Detailed instructions for use are in the User's Guide.
[. . . ] SIEC71060620-01-OY
V1000
Compact Vector Control Drive Model: VZA 200 V Class Three-Phase Input 0. 1 to 15 kW 200 V Class Single-Phase Input 0. 1 to 4. 0 kW 400 V Class Three-Phase Input 0. 2 to 15 kW
USER'S MANUAL
OYMC AC Drive - V1000
Compact Vector Control Drive
User Manual
Type: VZA Model: 200 V Class, Single-Phase Input: 0. 1 to 4. 0 kW 200 V Class, Three-Phase Input: 0. 1 to 15. 0 kW 400 V Class, Three-Phase Input: 0. 2 to 15. 0 kW
To properly use the product, read this manual thoroughly and retain for easy reference, inspection, and maintenance. Ensure the end user receives this manual.
Receiving
1 2 3 4 5 6 7 8 A B C D
Mechanical Installation
Electrical Installation Start-Up Programming & Operation Parameter Details
Troubleshooting Periodic Inspection & Maintenance Peripheral Devices & Options Specifications
Parameter List MEMOBUS/Modbus Communications
MANUAL NO. SIEP C710606 20
Standards Compliance
This Page Intentionally Blank
Copyright © 2008 OMRON YASKAWA MOTION CONTROL B. V. No part of this publication may be reproduced, stored in a retrieval system, or transmitted, in any form or by any means, mechanical, electronic, photocopying, recording, or otherwise, without the prior written permission of OYMC. [. . . ] YES The CHARGE indicator light is broken or · Replace the drive. YES disconnected.
246
SIEP C710606 20 OYMC AC Drive - V1000 User Manual
6. 6 Operator Programming Errors
6. 6
Operator Programming Errors
An Operator Programming Error (oPE) occurs when an inappropriate parameter is set or an individual parameter setting is inappropriate. The drive will not operate until the parameter is set correctly; however, no alarm or fault outputs will occur. If an oPE occurs, investigate the cause and Refer to oPE Codes, Causes, and Possible Solutions on page 247 for the appropriate action. When an oPE error is displayed, press the ENTER button to display U1-18 (oPE fault constant). This monitor displays the parameter causing the oPE error.
u oPE Codes, Causes, and Possible Solutions
Table 6. 11 oPE Codes, Causes, and Possible Solutions LED Operator Display Error Name Drive Capacity Setting Fault oPE01 Drive capacity and the value set to o2-04 do not match. Cause Possible Solutions The drive capacity setting (o2-04) and the actual capacity of the drive are Correct the value set to o2-04. LED Operator Display Error Name Parameter Range Setting Error oPE02 Use U1-18 to find parameters set outside the range. Cause Possible Solutions Parameters were set outside the possible setting range. Note: Other errors are given precedence over oPE02 when multiple errors occur at the same time. LED Operator Display Error Name Multi-Function Input Selection Error oPE03 A contradictory setting is assigned to multi-function contact inputs H1-01 to H1-06. Cause Possible Solutions · The same function is assigned to two multi-function inputs. · Ensure all multi-function inputs are assigned to different functions. · Excludes "Not used" and "External Fault. " · Re-enter the multi-function settings to ensure this does not occur. The Up command was set but the Down command was not, or vice versa (settings 10 vs. Correctly set functions that need to be enabled in combination with other The Up 2 command was set but the Down 2 command was not, or vice functions. · Run/Stop command for a 2-Wire sequence was set (H1- = 42), but Correctly set functions that need to be enabled in combination with other forward/reverse command (H1- = 43) was not. · "Drive Enable" is set to multi-function input S1 or S2 (H1-01 = 6A or functions. Two of the following functions are set at the same time: · Up/Down Command (10 vs. 11) · Check if contradictory settings have been assigned to the multi-function · Up 2/Down 2 Command (75 vs. · Analog Frequency Reference Sample/Hold (1E) · Offset Frequency 1, 2, 3 Calculations (44, 45, 46) The Up/Down command (10, 11) is enabled at the same time as PID control Disable control PID (b5-01 = "0") or disable the Up/Down command. Settings for NC and NO input for the following functions were selected at the same time: · External Search Command 1 and External Search Command 2 (61 vs. [. . . ] 228, 239 Uv2 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 228, 239 Uv3 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 228, 240 V/f Pattern Defaults . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 339 V/f Pattern Selection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . [. . . ]