User manual OMRON JX
DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!
If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual OMRON JX. We hope that this OMRON JX user guide will be useful to you.
You may also download the following manuals related to this product:
OMRON JX (3475 ko)
OMRON JX (8583 ko)
OMRON JX (10210 ko)
OMRON JX (11511 ko)
OMRON JX (2262 ko)
OMRON JX (2256 ko)
OMRON JX (2966 ko)
OMRON JX (2266 ko)
OMRON JX (2255 ko)
OMRON JX (2253 ko)
OMRON JX (10206 ko)
OMRON JX (2370 ko)
OMRON JX (2262 ko)
OMRON JX (2266 ko)
OMRON JX (2256 ko)
OMRON JX MANUAL 2 (2258 ko)
OMRON JX MANUAL 2 (2263 ko)
OMRON JX MANUAL 2 (2266 ko)
OMRON JX MANUAL 2 (2261 ko)
OMRON JX MANUAL 2 (2259 ko)
OMRON JX MANUAL 2 (2267 ko)
OMRON JX MANUAL 2 (10959 ko)
OMRON JX DATASHEET (866 ko)
OMRON JX DATASHEET (789 ko)
OMRON JX DATASHEET (801 ko)
OMRON JX DATASHEET (798 ko)
OMRON JX DATASHEET (798 ko)
OMRON JX DATASHEET (1424 ko)
OMRON JX MANUAL 2 (2253 ko)
OMRON JX DATASHEET (957 ko)
Manual abstract: user guide OMRON JX
Detailed instructions for use are in the User's Guide.
[. . . ] I558-E2-02-X
JX
Compact and complete Model: JX 200 V Class Three-Phase Input 0. 2 to 7. 5 kW 200 V Class Single-Phase Input 0. 2 to 2. 2 kW 400 V Class Three-Phase Input 0. 4 to 7. 5 kW
USER'S MANUAL
Introduction
Introduction
Thank you for choosing the general-purpose Inverter JX. This User's Manual (hereinafter called "this manual") describes the parameter setting methods required for installation/wiring and operation of the JX model, as well as troubleshooting and inspection methods. This manual should be delivered to the actual end user of the product. This manual describes the specifications and functions of the product as well as the relations between them. [. . . ] A081 Function name AVR selection AVR voltage selection Data 00: Always ON 01: Always OFF 02: OFF during deceleration 200-V class: 200/215/220/230/240 400-V class: 380/400/415/440/460/480 d004, A001, A005 Default setting 02 Unit
A082
200/400
4
Related parameters
Functions
·With A081 (AVR selection), set whether to enable or disable this function. ·Note that the Inverter cannot output voltage beyond that of the incoming voltage. ·To avoid a possible overcurrent trip during deceleration, set the AVR selection to "Always ON" (A081: 00).
Parameter No. Data 00 01 Description Always ON Always OFF OFF during deceleration Note Enabled during acceleration, constant speed operation, and deceleration. Disabled during acceleration, constant speed operation, and deceleration. Disabled only during deceleration in order to reduce the energy regenerated to the Inverter by increasing the motor loss. This will avoid a possible trip due to regeneration during deceleration.
A081
02
Automatic Energy-saving Operation Function
This function automatically adjusts the Inverter output power to a minimum during constant speed operation. This is suitable for the load of reduced torque characteristics, such as a fan and pump.
Parameter No. A085 A086 Function name RUN mode selection Data 00: Normal operation 01: Energy-saving operation Default setting 00 50 Unit %
Energy-saving response/ 0 to 100% accuracy adjustment
·To operate with this function, set the RUN mode selection (A085) to 01. You can adjust the response and accuracy in the energy-saving response/accuracy adjustment (A086). If rapid load fluctuation like impact load occur the motor may stall resulting in an overcurrent trip.
Parameter No. Data 0 A086 100 Fast Low Large Response Slow Accuracy High Energy-saving effect Small
4-26
4-2 Function Mode
2-step Acceleration/Deceleration Function
This function changes the acceleration/deceleration time during such operations.
Parameter No. A092
*
Function name Acceleration time 2 2nd acceleration time 2 Deceleration time 2 2nd deceleration time 2 2-step acceleration/ deceleration selection 0. 01 to 99. 99 100. 0 to 999. 9 1000. to 3000.
Data
Default setting 15. 0 15. 0 15. 0 15. 0 00
Unit s s s s
A292
A093
*
A293
A094
*
A294
A095
*
A295
A096
*
A296
00: Switched via multi-function input 09 (2CH) 01: Switched by setting 00: Switched via multi-function input 09 2nd 2-step acceleration/ (2CH) deceleration selection 01: Switched by setting 2-step acceleration 0. 0 to 400 frequency 2nd 2-step acceleration 0. 0 to 400 frequency 2-step deceleration 0. 0 to 400 frequency *2nd 2-step deceleration 0. 0 to 400 frequency Related parameters
4
00 0. 0 0. 0 0. 0 0. 0
Functions
Hz Hz Hz Hz
F002, F003, F202, F203, C001 to C005
* To switch to the 2nd control, allocate 08 (SET) to the multi-function input terminal and then turn it on. ·The acceleration/deceleration time can be switched via the multi-function input terminal or automatically with an arbitrary frequency. ·To switch via the multi-function input terminal, allocate 09 (2CH) to it. it
Data 09 Symbol 2CH Function name 2-step acceleration/deceleration OFF Status ON Description Enables the 2-step acceleration/ deceleration time. Disables the 2-step acceleration/ deceleration time.
