User manual OMRON NE1A-SCPU01 07-2009

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual OMRON NE1A-SCPU01. We hope that this OMRON NE1A-SCPU01 user guide will be useful to you.


OMRON NE1A-SCPU01 07-2009: Download the complete user guide (6507 Ko)

You may also download the following manuals related to this product:

   OMRON NE1A-SCPU01 2005 (4787 ko)
   OMRON NE1A-SCPU01 2006 (5042 ko)
   OMRON NE1A-SCPU01 2006 (6069 ko)
   OMRON NE1A-SCPU01 2006 (3640 ko)
   OMRON NE1A-SCPU01 2006 (3681 ko)
   OMRON NE1A-SCPU01 2006 (3637 ko)
   OMRON NE1A-SCPU01 2006 (3815 ko)
   OMRON NE1A-SCPU01 2009 (6500 ko)
   OMRON NE1A-SCPU01 04-2005 (2655 ko)
   OMRON NE1A-SCPU01 09-2006 (6236 ko)
   OMRON NE1A-SCPU01 2006 (6083 ko)

Manual abstract: user guide OMRON NE1A-SCPU0107-2009

Detailed instructions for use are in the User's Guide.

[. . . ] Z906-E1-07 DeviceNet Safety NE1A Series: NE1A-SCPU01(-V1)(-EIP)/ -SCPU02(-EIP) Safety Network Controller OPERATION MANUAL NE1A Series Safety Network Controller: NE1A-SCPU01(-V1)(-EIP)/-SCPU02(-EIP) Operation Manual Revised July 2009 iv Notice: OMRON products are manufactured for use according to proper procedures by a qualified operator and only for the purposes described in this manual. The following conventions are used to indicate and classify precautions in this manual. Failure to heed precautions can result in injury to people or damage to property. !WARNING Indicates a potentially hazardous situation which, if not avoided, will result in minor or moderate injury, or may result in serious injury or death. Additionally, there may be significant property damage. Indicates general prohibitions for which there is no specific symbol. Indicates general mandatory actions for which there is no specific symbol. OMRON Product References All OMRON products are capitalized in this manual. [. . . ] Up to eight input conditions can be evaluated. Optional Input Settings The number of inputs can be increased on the In/Out Setting Tab Page in the function block property dialog box. Parameter Number of inputs Setting range 1 to 8 Default setting 2 143 Command Reference: Logic Functions Truth Tables Truth Table for One-input AND Evaluation Input 1 0 1 Output 1 0 1 Section 8-4 0: OFF, 1: ON Truth Table for Two-input AND Evaluation Input 1 0 x 1 Input 2 x 0 1 Output 1 0 0 1 0: OFF, 1: ON, x: Either ON or OFF Truth Table for Three-input AND Evaluation Input 1 0 x x 1 Input 2 x 0 x 1 Input 3 x x 0 1 Output 1 0 0 0 1 0: OFF, 1: ON, x: Either ON or OFF Truth Table for Four-input AND Evaluation Input 1 0 x x x 1 Input 2 x 0 x x 1 Input 3 x x 0 x 1 Input 4 x x x 0 1 Output 1 0 0 0 0 1 0: OFF, 1: ON, x: Either ON or OFF Truth Table for Five-input AND Evaluation Input 1 0 x x x x 1 Input 2 x 0 x x x 1 Input 3 x x 0 x x 1 Input 4 x x x 0 x 1 Input 5 x x x x 0 1 Output 1 0 0 0 0 0 1 0: OFF, 1: ON, x: Either ON or OFF 144 Command Reference: Logic Functions Truth Table for Six-input AND Evaluation Input 1 0 x x x x x 1 Input 2 x 0 x x x x 1 Input 3 x x 0 x x x 1 Input 4 x x x 0 x x 1 Input 5 x x x x 0 x 1 Input 6 x x x x x 0 1 Section 8-4 Output 1 0 0 0 0 0 0 1 0: OFF, 1: ON, x: Either ON or OFF Truth Table for Seven-input AND Evaluation Input 1 0 x x x x x x 1 Input 2 x 0 x x x x x 1 Input 3 x x 0 x x x x 1 Input 4 x x x 0 x x x 1 Input 5 x x x x 0 x x 1 Input 6 x x x x x 0 x 1 Input 7 x x x x x x 0 1 Output 1 0 0 0 0 0 0 0 1 0: OFF, 1: ON, x: Either ON or OFF Truth Table for Eight-input AND Evaluation Input 1 0 x x x x x x x 1 Input 2 x 0 x x x x x x 1 Input 3 x x 0 x x x x x 1 Input 4 x x x 0 x x x x 1 Input 5 x x x x 0 x x x 1 Input 6 x x x x x 0 x x 1 Input 7 x x x x x x 0 x 1 Input 8 x x x x x x x 0 1 Output 1 0 0 0 0 0 0 0 0 1 0: OFF, 1: ON, x: Either ON or OFF 145 Command Reference: Logic Functions Section 8-4 8-4-3 Diagram OR Default Maximum Number of Inputs General Description An OR of the input conditions will be output. Up to eight input conditions can be evaluated. Optional