User manual OMRON N

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual OMRON N. We hope that this OMRON N user guide will be useful to you.


OMRON N : Download the complete user guide (3440 Ko)

You may also download the following manuals related to this product:

   OMRON N (4665 ko)
   OMRON N (4862 ko)

Manual abstract: user guide OMRON N

Detailed instructions for use are in the User's Guide.

[. . . ] Z197-E1-02A ZX-L-N Series Smart Sensors Laser Type USER'S MANUAL ÇÕǹÇ?Ç Section 1 Section 2 Section 3 Section 4 Section 5 Section 6 Section 7 Introduction ëÊ 1 èÕ ëÊ 2 èÕ ëÊ 3 èÕ ëÊ 4 èÕ Introduction APPLICATION CONSIDERATIONS (Please Read) Section 1 FEATURES Section 2 PREPARATION FOR MEASUREMENT Section 3 BASIC OPERATION Section 4 MAIN APPLICATIONS AND SETTING METHODS Section 5 DETAILED SETTINGS Section 6 AUXILIARY FUNCTIONS Section 7 APPENDIX User's Manual Smart Sensors ZX-L-N Series Introduction Introduction Introduction Introduction Thank you for purchasing the ZX-L-N Series Smart Sensor. This manual provides information regarding functions, performance and operating methods that are required for using the sensor. When using the ZX-L-N Smart Sensor, make sure to observe the following: · The ZX-L-N Smart Sensor must be operated by personnel knowledgeable in electrical engineering. · To ensure correct use, please read this manual thoroughly to deepen your understanding of the product. [. . . ] Automatic teaching is useful when you want to set threshold values by starting the device and obtaining real measurements. Position teaching Two-point teaching Automatic teaching Hysteresis (hysteresis width) can also be set for threshold values. Set hysteresis when judgements are unstable to prevent chattering. p. 94 88 ZX-L-N User's Manual Section 5 DETAILED SETTINGS Inputting Threshold Values Directly The threshold values can be set by directly inputting the numeric values. Direct input is useful when you know the dimensions for an OK judgement or when you want to fine-tune threshold values after teaching. Moving to T Mode 1. Set the mode switch to T. RUN T FUN Setting Threshold Values 2. Move the threshold switch to either H or L, i. e. , the threshold to be set. The current measured value will be displayed on the main display. The currently set threshold value (either HIGH or LOW, depending on the threshold switch setting) will be displayed on the sub-display. H L LD ON ZERO ENABLE (mm) Section 5 Entering Threshold Values SUB 3. Press any Cursor Key. The leftmost digit of the sub-display will flash. SUB 4. Use the Cursor Keys to set the threshold Moves from one digit to another. Press the ENT Key to confirm the setting. The setting will be registered. SUB Countermeasures for Setting Errors If ERRLH or ERRHL is displayed, the following error has occurred. · HIGH threshold value < LOW threshold value · HIGH threshold value - LOW threshold value < hysteresis width SUB SUB Hysteresis Setting p. 94 If an error is displayed, the threshold values have not been updated. Set the threshold values again. User's Manual ZX-L-N 89 Section 5 DETAILED SETTINGS Position Teaching Performs measurement and uses the measurement results to set threshold values. Position teaching is useful when threshold samples, i. e. , with the upper and lower limits, can be obtained beforehand. Sensor head Sensor head Threshold sample (Upper limit) Teaching point = LOW threshold Threshold sample (Lower limit) Teaching point = HIGH threshold Hold, trigger mode, and scaling settings that have been made before teaching are reflected in the teaching measurements. Section 5 Entering Threshold Values Moving to T Mode 1. Set the mode switch to T. RUN T FUN Setting Threshold Values 2. Move the threshold switch to either H or L, i. e. , the threshold to be set. The current measured value will be displayed on the main display. The currently set threshold value (either HIGH or LOW, depending on the threshold switch setting) will be displayed on the sub-display. LD ON ZERO ENABLE (mm) SUB 3. Place the threshold sample in position. The main display value changes. 4. Press the ENT Key for at least one second and then release. The measured value at the point that the ENT Key is released will be set as the threshold value. This threshold value will be shown on the sub-display. SUB When [ERRLH] or [ERRHL] is displayed p. 89 The threshold values set using position teaching can be changed using direct input. This is useful when setting judgement tolerances for measured values. p. 89 90 ZX-L-N User's Manual Section 5 DETAILED SETTINGS Two-point teaching Performs measurement on two samples and uses the intermediate value of the two measurement results to set threshold values. Two-point teaching is useful when you want to detect subtle differences between the standard sample and defective samples. Sensor head Sensor head Teaching point A Standard sample Defective sample Teaching point B The threshold can be calculated by the following equation. Threshold = (Teaching point A + Teaching point B) / 2 Section 5 Entering Threshold Values Hold, trigger mode, and scaling settings that have been made before teaching are reflected in the teaching measurements. Setting Teaching point A 1. of the position teaching procedure. Setting Threshold Values SUB 2. [. . . ] For other wavelengths the hazard to the unaided eye is no greater than for Class 1. Direct intrabeam viewing of Class 3A lasers with optical aides (e. g. , binoculars, telescopes, microscopes) may be hazardous. Lasers which are also capable of producing hazardous diffuse reflections. Their use requires extreme caution. Class 3A Class 3B Class 4 Note: Conditions for safe viewing of diffuse reflections for Class 3B visible lasers are: minimum viewing distance of 13 cm between screen and cornea and a maximum viewing time of 10 s. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE OMRON N




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual OMRON N will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.