User manual OMRON WD30-SE

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual OMRON WD30-SE. We hope that this OMRON WD30-SE user guide will be useful to you.


OMRON WD30-SE : Download the complete user guide (3042 Ko)

You may also download the following manuals related to this product:

   OMRON WD30-SE (1980 ko)

Manual abstract: user guide OMRON WD30-SE

Detailed instructions for use are in the User's Guide.

[. . . ] M071-E1-01A WD30-ME/-SE/-ME01/-SE01 DeviceNet Wireless Units OPERATION MANUAL Notice (1) This manual may not be copied, reproduced, or reprinted, in whole or in part, without permission. (2) The specifications listed within this manual may be revised without prior notice. However, if you should find any errors or inconsistencies, please contact the OMRON business office. Be sure to tell us the revision number of the manual in which you found the error. Copyrights and Trademarks DeviceNet is a registered trademark of the OpenDeviceNet Vendor Association (ODVA). [. . . ] · The purpose of each test is as follows. Test Installation test Content/Purpose Adjusts the installation position (confirmation of receiving wave, etc. ) and the setup conditions (selection of available frequencies). Both master and slave stations require the switch Checks the wireless communication status with each slave station in a system in operation. This is a switch operation from the master station. Test timing At installation At advance on-site test Confirmation test At confirmation after installation At maintenance and inspection Wireless channel monitor Obtains the receiving wave level of the frequency band (all At installation channels) to allow for the selection of the available channels At advance on-site test (frequency band). 72 Installation Test Section 5-2 5-2 Installation Test This test is for adjusting the installation position (confirmation of receiving wave, etc. ) and the setup conditions (selection of unused frequencies, selection of transmission output, etc. ) at installation. Both master and slave stations require the switch operation. 5-2-1 Preparation · The DeviceNet master and DeviceNet slave do not need to be connected for the installation test. · Set the WNODE switch of the wireless master station to "00" and the WNODE switch of a wireless slave station to "01" to "64", avoiding duplication. · Since both the wireless master stations and wireless slave stations require the transmission power supply, connect them to the power supply via the DeviceNet cable prepared for a micro-connector. 5-2-2 Test procedure Master station W NODE 901 901 X10 X1 901 SW2 RUN TEST SET 78 W CH 901 X10 X1 SW3 ON 12345678 1. Set the mode select switch of the wireless master station to "TEST", and the WNODE switch to the WNODE number of the wireless slave station to be tested. Set SW3 to "bit 4 = ON". 78 78 78 456 23 23 23 Slave station W NODE 901 901 78 78 X10 SW2 RUN TEST SET 78 W CH 901 78 X10 SW3 ON 12345678 Master station MS NS WS Slave station MS NS WS N NODE 901 901 78 23 SW2 RUN TEST SET N NODE 901 901 78 23 SW2 RUN TEST SET 78 78 X10 X1 SW1 ON 1234 X10 X1 SW1 ON 1234 Master station MS NS WS Slave station MS NS WS N NODE 901 901 78 23 SW2 RUN TEST SET N NODE 901 901 78 23 SW2 RUN TEST SET 78 78 X10 X1 X10 X1 SW1 ON 1234 SW1 ON 1234 456 456 456 456 456 456 23 456 23 23 456 456 2. Set the mode select switch of the wireless slave station to "TEST". X1 901 X1 23 23 3. Turn on the communication power supplies of the wireless master station and all wireless slave stations. The system is in test operation status. 23 23 23 456 23 456 456 456 456 456 4. The LED display shows the receiving wave level "L1 to L9", if the wireless master station and the wireless slave station to be tested have been installed within the distance where both stations can receive the electric wave from each other. 73 Installation Test Section 5-2 If the WS LED lights green, this means that the wireless communication link has been established. If the electric wave is weak, adjust the position of the wireless slave station so that receiving wave level is stabilized in L5 or higher. Master station MS Slave station WS MS NS WS NS The LED display shows the receiving wave level "L0" if the devices have been installed N NODE 901 901 78 23 SW2 RUN TEST SET N NODE 901 901 78 23 SW2 RUN TEST SET 78 78 outside the distance where they cannot receive the electric wave from each other. Set the WNODE switch of the wireless master station to the WNODE number ("00" for this example) of the wireless slave station to be tested next, and then press SW2. Repeat this procedure till the communication with all wireless slave stations is established and stabilized. 