Input Setting The number of inputs can be increased on In/Out Setting Tab Page in the function block property dialog box. Parameter Number of inputs Setting range 1 to 8 Default setting 2 Truth Table Truth Table for One-input OR Evaluation Input 1 0 1 Output 1 0 1 0: OFF, 1: ON Truth Table for Two-input OR Evaluation Input 1 0 1 x Input 2 0 x 1 Output 1 0 1 1 0: OFF, 1: ON, x: Either ON or OFF 146 Command Reference: Logic Functions Truth Table for Three-input OR Evaluation Input 1 0 1 x x Input 2 0 x 1 x Input 3 0 x x 1 Output 1 0 1 1 1 Section 8-4 0: OFF, 1: ON, x: Either ON or OFF Truth Table for Four-input OR Evaluation Input 1 0 1 x x x Input 2 0 x 1 x x Input 3 0 x x 1 x Input 4 0 x x x 1 Output 1 0 1 1 1 1 0: OFF, 1: ON, x: Either ON or OFF Truth Table for Five-input OR Evaluation Input 1 0 1 x x x x Input 2 0 x 1 x x x Input 3 0 x x 1 x x Input 4 0 x x x 1 x Input 5 0 x x x x 1 Output 1 0 1 1 1 1 1 0: OFF, 1: ON, x: Either ON or OFF Truth Table for Six-input OR Evaluation Input 1 0 1 x x x x x Input 2 0 x 1 x x x x Input 3 0 x x 1 x x x Input 4 0 x x x 1 x x Input 5 0 x x x x 1 x Input 6 0 x x x x x 1 Output 1 0 1 1 1 1 1 1 0: OFF, 1: ON, x: Either ON or OFF 147 Command Reference: Logic Functions Truth Table for Seven-input OR Evaluation Input 1 0 1 x x x x x x Input 2 0 x 1 x x x x x Input 3 0 x x 1 x x x x Input 4 0 x x x 1 x x x Input 5 0 x x x x 1 x x Input 6 0 x x x x x 1 x Section 8-4 Input 7 0 x x x x x x 1 Output 1 0 1 1 1 1 1 1 1 0: OFF, 1: ON, x: Either ON or OFF Truth Table for Eight-input OR Evaluation Input 1 0 1 x x x x x x x Input 2 0 x 1 x x x x x x Input 3 0 x x 1 x x x x x Input 4 0 x x x 1 x x x x Input 5 0 x x x x 1 x x x Input 6 0 x x x x x 1 x x Input 7 0 x x x x x x 1 x Input 8 0 x x x x x x x 1 Output 1 0 1 1 1 1 1 1 1 1 0: OFF, 1: ON, x: Either ON or OFF 8-4-4 Diagram Exclusive OR (EXOR) General Description An exclusive OR of the input conditions will be output. 148 Command Reference: Logic Functions Truth Table Truth Table for Exclusive OR Evaluation Input 1 0 0 1 1 Input 2 0 1 0 1 Output 1 0 1 1 0 Section 8-4 0: OFF, 1: ON 8-4-5 Diagram Exclusive NOR (EXNOR) General Description An exclusive NOR of the input conditions will be output. Truth Table Truth Table for Exclusive NOR Evaluation Input 1 0 0 1 1 Input 2 0 1 0 1 Output 1 1 0 0 1 0: OFF, 1: ON 8-4-6 Diagram Reset Set Flip-Flop (RS-FF) Unit Ver. 1. 0 or Later Input RESET Output Enable Input RESET Output Enable Fault Present Default Maximum Number of I/O 149 Command Reference: Logic Functions General Description Section 8-4 This function can be used with Controllers with unit version 1. 0 or later (including Controllers that support EtherNet/IP). When the input condition to the Reset Set Flip-Flop function block is turned ON, that ON status is maintained (latched) in the function block and the ON output is maintained at the Output Enable signal. The ON status is maintained in the function block, so the Output Enable signal stays ON even if the input condition goes from ON to OFF. The signal maintained in the function block is turned OFF when the function block's RESET condition is turned ON. Fault Present Output Setting A Fault Present output can also be used in programming. To enable this output, select the Fault Present checkbox on the Out Point Tab Page of the function block properties dialog box. Error Handling and Error Resetting Error condition Input and Reset are active simultaneously. Behavior for error detection Output Enable Fault Present OFF ON (safety state) Resetting the error condition Make one of the signals inactive. Timing Table Input RESET Output Enable Fault Present 150 Command Reference: Logic Functions Section 8-4 8-4-7 Diagram Comparator Unit Ver. 1. 0 or Later Input1 Output Enable Input1 Input2 Input3 Input4 Input5 Input6 Input7 Input8 Output Enable Default Maximum Number of Inputs General Description This function can be used with unit version 1. 