User manual OMRON K8AB-PM

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual OMRON K8AB-PM. We hope that this OMRON K8AB-PM user guide will be useful to you.


OMRON K8AB-PM : Download the complete user guide (278 Ko)

You may also download the following manuals related to this product:

   OMRON K8AB-PM (597 ko)
   OMRON K8AB-PM (652 ko)
   OMRON K8AB-PM (622 ko)
   OMRON K8AB-PM (648 ko)
   OMRON K8AB-PM (733 ko)
   OMRON K8AB-PM (651 ko)
   OMRON K8AB-PM (753 ko)
   OMRON K8AB-PM (176 ko)
   OMRON K8AB-PM (724 ko)
   OMRON K8AB-PM (647 ko)
   OMRON K8AB-PM (679 ko)

Manual abstract: user guide OMRON K8AB-PM

Detailed instructions for use are in the User's Guide.

[. . . ] UL certification pending. Model Number Structure Model Number Legend K8AB-Functions PM: Three-phase Phase-sequence Phase-loss Relay (Simultaneous upper and lower monitoring) 3. Rated Input Voltage 1: 115, 127, 133, 138, 200, 220, 230, 240 VAC 2: 220, 230, 240, 277, 380, 400, 415, 480 VAC Cat. N146-E1-01 Three-phase Phase-sequence Phase-loss Relay K8AB-PM 1 Ordering Information List of Models Three-phase Phase-sequence Phase-loss Relay Rated input (See note 2. ) 3-phase 3-wire mode 200, 220, 230, 240 VAC Model K8AB-PM1 3-phase 4-wire mode 115, 127, 133, 138 VAC 3-phase 3-wire mode 380, 400, 415, 480 VAC K8AB-PM2 3-phase 4-wire mode 220, 230, 240, 277 VAC Note: 1. [. . . ] The indicator flashes to indicate the error status after the overvoltage has exceeded the threshold value while the operating time is being clocked. Red The indicator flashes to indicate the error status after the undervoltage has exceeded the threshold value while the operating time is being clocked. · Lit for phase sequence error. Setting Knobs Item Overvoltage knob (OVER) Undervoltage knob (UNDER) Operating time knob (T) Usage Used to set the voltage to -30% to 25% of the rated input voltage. Used to set the operating time to 0. 1 to 30 s. 4 Three-phase Phase-sequence Phase-loss Relay K8AB-PM Cat. N146-E1-01 Function Selection DIP Switch ON SW1 SW2 SW3 SW4 DIP Switch DIP Switch Functions SW1 SW2 Function Power ON lock time OFF 1s ON 5s Monitoring mode OFF 3-phase 3-wire selector power monitoring mode ON 3-phase 4-wire power monitoring mode SW4 Function 3-phase 3-wire mode OFF ON OFF ON OFF ON OFF ON OFF OFF ON ON OFF OFF ON ON Rated input voltage switch (K8AB-PM2) Rated input voltage switch (K8AB-PM1) 200 VAC 220 VAC 230 VAC 240 VAC 380 VAC 400 VAC 415 VAC 480 VAC 3-phase 4-wire mode 115 VAC 127 VAC 133 VAC 138 VAC 220 VAC 230 VAC 240 VAC 277 VAC OFF OFF OFF OFF Default OFF OFF SW3 Default SW3 SW4 Dimensions K8AB-PM 22. 5 100 5 90 5 Cat. N146-E1-01 Three-phase Phase-sequence Phase-loss Relay K8AB-PM 5 Safety Precautions Precautions for Safe Use Make sure to follow the instructions below to ensure safety. · Outdoors, or places subject to direct sunlight or wearing weather. · Places where dust, iron powder, or corrosive gases (in particular, sulfuric or ammonia gas) exist. Make sure to thoroughly understand all instructions in the Instructions Manual before handling this product. Make sure to confirm terminal makings and polarity for correct wiring. Operating ambient temperature and humidity for this product must be within the indicated rating when using this product. 10. To enable an operator to turn off this product easily, install switches or circuit breakers that conform to relevant requirements of IEC60947-1 and IEC60947-3, and label them appropriately. Precautions for Correct Use For Proper Use 1. Make sure to use setting values appropriate for the controlled object. Failure to do so can cause unintended operation, and may result in accident or corruption of the product. Only use this product within a board whose structure allows no possibility for fire to escape. About Installation 1. (If you do not secure space for heat dissipation, life cycle of the product will be compromised. ) 3. To avoid electrical shocks, make sure that power is not supplied to the product while wiring. To avoid electrical shocks, make sure that power is not supplied to the product when performing DIP switch settings. Noise Countermeasures 1. Do not install the product near devices generating strong high frequency waves or surges. When using a noise filter, check the voltage and current and install it as close to the product as possible. [. . . ] Warranty and Limitations of Liability WARRANTY OMRON's exclusive warranty is that the products are free from defects in materials and workmanship for a period of one year (or other period if specified) from date of sale by OMRON. CHANGE IN SPECIFICATIONS Product specifications and accessories may be changed at any time based on improvements and other reasons. Consult with your OMRON representative at any time to confirm actual specifications of purchased product. DIMENSIONS AND WEIGHTS Dimensions and weights are nominal and are not to be used for manufacturing purposes, even when tolerances are shown. ALL DIMENSIONS SHOWN ARE IN MILLIMETERS. To convert millimeters into inches, multiply by 0. 03937. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE OMRON K8AB-PM




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual OMRON K8AB-PM will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.