Detailed instructions for use are in the User's Guide.
[. . . ] · Compact (80 mm) body.
Model Number Structure
Model Number Legend
H7GP-Case Color of Front Section None: Light gray (Munsell 5Y7/1) B: Black
Ordering Information
List of Models
Supply voltage 100 to 240 VAC 12 to 24 VDC H7GP-C H7GP-CD 6-digit total counter Light gray H7GP-CB H7GP-CDB Black H7GP-T H7GP-TD 6-digit time counter Light gray H7GP-TB H7GP-TDB Black
2
Total Counter/Time Counter (DIN 48 x 24) H7GP
Specifications
Ratings
Item Rated supply voltage External power supply Operating voltage range Power consumption Dimensions Mounting method External connections Degree of protection Display Digits Input mode Max. counting speeds Counting range Time specification Timing accuracy Memory backup Input Input signals Input method Count, reset, start 6-digit total counter H7GP-C 100 to 240 VAC (50/60 Hz) 50 mA at 12 VDC H7GP-CD 12 to 24 VDC (see note 1) --6-digit time counter H7GP-T 100 to 240 VAC (50/60 Hz) 50 mA at 12 VDC H7GP-TD 12 to 24 VDC (see note 1) ---
85% to 110% of rated supply voltage 100 to 240 VAC: 6. 5 VA max. 48 x 24 x 80 mm (W x H x D) Flush mounting Screw terminals Panel surface: JEM IP66G and NEMA Type 4 (indoors) 7-segment, negative transmissive LCD (with red backlight) 6 digits (8. 5-mm-high characters) Up (increment) 30 Hz or 5 kHz (selected via DIP switch) 0 to 999999 ----EEP-ROM: 200, 000 operations min. [. . . ] Incremented for count 1 (CP1) inputs; decremented for count 2 (CP2) inputs. Non-contact input is also available.
AC Models
H7HP-A
100 to 240 VAC External power supply 12 VDC 50 mA max.
H7HP-C8
100 to 240 VAC External power supply 12 VDC 50 mA max.
Power supply
Power supply
Unused Unused Unused
0V
12 VDC
Power supply
Power supply
Unused Unused Unused
0V
12 VDC
5
6 1
Key protection input
7 2
Reset input
8 3
9 4
10
11
5
6 1
Key protection input
7 2
Reset input
8 3
9 4
10
11
Count 1 Count 2 input or input or start input gate input
Count 1 Count 2 input input
NPN mode PNP mode
NPN mode PNP mode
DC Models
H7HP-AD
12 to 24 VDC
H7HP-C8D
12 to 24 VDC
0V
Power supply
Unused Unused Unused Unused Unused
0V
Power supply
Unused Unused Unused Unused Unused
5
6 1
Key protection input
7 2
Reset input
8 3
9 4
10
11
5
6 1
Key protection input
7 2
Reset input
8 3
9 4
10
11
Count 1 Count 2 input or input or start input gate input
Count 1 Count 2 input input
NPN mode PNP mode NPN mode PNP mode
Operation
DIP Switch Settings
Switches 1 to 4 are all set to OFF before shipping.
H7HP-C8/-C8D
Pin no. 1 2 Item Unused Counting speed Unused --30 Hz --OFF --5 kHz PNP --ON
H7HP-A/-AD
Pin no. 1 2 3 4 Item Function Counting speed Time range Unused 30 Hz 99999. 9 h --OFF Total counter 5 kHz 99 h 59 min 59 s PNP --ON Time counter
3 4
Input mode (note) NPN
Note: When the setting has been changed, turned power off and on to continue. The display will show "0" when the power is turned back on.
Input mode (note) NPN
Total Counter/Time Counter (DIN 72 x 36)
H7HP
11
Operating Modes
Total Counters
Reset input AC (10-2) DC (5-2) CP1 AC (10-3) DC (5-3) CP2 AC (10-4) DC (5-4) 999999 (see note)
Display
0
-99999 (see note) display
Note: Display values are shown for a 6-digit model. The count value will return to "0" when "999999" is exceeded.
Time Counters
Reset input AC (10-2) DC (5-2) Gate input AC (10-4) DC (5-4) Start input AC (10-3) DC (5-3) 99999. 9h (see note 1)
Display 0. 0 h
Note: 1. The count value will return to "0" when "99999. 9" is exceeded. Gate input is available only when H7HP-A settings are made.
Nomenclature
2
(The figure shows the DIP switch label stuck to the rear of the case. )
1
3
1. Reset Key Resets the count value, but will not operate while the keys are protected. Key Protection Indicator Lit while the keys are protected (Reset Key is disabled. ). Refer to DIP Switch Settings for details.
12
Total Counter/Time Counter (DIN 72 x 36) H7HP
Dimensions
Note: All units are in millimeters unless otherwise indicated.
