User manual OMRON K3HB-V

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual OMRON K3HB-V. We hope that this OMRON K3HB-V user guide will be useful to you.


OMRON K3HB-V : Download the complete user guide (3212 Ko)

Manual abstract: user guide OMRON K3HB-V

Detailed instructions for use are in the User's Guide.

[. . . ] N128-E1-01D K3HB-S/-X/-V/-H Digital Indicators USER'S MANUAL Preface Thank you for purchasing the K3HB. This manual describes the functions, performance, and application methods needed for optimum use of the K3HB. Please observe the following items when using the K3HB. · This product is designed for use by qualified personnel with a knowledge of electrical systems. · Read this manual carefully and make sure you understand it well to ensure that you are using the K3HB correctly. [. . . ] Simple Average Voltage/current input Functions and Operations 0. 5 ms Sampling Average Average Average Average Measurement values and comparative outputs refreshed 0. 5 ms × averaging times (4) = 2 ms Moving Average Voltage/current input 0. 5 ms Sampling Measurement values and comparative outputs refreshed 0. 5 ms 5-38 5. 13 Averaging Inputs · The data refresh periods when averaging is used are given by model in the following table. Set value No averaging Simple average 1 2 4 8 16 32 64 128 256 512 1024 Moving average L1 K3HB-X/V/H 20 ms 40 ms 80 ms 160 ms 320 ms 640 ms 1. 28 s 2. 56 s 5. 12 s 10. 24 s 20. 48 s 20 ms K3HB-S 0. 5 ms 1 ms 2 ms 4 ms 8 ms 16 ms 32 ms 64 ms 128 ms 256 ms 512 ms 0. 5 ms 1 to 1024 avg-t (AVG-T) Averaging is set using the following parameters. Parameter Average type avg-t Set value smpl move 1 2 4 8 16 Averaging times avg-n 32 64 128 256 512 1024 Meaning of set value Simple average Moving average 1 2 4 8 16 32 64 128 256 512 1024 L1 avg-n (AVG-N) Functions and Operations * To not use averaging, set the average type "avg-t" to smpl and the averaging times "avg-n" to 1. Parameter Setting Procedure A Press the L [LEVEL] Key for at least 3 s in RUN level to move to the initial setting level. · "L 0" is displayed on the level/bank display to indicate the initial setting level. L 3 s min. L 0 Displays "L 0. " 5-39 Section 5 Functions and Operations B Press the L [LEVEL] Key once (less than 1 s) to move to the input adjustment level. · "L 1" is displayed on the level/bank display to indicate the input adjustment level. C Press the M [MODE] Key several times to switch the PV display to "avg-t. " L Less than 1 s L 1 tmg-h nomal Displays "L 1. " M S L 1 avg-t smpl D Press the S [SHIFT] Key to make the SV display flash. · The setting can be changed when the SV display starts to flash. E Use the U [UP] Key to change the average type setting. L 1 avg-t smpl U M S U M L 1 avg-t move F Press the M [MODE] Key to change to the next parameter "avg-n. " · The average type setting is registered. G Press the S [SHIFT] Key to make the SV display flash. L 1 avg-n 1 L 1 avg-n 1 Functions and Operations H Use the U [UP] Key to change the averaging times setting. L 1 avg-n 4 I Press the M [MODE] Key to switch to the next parameter. · The averaging times setting is registered. L 1 memo off J Press the L [LEVEL] Key for at least 1 s to return to RUN level. L 1 s min. 1234. 5 Remarks Changing display refresh periods P. 5-73 5-40 5. 14 Detecting Sudden Input Changes 5. 