Related parameters
Required settings (Example 1) When A094/A294 is set to 00
FW
C001 to C005 A094 = 00 (Example 2) When A094/A294 is set to 01
FW
2CH
Acceleration 2 Deceleration 2 Acceleration 2 A095/A295 Deceleration 1 Acceleration 1 Deceleration 1 A096/A296 Deceleration 2
Acceleration 1
Output frequency
Output frequency
F002/F202 A092/A292 A093/A293 F003/F203
F002/F202 A092/A292 A093/A293 F003/F203
4-27
4-2 Function Mode
Acceleration/Deceleration Pattern
This function is used when smooth acceleration/deceleration is needed.
Parameter No. A097 A098 Function name Acceleration pattern selection Deceleration pattern selection Data 00: Line 01: S-shape curve 00: Line 01: S-shape curve Default setting 00 00 Unit
·Acceleration/deceleration pattern can be set according to each system.
4
Parameter No. 00 Line
Set value 01 S-shape curve
Functions
A097 (Acceleration)
Output frequency
Output frequency
Time
Time
A098 (Deceleration)
Output frequency
Time
Output frequency
Time
Description
Accelerates/Decelerates linearly before reaching the set output frequency value.
Helps prevent the collapse of cargo on the elevating machine or conveyor.
External Frequency Adjustment Function (OI)
Parameter No. A101 A102 A103 A104 A105 Function name OI start frequency OI end frequency OI start ratio OI end ratio OI start selection Related parameters 0. 00 to 400. 0 0. 00 to 400. 0 0. 01 Unit Hz Hz % %
A005, A011 to A015, A016, A151 to A155, AT input
For each item, refer to "External Frequency (Voltage/Current) Adjustment" (page 4-11).
4-28
4-2 Function Mode
Operation Frequency Function
This function makes calculations for two inputs and reflects the result as the output frequency.
Parameter No. A141 A142 Function name Operation frequency input A setting Operation frequency input B setting Operator selection Related parameters Data 00: Digital Operator (F001) 01: Digital Operator (FREQ adjuster) 02: Input O 03: Input OI 04: RS485 communication 00: Addition (A + B) 01: Subtraction (A - B) 02: Multiplication (A × B) A001 = 10 Default setting 01 02 Unit
A143
00
4
·Inputs O and OI cannot be set simultaneously. [. . . ] 01
No No No No No No
Hz Hz % %
VR start frequency 0. 0 to 400. 0 VR end frequency VR start ratio VR end ratio VR start selection 0. 0 to 400. 0 0. 00: Use VR start frequency [A151] 01: 0 Hz start
VR adjustment
A152 A153 A154 A155
* 2nd control is displayed when SET (08) is allocated to one of from C001 to C005.
App-9
Appendix-1 Parameter List
Parameter No.
Function name
Monitor or data range (Digital Operator) 00: Alarm 01: 0 Hz start 02: Frequency Matching start 03: Trip after Frequency Matching deceleration stop 0. 3 to 25. 0 0. 3 to 100. 0
Default setting
Changes during operation
Unit
Set value
b001 Restart during momentary power interruption
Retry selection
00
No
b002 b003
Allowable momentary power interruption time Retry wait time Momentary power interruption/ undervoltage trip during stop selection Momentary power interruption retry time selection Starting frequency at Active Frequency Matching restart Electronic thermal level *2nd electronic thermal level Electronic thermal characteristics selection *2nd electronic thermal characteristics selection
1. 0 1. 0
No No
s s
b004
00: Disabled 01: Enabled
00
No
b005
00: 16 times 01: No limit 00: Frequency at interruption 01: Max. frequency 02: Set frequency
00
No
b011
00
No
b012 Electronic thermal b212
0. 2 × Rated current to 1. 0 × Rated current
Rated current Rated current 00
No
A
b013
b213
00: Reduced torque characteristics 1 01: Constant torque characteristics 02: Reduced torque characteristics 2
No 00
* 2nd control is displayed when SET (08) is allocated to one of from C001 to C005.
App-10
Appendix-1 Parameter List
Parameter No. b021 b221
Function name Overload limit selection *2nd overload limit selection Overload limit level
Monitor or data range (Digital Operator) 00: Disabled 01: Enabled in acceleration/constant speed operation 02: Enabled in constant speed operation
Default setting 01
Changes during operation
Unit
Set value
No 01 1. 5 × Rated current 1. 5 × Rated current 1. 0
b022 Overload limit
0. . 1 × Rated current to 1. 5 × Rated current b222 *2nd overload limit level Overload limit parameter *2nd overload limit parameter Overload limit source selection *2nd overload limit source selection Deceleration rate constant at Active Frequency Matching restart Active Frequency Matching restart level
No
A
b023 b223 b028 b228
0. 1 to 3000. 0 1. 0 00
No
s
00: b022, b222 set values 01: Input terminal O
No 00
Active Frequency Matching
b029
0. 1 to 3000. 0
0. 5
No
s
b030
0. 2 × Rated current to 2. 0 × Rated current
Rated current
No
A
b031
Soft lock selection
00: Data other than b031 cannot be changed when terminal SFT is ON. [. . . ]