User manual OMRON V680-CA5D02-V2

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual OMRON V680-CA5D02-V2. We hope that this OMRON V680-CA5D02-V2 user guide will be useful to you.


OMRON V680-CA5D02-V2 : Download the complete user guide (6185 Ko)

Manual abstract: user guide OMRON V680-CA5D02-V2

Detailed instructions for use are in the User's Guide.

[. . . ] No. Z249-E1-04 RFID System V680 Series ID Controller USER´S MANUAL RFID System V680 Series User's Manual ID Controller V680-CA5D01-V2 V680-CA5D02-V2 Cat. Z249-E1-04 Introduction Thank you for purchasing a V680-series RFID System. This manual describes the functions, performance, and application methods needed for optimum use of the V680-series RFID System. · Allow the RFID System to be installed and operated only by qualified specialist with a sufficient knowledge of electrical systems. [. . . ] 0 or 16 × × Write area start address × × 4 × × × × Write data . . . n × × Terminator * 2 CR Communications designation Specifies the method of communications with the Tag. Refer to Communications Designation Function for details on the communications designation. "A": ASCII "H": Hexadecimal Specifies the Antenna with which to communicate. "1": Antenna 1 "2": Antenna 2 A unique identifier used to identify Tags. Specifies the start address of the area in the Tag from which data is to be read from in 4-digit hexadecimal. Setting range: 0000H to FFFAH Specifies the number of bytes to read from the Tag in 4-digit hexadecimal. Setting range: 0001H to FFFAH · ASCII: 510 bytes (510 characters) · Hexadecimal: 510 bytes (1020 characters) Data designation SECTION 5 V680 Commands Antenna designation UID Read area start address No. of bytes to read Response Communications Designation Other Than PA or PI Antenna Resend flag desigCommand End code nation code Q 2 W 0 2 0 × 1 0 1 × × UID . . . 0 or 16 × × Terminator * 2 CR Note: When using the multi-access trigger communications designation (MT), the ID controller returns an end code of 03 after communicating with all Tags. Communications Designation of PA or PI Antenna Resend flag Command desigcode End code nation Q 2 W 0 2 1 × 1 0 1 × × UID . . . 0 or 16 × × Terminator * 2 CR UID A unique identifier used to identify Tags. In the case of multi-access communications designations (MT/MR), the UID of the Tag that is being written to is added to the data. 138 RFID System User's Manual SECTION 5 Communications 1:N Protocol Command Communi- Data Command cations desigdesignation nation code × 2 Q 2 W × 2 × A/H 1 Antenna designation UID 1/2 1 × × . . . 0 or 16 × × × Read area start address × 4 × × × × Write data . . . n × × × 2 FCS × Terminator * 2 CR Controller No. @ 1 0 1 × Communications designation Specifies the method of communications with the Tag. Refer to Communications Designation Function for details on the communications designation. "A": ASCII "H": Hexadecimal Specifies the Antenna with which to communicate. "1": Antenna 1 "2": Antenna 2 A unique identifier used to identify Tags. Specifies the start address of the area in the Tag from which data is to be read from in 4-digit hexadecimal. Setting range: 0000H to FFFAH Specifies the number of bytes to read from the Tag in 4-digit hexadecimal. Setting range: 0001H to FFFAH · ASCII: 510 bytes (510 characters) · Hexadecimal: 510 bytes (1, 020 characters) Data designation Antenna designation UID Read area start address SECTION 5 V680 Commands No. [. . . ] / TC1(SOH) DC1 TC2(STX) DC2 TC3(ETX) DC3 TC4(EOT) DC4 TC5(NEQ) TC8(NAK) TC6(ACK) TC9(SYN) BEL FE0(BS) FE1(HT) FE2(LF) FE3(VT) FE4(FF) FE5(CR) SO SI TC10(ETB) CAN EM SUB ESC IS4(FS) IS3(GS) IS2(RS) IS1(US) Note 1. Do not use undefined areas. SECTION 7 ASCII Table RFID System User's Manual 267 SECTION 7 Appendices Degree of Protection Ingress protection degrees (IP-Be sure to check the sealing capability under the actual operating environment and conditions before actual use. IP indicates the ingress protection symbol. IEC (International Electrotechnical Commission) Standards IEC 60529: 1989-11 (A) First Digit: Degree of Protection from Solid Materials Degree 0 50 mm dia. Degree No protection Protects against penetration of any solid object such as a hand that is 50 mm or more in diameter. 1 Protects against penetration of any solid object, such as a finger, that is 12. 5 mm or more in diameter. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE OMRON V680-CA5D02-V2




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual OMRON V680-CA5D02-V2 will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.