14 Detecting Sudden Input Changes Advanced function setting level X V S H The previous average value comparison function can be used to detect only sudden changes in input signals. Explanation of Functions Previous average value comparison Use the previous average value comparison to not detect gentle changes and only detect sudden changes. Off-center As shown in the above diagram, when rotating a cylindrical object and measuring the distance from the object using a laser displacement meter, it cannot be judged if the increase in measurement values when the rotating axis is eccentric is due to the eccentricity or to a burr. Measurement Values Functions and Operations Measurements without using previous average value comparison Measurements using previous average value comparison 0 360° 5-41 Section 5 Functions and Operations Previous average value comparison makes the measurement value the difference between the present input value and the average of all previous input values. Number of measurements 1 2 3 4 · · · n Input value V1 V2 V3 V4 · · · Vn Display value V1-V1=0 V2-C1 V3-C2 V4-C3 · · · Vn-Cn-1 2 2 Comparative set value for next input C1=V1 --C2= 1 (C1+V2)= 1 (V1+V2) 2 C3= 1 (C2+V3)= 1 (V1+V2)+ 1 V3 ---2 4 2 C4= 1 (C3+V4)= 1 (V1+V2)+ 1 V3+ 1 V4 ----2 8 4 2 · · · 1 1 Cn= ------------ (V1+V2)+ ------------ V3+···+ 1 Vn -n­1 n­2 2 2 (Vn indicates the input value and Cn indicates the comparative set value used for the next input. ) * Previous average value comparison is performed on confirmed measurement values. · When the timing hold is set to Normal, the comparison is performed every time. · When the timing hold is set to a setting other than Normal, the comparison is performed on held values. Previous average value comparison is set using the following parameter. Lf hp-f (HP-F) Parameter Previous average value comparison hp-f Set value off on Meaning of set value Previous average value comparison disabled Previous average value comparison enabled Functions and Operations Parameter Setting Procedure A Press the L [LEVEL] Key for at least 3 s in RUN level to move to the initial setting level. · "L 0" is displayed on the level/bank display to indicate the initial setting level. B Press the M [MODE] Key several times to change the PV display to "amov. " · This parameter is not displayed for the initial status due to setting level protect. Refer to "Limiting Key Operations" (P. 5102) for information on removing setting level protect. · The setting can be changed when the SV display starts to flash. L 3 s min. L 0 Displays "L 0. " M L 0 amov 0 S L 0 amov 00000 5-42 5. 14 Detecting Sudden Input Changes D Use the U [UP] and S [SHIFT] Keys to set the password "-0169. " Press the M [MODE] Key to move to the advanced function setting level. [. . . ] Displayed only for certain models or settings. MODE M * Displayed when bank selection (bnk-c) is set to KEY. cmwt off CMWT: Communications write OFF, ON *Displayed only for Communications Units. Press the @ [LEVEL] key for at least 1 s from any display (except for the protect level) to return to the first parameter in the RUN or initial setting level. LEVEL L Password: -0169 LEVEL L 1 s min. 1 s max. Advanced function setting level L f Output test level L t init Set value initialization off OFF, ON <M INIT: test TEST: Test input off -19, 999 to 99, 999 LEVEL pass <M PASS: PASS output change pass LL, L, PASS, H, HH, ERR HYS: Hysteresis 0 to 9, 999 OFF-D: Output OFF-delay 0 to 1, 999 (100 ms) SHOT: Shot output 0 to 1, 999 (100 ms) OUT-N: Output logic N-O, N-C O-STP: Output refresh stop OFF, OUT, ALL HP-F: Previous average value comparison OFF, ON BNK-C: Bank selection OFF, KEY, EV S-TMR: Startup compensation timer 0. 0 to 99. 9 s S. ERR: Input error enable OFF, OVER, S. ERR L hys 1 Communications cations Units. L6 setting level 1 s max. Displayed only for Communi- u-no Communications 1 Unit No. 0 to 99 BPS: Baud rate <M U-NO: bps 9. 