23 ON 23 X10 X1 X10 SW1 1234 SW1 ON 1234 Master station W NODE 901 901 78 78 78 456 X10 SW2 RUN TEST SET 78 X10 SW3 ON 12345678 74 456 456 456 456 456 456 456 X1 W CH 901 23 23 X1 901 X1 23 23 Confirmation Test Section 5-3 5-3 Confirmation Test This test is for checking the wireless communication status with each slave station in the system in operation after installation. The test can be implemented by the switching operation from the master station. 5-3-1 Preparation · The DeviceNet master does not need to be connected for the confirmation test. (The DeviceNet slave needs to be connected. ) · The confirmation test is employed for the inspection work after installation. · Leave the mode select switches of the wireless slave stations in the "Run" position. 5-3-2 Test procedure Master station W NODE 901 901 X10 X1 901 SW2 RUN TEST SET 78 W CH 901 X10 X1 SW3 ON 12345678 1. Set the mode select switch of the wireless master station to "TEST", and the WNODE switch to the WNODE number of the wireless slave station to be tested. Set SW3 to "bit 5 = ON". 78 78 78 456 23 23 23 Master station MS NS WS N NODE 901 901 78 23 X10 X1 SW1 ON 1234 RUN TEST SET 78 Master station MS NS WS N NODE 901 901 78 23 X10 X1 SW1 ON 1234 RUN TEST SET 78 456 456 23 456 23 23 SW2 2. Turn on the communication power supply to the wireless master station. The NS LED goes off and the MS LED flashes green. 456 456 456 456 SW2 3. [. . . ] !Caution To prevent electric shock when replacing a unit, be sure to turn OFF the power supplies to all of the nodes (master and slaves) before removing the faulty unit. 153 Appendix A Device Profiles Refer to the specifications and device profile in this manual when connecting an OMRON DeviceNet wireless master station to another company's master. Device profile of DeviceNet wireless unit master station (WD30ME/-ME01) General data Applicable DeviceNet Specifi- Volume I-Release 2. 0 cations Volume II-Release 2. 0 Vender name OMRON Corporation Device profile Product catalog number Product revision Physical conformance data Network current consumption Connector type Physical insulation Supported indicator Slaves : Communication Adapter Manual number 1. 0 Open plug Yes Module Network Wireless Rotary switch 0 DIP switch Vender ID = 47 Device profile = 12 MAC ID setting Default MAC ID Transmission communication speed setting Supported transmission communication speeds Communications data 125 kbps 250 kbps 500 kbps Predefined Master/Slave con- Group 2 only server nection set Dynamic connection support No (UCMM) Explicit message fragmentation support Yes 155 Device Profiles Appendix A Object Loading Identity Object (0 x 01) Object class Attribute Service Attribute Not supported Not supported ID content 1 Vendor 2 Product type 3 Product code 4 Revision 5 Status (bits supported) 6 Serial number 7 Product name 8 State Service DeviceNet service 05 Reset OE Get_Attribute_Single Get Set Value 47 12 505 3. 02 Unique for each unit Bit 0 only WD30-ME-V1 Object instance Parameter option No No Message Router Object (0 x 02) Object class Object instance Vender fix specification addition Attribute Service Attribute Service Not supported Not supported Not supported Not supported No DeviceNet Object (0 x 03) Object class Attribute Service Attribute Not supported Not supported ID content 1 MAC ID 2 Communication speed 3 BOI 4 Bus-off counter 5 Allocation Information 6 MAC ID switch changed 7 Communication speed switch changed 8 MAC ID switch value 9 Communication speed switch Service DeviceNet service 0E Get_Attribute_Single 4B Allocate Master/ Slave_Connection_Set Release_Master/ Slave_Connection_Set Get Set Value Object instance 00H Parameter option No No No 156 Device Profiles Connection Object (0 x 05) Object class Attribute Service Max. number of active connections Object instance 1 Section Instance type Production trigger Transport type Transport class Attribute Not supported Not supported 1 Appendix A Information Explicit Message Cyclic Server 3 ID content 1 State 2 Instance type 3 Transport class trigger 4 Produced connection ID Max. number of instances 1 Get Set Value 0000H 8300H 5 Consumed connection ID 6 Initial comm. characteristics 7 Produced connection size 8 Consumed connection size 9 Expected packet rate 12 Watchdog time-out action 13 Produced connection path length 14 Produced connection path 15 Consumed connection path length 16 Consumed connection path Service DeviceNet service 05 Reset 0E Get_Attribute_Single 10 Set_Attribute_Single 2100H FF00H FF00H 0100H 0000H 0000H Parameter option No No No 157 Device Profiles Object instance 2 Section Instance type Production trigger Transport type Transport class Attribute Information Polled I/O Cyclic Server 2 ID content 1 State 2 Instance type 3 Transport class trigger 4 Produced connection ID Get Set Appendix A Max. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE OMRON WD30-SE




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual OMRON WD30-SE will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.