H7HP-A H7HP-C8
M3. 5 terminal screw
Terminal cover (provided)
Panel Cutouts Panel cutouts are as shown below (according to DIN43700).
Note: 1. Water resistance will be lost if Counters are mounted side-by-side.
With Flush Mounting Bracket
Y92S-33 rubber packing (provided) Panel Y92F-33 flush mounting adaptor (provided)
Total Counter/Time Counter (DIN 72 x 36)
H7HP
13
Connections (Common)
Input Connections
Note: The undermentioned is common for all H7GP/H7HP models.
No-voltage Input (NPN Input Mode)
Reset, Count 1, Count 2, Start, and Gate Inputs
Open Collector Output
H7GP/H7HP
Voltage Output
12 VDC (12 to 24 VDC)
Sensor
12 VDC (12 to 24 VDC)
Sensor
12 VDC (12 to 24 VDC)
Reset, Count 1, Count 2, Start, and Gate Inputs Specification
Short-circuit (ON) impedance: 1 k max. Note: Two-wired sensors cannot be used.
Reset input Count 1 input Count 2 input Start input Gate input
0V
Reset input Count 1 input Count 2 input Start input Gate input
0V
Key Protection Input
Open Collector Output
H7GP/H7HP
Voltage Output
12 VDC (12 to 24 VDC)
Sensor
Sensor
12 VDC (12 to 24 VDC)
Key Protection Inputs Specification
Short-circuit (ON) impedance: Short-circuit (ON) residual voltage: Current flow for 0- short-circuit: Open (OFF) impedance: 1 k max. 0. 5 mA 100 k min.
Key protection input
0V
Key protection input
0V
Note: Two-wired sensors cannot be used.
Voltage Input (PNP Input Mode)
Reset, Count 1, Count 2, Start, and Gate Inputs
Sensor
12 VDC (12 to 24 VDC)
Reset, Count 1, Count 2, Start, and Gate Inputs Specification
Short-circuit (ON) impedance: 1 k max. Note: Two-wired sensors cannot be used.
Reset input Count 1 input Count 2 input Start input Gate input
0V
14
Total Counter/Time Counter H7GP/H7HP
Safety Precautions (Common)
Note: The undermentioned is common for all H7GP/H7HP models.
!CAUTION
This may occasionally cause electric shock, fire, or malfunction. Do not allow metal fragments or lead wire scraps to fall inside the H7GP/H7HP.
· Although the H7GP/H7HP power supply (primary side) is isolated from control circuits (secondary side) by a transformer, the primary and secondary sides of the transformer are linked by a capacitor, making it possible for high-frequency components to leak to the secondary side. Do not connect input circuits to exposed parts (such as the machine body) and be sure that the power supply is turned off before wiring.
Control circuit Display circuit
Precautions for Safe Use
Observe the following items to ensure the safe use of this product.
Environmental Precautions
· Store the H7GP/H7HP within the specified ratings. If the H7GP/ H7HP has been stored at temperatures -10°C or lower, let it stand for 3 hours or longer at room temperature before turning ON the power supply. · Use the H7GP/H7HP within the specified ratings for operating temperature and humidity. · Do not operate the H7GP/H7HP in locations subject to sudden or extreme changes in temperature, or locations where high humidity may result in condensation. · Do not use the H7GP/H7HP in locations subject to vibrations or shock. · Do not use the H7GP/H7HP in locations subject to excessive dust, corrosive gas, or direct sunlight. [. . . ] LIMITATIONS OF LIABILITY OMRON SHALL NOT BE RESPONSIBLE FOR SPECIAL, INDIRECT, OR CONSEQUENTIAL DAMAGES, LOSS OF PROFITS, OR COMMERCIAL LOSS IN ANY WAY CONNECTED WITH THE PRODUCTS, WHETHER SUCH CLAIM IS BASED ON CONTRACT, WARRANTY, NEGLIGENCE, OR STRICT LIABILITY. In no event shall the responsibility of OMRON for any act exceed the individual price of the product on which liability is asserted. IN NO EVENT SHALL OMRON BE RESPONSIBLE FOR WARRANTY, REPAIR, OR OTHER CLAIMS REGARDING THE PRODUCTS UNLESS OMRON'S ANALYSIS CONFIRMS THAT THE PRODUCTS WERE PROPERLY HANDLED, STORED, INSTALLED, AND MAINTAINED AND NOT SUBJECT TO CONTAMINATION, ABUSE, MISUSE, OR INAPPROPRIATE MODIFICATION OR REPAIR.
Application Considerations
SUITABILITY FOR USE OMRON shall not be responsible for conformity with any standards, codes, or regulations that apply to the combination of products in the customer's application or use of the products. Take all necessary steps to determine the suitability of the product for the systems, machines, and equipment with which it will be used. [. . . ]