6, 19. 2, or 9. 6 38. 4 kbps <M len <M LEN: Data length 7 7 or 8 bits SBIT: Stop bits 2 1 or 2 bits MODE M sbit <M prty <M PRTY: Parity eVen None, even, or odd SDWT: Send wait time 20 0 to 99 ms sdwt L LEVEL 1 s max. Displayed for Linear Linear output level L 5 Output Units only. lset. c <M LSET. C: Linear current model 4-20 0 to 20 mA, 4 to 20 mA LSET. V: Linear voltage model 0 to 10 V stdby off STDBY: Standby sequence OFF, ON lset. V MODE 1-5 0 to 5 V, 1 to 5 V, LSET. H: Linear cjc on CJC: Cold junction compensation OFF, ON CMOV: Move to calibration level -19, 999 to 99, 999 M <M lset. h output upper limit 1300. 0 -19999 to 99999 <M lset. l output lower limit LSET. L: Linear - 200. 0 -19999 to 99999 Appendices A-24 About Parameters Input adjustment level L 1 Display adjustment level L 2 tmg-h on-t TMG-H: Timing hold nomal Normal, sampling, peak, bottom, peak-to-peak <M ON-T: ON timing delay 0 0 to 4, 999 (100 ms) OFF-T: OFF timing delay 0 to 4, 999 (100 ms) Z-LIM: Zero-limit OFF/ON LIM-P: Zero-limit value 0 to 99 sV. dsp SV. DSP: set value Comparative off display OFF, ON <M <M LEVEL L d. ref D. REF: Display refresh period off OFF, 0. 5 s, 1 s, 2 s, 4 s off-t 0 <M 1 s max. color <M <M COLOR: Display color selection grn-r Green (red), green, red (green), red z-lim off <M disp <M DISP: Display value selection pV PV, MAX, MIN RET: lim-p 0 <M MODE M ret Automatic display return 10 0 to 99 s <M step off <M STEP: Step value OFF, 2, 5, 10 AVG-T: Average type Simple average, moving average AVG-N: Averaging times 1, 2, 4, 8, 16, 32, 64, 128, 512, 1, 024 times ISI1: Input shift input value 1 pos-t <M inc (reversed), deviation, deviation (reversed) POS-T: Position meter type OFF, incremental, incremental MODE M aVg-t smpl <M pos-h <M POS-H: Position meter upper limit 1300. 0 -19, 999 to 99, 999 POS-L: aVg-n 1 <M pos-l Position meter lower limit -200. 0 -19, 999 to 99, 999 <M isi1 <M -200. 0 -19999 to 99999 pVdp off PVDP: PV decimal point OFF, ON iss1 <M 0. 00 -19999 to 99999 ISS1: Input shift value 1 LEVEL ISI2: Input shift input value 2 -19999 to 99999 ISS2: Input shift input value 2 -19999 to 99999 L isi2 1300. 0 <M 1 s max. Comparative set value level L 4 iss2 0. 00 <M sV. bnk 0SV. BNK: Comparative set value bank to 7 0 1 2 OFF. memo MEMO: Power interruption memory off OFF, ON Displayed when bank selection (bnk-c) is not set to U UP M SV0. HH: Comparative M set value 0. HH MODE -19, 999 to 99, 999 SV0. H: Comparative set value 0. H -19, 999 to 99, 999 SV0. L: Comparative set value 0. L -19, 999 to 99, 999 SV0. LL: Comparative set value 0. LL -19, 999 to 99, 999 COPY: Bank copy OFF, ON 7 M sV0. hh 99999 <M sV7. hh 99999 <M M MODE sV0. h 99999 <M sV7. h 99999 <M sV0. l - 9999 1 <M sV7. l - 9999 1 <M sV0. ll - 9999 1 sV7. ll - 9999 1 M M copy - ff o copy - ff o LEVEL L 1 s max. Changing the Settings Use the following method to change the settings. M Monitor mode 12345 S 4000 M Edit mode 12345 04000 M *If a key is not pressed within 5 s, the present setting will be saved and the display will return to monitor mode. Use the SU Keys to change the settings. The setting to be changed will flash. To next parameter. Appendices A-25 Appendices Sampling and Comparative Output Response Times The K3HB-S sampling and comparative output response times depend on the calculations, timing hold type, and, for simple averaging, the averaging times. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE OMRON K3HB-V




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual OMRON K3HB-V will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.