0 or later (including Controllers that support EtherNet/IP). The Comparator function block compares the specified input signals (up to 8 inputs) with the comparison data set in the Configurator, and turns ON the Output Enable signal when all of the input signals match the comparison data. The Output Enable signal will be turned OFF when the input signals no longer match the comparison data. From 1 to 8 inputs can be set for the input signals. Set Parameters Parameter Comparison Data Setting range Default setting 00000000 to 11111111 00000001 (Input 1 is ON. ) (Individual bits correspond to Input 1 to Input 8) Optional Input Settings The number of inputs can be increased on the In/Out Setting Tab Page in the function block property dialog box. Parameter Number of inputs Setting range 1 to 8 Default setting 1 151 Command Reference: Logic Functions Truth Table Section 8-4 Truth Table for Comparator Evaluation (CD = Comparison Data): Input signals to Comparator Output signals from Comparator Input 7 × Input 8 × Output Enable 0 Input 1 CD for Input 1 × Input 2 × Input 3 × Input 4 × Input 5 × Input 6 × CD for Input 2 × × × × × × × 0 × CD for Input 3 × × × × × × 0 × × × × × CD for Input 4 × × × × × 0 CD for Input 5 × × × × 0 × × × × × × × × × CD for Input 6 × × × 0 CD for Input 7 × × 0 × × × × × × = CD for Input 1 = CD for Input 2 = CD for Input 3 = CD for Input 4 = CD for Input 5 = CD for Input 6 = CD for Input 7 CD for Input 8 = CD for Input 8 0 1 0: OFF; 1: ON Note "= CD for Input n" indicates that the Comparator input signals are the same as the comparison data. " CD for Input n" indicates that the Comparator input signals are not the same as the comparison data. "×" indicates that the status is not applicable (the input signals and comparison data may or may not be the same). 152 Command Reference: Logic Functions Timing Chart Section 8-4 Output Enable 1 2 The horizontal broken lines in the above diagram represent the comparison data for each input. Output Enable turns ON when all of the input signals match the comparison data. Output Enable turns OFF when any of the input signals does not match the comparison data. 153 Command Reference: Function Blocks Section 8-5 8-5 8-5-1 Command Reference: Function Blocks Reset Diagram Reset Monitored Input Output Enable Default Maximum Number of Inputs General Description The Output Enable signal will turn ON if the Reset signal is correctly input while the input condition to the Reset function block is ON. This function block can be used to prevent the machine from automatically reset, e. g. , when the power to the NE1A-series Controller is turned ON, when the operating mode is changed (from IDLE Mode to RUN Mode), or when a signal from a safety input device turns ON. Conditions for Output Enable Turning ON · The Monitored Input and all enabled optional inputs must be ON. Conditions for Static Release Turning ON The Monitored Input and all enabled optional inputs must be ON. Conditions for Reset Required Indication Turning ON If the following condition is met, the Reset Required Indication will become a 1-Hz pulse output. · The Monitored Input and all enabled optional inputs must be ON. If the Reset Signal is set to Low-High-Low, the Reset Required Indication will turn ON when the next condition is met. [. . . ] With a single-cast connection, a Safety Master and Safety Slave communications 1:1. This connection can be set for either an input or an output, and separate connections are needed for each. In this manual, items used for general control purposes are called "standard" to differentiate them from devices, functions, data, and other items for which which safety measures have been applied. A CPU Unit used for standard control, such as CPU Units in OMRON's CS or CJ Series. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE OMRON NE1A-SCPU01




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual OMRON NE1A-SCPU01 will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.