User manual OMRON K3MA-L

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual OMRON K3MA-L. We hope that this OMRON K3MA-L user guide will be useful to you.


OMRON K3MA-L : Download the complete user guide (454 Ko)

You may also download the following manuals related to this product:

   OMRON K3MA-L (407 ko)
   OMRON K3MA-L (502 ko)
   OMRON K3MA-L (805 ko)
   OMRON K3MA-L (826 ko)
   OMRON K3MA-L (386 ko)
   OMRON K3MA-L (704 ko)
   OMRON K3MA-L (484 ko)
   OMRON K3MA-L (386 ko)
   OMRON K3MA-L (380 ko)
   OMRON K3MA-L (1073 ko)
   OMRON K3MA-L (409 ko)
   OMRON K3MA-L (423 ko)
   OMRON K3MA-L (856 ko)
   OMRON K3MA-L (446 ko)
   OMRON K3MA-L (870 ko)

Manual abstract: user guide OMRON K3MA-L

Detailed instructions for use are in the User's Guide.

[. . . ] Operating:-10°C to 55°C (with no condensation or icing) Storage:-25°C to 65°C (with no condensation or icing) Operating:25% to 85% (with no condensation) UL3121-1, conforms to EN61010-1 (Pollution degree 2/overvoltage category II) Conforms to VDE0106/P100 (finger protection) (EMI)EN61326+A1Industry Emission Enclosure:CISPR 11 Group 1 class A: CISRP16-1/-2 Emission AC Mains:CISPR 11 Group 1 class A: CISRP16-1/-2 (EMS)EN61326+A1Industry Immunity ESD:EN61000-4-2:4 kV contact discharge 8 kV air discharge Immunity RF-interference:EN61000-4-3:10 V/m (amplitude-modulated, 80 MHz to 1 GHz) Electrical Fast Transient Noise:EN61000-4-4:2 kV (power line) Immunity Burst Noise:1 kV line to line (I/O signal line) Immunity Surge:EN61000-4-5:1 kV (power line) 2 kV line to ground (power line) Immunity Conducted Disturbance:EN61000-4-6:3 V (0. 15 to 80 MHz) Immunity Voltage Dip/Interrupting:EN61000-4-11:0. 5 cycle, 0, 180°, 100% (rated voltage) Approx. 200 g Vibration resistance Shock resistance Ambient temperature Ambient humidity Approved safety standards EMC Weight K-46 Temperature Meter K3MA-L Characteristics Indication accuracy (at 23±5°C) (See note. ) Thermocouple: (±0. 5% of indication value or ±1°C, whichever greater) ±1 digit max. Platinum-resistance thermometer: (±0. 5% of indication value or ±1°C, whichever greater) ±1 digit max. Thermocouple: K, J, T, E, L, U, N, R, S, B Platinum-resistance thermometer: JPt100, Pt100 Double integral method 500 ms Sampling period (sampling times multiplied by number of averaging times if average processing is selected. ) 4 digits (-1999 to 9999) 7-segment digital display, Character height: 14. 2 mm "-" is displayed automatically with a negative input signal. [. . . ] Product failure may prevent comparative outputs from being generated, resulting in serious accidents. Maintain the power supply voltage within the range specified in the specifications. Check each terminal for correct number and polarity before connecting it. Incorrect or reverse connections may damage or burn out internal components in the product. Provide a switch or circuit breaker so that operators can easily turn OFF the power supply when necessary. Do not use the product where flammable or combustible gases are present. Temperature Meter + Signal input Temperature Meter Power supply input - Surge absorber Application General Precautions 1. Do not use the product in the following locations: · Locations subject to direct radiant heat from heating equipment. · Locations subject to dust or corrosive gases (particularly, sulfuric gas or ammonia gas). Do not block heat dissipation around the product, i. e. , provide sufficient space for heat dissipation. Ensure that the rated voltage is reached within two seconds after the power is turned ON. after power is turned ON for correct measurement. · To prevent inductive noise, separate the terminal block wiring for the product from high-voltage or high-current power lines. Do not route the wiring for the product in parallel with or tie it in a bundle with power lines. Take the following countermeasures against inductive noise in input lines. Temperature Inputs Separate the lead wire that connects the product with a temperature sensor from the load line to prevent the product from being affected by inductive noise. · When using a noise filter for the power supply, check for the voltage and current and install it as close as possible to the Temperature Meter. · Do not install the product near radios, television sets, or wireless devices. Doing so may cause reception interference. Increasing Service Life · Do not use the product in locations where the temperature or humidity exceeds the ratings or where condensation may occur. When installing the product in a panel, be sure that the temperature around the product (not the temperature around the panel) does not exceed the ratings. To extend the product service life, lower the temperature inside the Temperature Meter. · Use and store the product within the temperature and humidity ranges given in the specifications. When gang-mounting Temperature Meters or arranging them vertically, heat generated by the Temperature Meters will cause the internal temperature to rise, reducing the service life. In such cases, consider forced cooling methods, such as using a fan to circulate air around the Temperature Meters. [. . . ] This information by itself is not sufficient for a complete determination of the suitability of the products in combination with the end product, machine, system, or other application or use. The following are some examples of applications for which particular attention must be given. This is not intended to be an exhaustive list of all possible uses of the products, nor is it intended to imply that the uses listed may be suitable for the products. · Outdoor use, uses involving potential chemical contamination or electrical interference, or conditions or uses not described in this catalog. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE OMRON K3MA-L




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual OMRON K3MA-L will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.