1_-CD: 1 to 31) 1 to 127 (ZFX-C1_-CD: 1 to 31) 65 66 67 68 69 71 72 74 155+N 187+N 219+N 251+N Timeout time (ms) Check digit Composite component Direction (Pharma) Reverse decode (Pharma) Num. of characters lower limit value Characters threshold Master data for master data N Verified master data for master data N First meas. for master data N ZFX-C1_/C2_-CD Additional Functions Instructions 17 2D Codes Data No. 52 53 54 55 56 57 59 60 61 62 63 64 Parameter Verification func. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE OMRON ZFX-C-CD




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual OMRON ZFX-C-CD will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.