User manual OMRON J1000

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual OMRON J1000. We hope that this OMRON J1000 user guide will be useful to you.


OMRON J1000 : Download the complete user guide (6967 Ko)

You may also download the following manuals related to this product:

   OMRON J1000 DATASHEET (1498 ko)
   OMRON J1000 DATASHEET (4361 ko)

Manual abstract: user guide OMRON J1000

Detailed instructions for use are in the User's Guide.

[. . . ] SIEP-C71060633-01-OY J1000 Compact General Purpose Inverter Model: JZA 200 V Class Three-Phase Input 0. 1 to 0. 4 kW 200 V Class Single-Phase Input 0. 1 to 1. 5 kW 400 V Class Three-Phase Input 0. 2 to 4. 0 kW USER'S MANUAL OYMC AC Drive ­ J1000 Compact V/f Control Drive User Manual Type: JZA Model: 200 V Class, Single-Phase Input: 0. 1 to 1. 5 kW 200 V Class, Three-Phase Input: 0. 1 to 4. 0 kW 400 V Class, Three-Phase Input: 0. 2 to 4. 0 kW To properly use the product, read this manual thoroughly and retain for easy reference, inspection, and maintenance. Ensure the end user receives this manual. Receiving 1 2 3 4 5 6 7 8 A B C D Mechanical Installation Electrical Installation Start-Up Programming & Operation Parameter Details Troubleshooting Periodic Inspection & Maintenance Peripheral Devices & Options Specifications Parameter List MEMOBUS/Modbus Communications MANUAL NO. SIEP C710606 33A Standards Compliance Copyright © 2008 OMRON YASKAWA MOTION CONTROL, B. V. No part of this publication may be reproduced, stored in a retrieval system, or transmitted, in any form or by any means, mechanical, electronic, photocopying, recording, or otherwise, without the prior written permission of OYMC. [. . . ] Check monitor U4-06 for the performance life of the inrush prevention circuit. Replace the drive if U4-06 exceeds 90%. 128 SIEP C710606 33A OYMC AC Drive ­ J1000 User Manual 6. 5 Alarm Detection 6. 5 Alarm Detection Alarms are drive protection functions that do not operate the fault contact. The drive will return to original status when the cause of the alarm has been removed. During an alarm condition, the Digital Operator display flashes and an alarm output is generated at the multi-function output (H2-01), if programmed. Investigate the cause of the alarm and refer to Table 6. 8 for the appropriate action. u Alarm Codes, Causes, and Possible Solutions LED Operator Display bb Cause Table 6. 8 Alarm Codes, Causes, and Possible Solutions Minor Fault Name Baseblock Drive output interrupted as indicated by an external baseblock signal. Possible Solutions Minor Fault (H2-01 = 10) No output External baseblock signal entered via multi-function input terminal (S1 to S5). LED Operator Display Minor Fault Name Serial Communication Transmission Error CALL Communication has not yet been established. Cause Communications wiring is faulty, there is a short circuit, or something is not connected properly. LED Operator Display CE Cause · · · · Possible Solutions · Check for wiring errors. The terminal slave drive must have the internal terminal resistance switch set correctly. Minor Fault Name MEMOBUS/Modbus Communication Error Control data was not received correctly for two seconds. Possible Solutions Minor Fault (H2-01 = 10) YES YES YES YES Minor Fault (H2-01 = 10) Check options available to minimize the effects of noise. Counteract noise in the control circuit wiring, main circuit lines and ground wiring. Use surge absorbers on magnetic contactors or other equipment causing the A data error occurred due to noise. · Use cables recommended by OYMC or another type of shielded line. The shield should be grounded on the controller side or on the drive input power side. · Separate all wiring for communications devices from drive input power lines. · Check the H5 parameter settings as well as the protocol setting in the controller. Communications cable is disconnected or · Check the connector for a signal through the cable. LED Operator Display Minor Fault Name CrST Can Not Reset Cause Possible Solutions YES YES Troubleshooting YES YES YES Minor Fault Output (H2-01 = 10) YES 6 a run command cannot be entered from the external terminals or option Fault reset was being executed when a run · Ensure that fault reset. LED Operator Display Minor Fault Name Forward/Reverse Run Command Input Error EF Both forward run and reverse run closed simultaneously for over 0. 5 s. Cause Sequence error Possible Solutions Check the forward and reverse command sequence and correct the problem. [. . . ] 181 U4: Maintenance Monitors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 182 U4-01 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 182 U4-04 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 182 U4-05 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE OMRON J1000




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual OMRON J1000 will begin.

 