User manual OMRON H7HP DATASHEET

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual OMRON H7HP. We hope that this OMRON H7HP user guide will be useful to you.


OMRON H7HP DATASHEET: Download the complete user guide (421 Ko)

You may also download the following manuals related to this product:

   OMRON H7HP (891 ko)
   OMRON H7HP (957 ko)
   OMRON H7HP (432 ko)
   OMRON H7HP DATASHEET (349 ko)
   OMRON H7HP DATASHEET (600 ko)

Manual abstract: user guide OMRON H7HPDATASHEET

Detailed instructions for use are in the User's Guide.

[. . . ] · Compact (80 mm) body. Model Number Structure Model Number Legend H7GP-Case Color of Front Section None: Light gray (Munsell 5Y7/1) B: Black Ordering Information List of Models Supply voltage 100 to 240 VAC 12 to 24 VDC H7GP-C H7GP-CD 6-digit total counter Light gray H7GP-CB H7GP-CDB Black H7GP-T H7GP-TD 6-digit time counter Light gray H7GP-TB H7GP-TDB Black 2 Total Counter/Time Counter (DIN 48 x 24) H7GP Specifications Ratings Item Rated supply voltage External power supply Operating voltage range Power consumption Dimensions Mounting method External connections Degree of protection Display Digits Input mode Max. counting speeds Counting range Time specification Timing accuracy Memory backup Input Input signals Input method Count, reset, start 6-digit total counter H7GP-C 100 to 240 VAC (50/60 Hz) 50 mA at 12 VDC H7GP-CD 12 to 24 VDC (see note 1) --6-digit time counter H7GP-T 100 to 240 VAC (50/60 Hz) 50 mA at 12 VDC H7GP-TD 12 to 24 VDC (see note 1) --- 85% to 110% of rated supply voltage 100 to 240 VAC: 6. 5 VA max. 48 x 24 x 80 mm (W x H x D) Flush mounting Screw terminals Panel surface: JEM IP66G and NEMA Type 4 (indoors) 7-segment, negative transmissive LCD (with red backlight) 6 digits (8. 5-mm-high characters) Up (increment) 30 Hz or 5 kHz (selected via DIP switch) 0 to 999999 ----EEP-ROM: 200, 000 operations min. [. . . ] Incremented for count 1 (CP1) inputs; decremented for count 2 (CP2) inputs. Non-contact input is also available. AC Models H7HP-A 100 to 240 VAC External power supply 12 VDC 50 mA max. H7HP-C8 100 to 240 VAC External power supply 12 VDC 50 mA max. Power supply Power supply Unused Unused Unused 0V 12 VDC Power supply Power supply Unused Unused Unused 0V 12 VDC 5 6 1 Key protection input 7 2 Reset input 8 3 9 4 10 11 5 6 1 Key protection input 7 2 Reset input 8 3 9 4 10 11 Count 1 Count 2 input or input or start input gate input Count 1 Count 2 input input NPN mode PNP mode NPN mode PNP mode DC Models H7HP-AD 12 to 24 VDC H7HP-C8D 12 to 24 VDC 0V Power supply Unused Unused Unused Unused Unused 0V Power supply Unused Unused Unused Unused Unused 5 6 1 Key protection input 7 2 Reset input 8 3 9 4 10 11 5 6 1 Key protection input 7 2 Reset input 8 3 9 4 10 11 Count 1 Count 2 input or input or start input gate input Count 1 Count 2 input input NPN mode PNP mode NPN mode PNP mode Operation DIP Switch Settings Switches 1 to 4 are all set to OFF before shipping. H7HP-C8/-C8D Pin no. 1 2 Item Unused Counting speed Unused --30 Hz --OFF --5 kHz PNP --ON H7HP-A/-AD Pin no. 1 2 3 4 Item Function Counting speed Time range Unused 30 Hz 99999. 9 h --OFF Total counter 5 kHz 99 h 59 min 59 s PNP --ON Time counter 3 4 Input mode (note) NPN Note: When the setting has been changed, turned power off and on to continue. The display will show "0" when the power is turned back on. Input mode (note) NPN Total Counter/Time Counter (DIN 72 x 36) H7HP 11 Operating Modes Total Counters Reset input AC (10-2) DC (5-2) CP1 AC (10-3) DC (5-3) CP2 AC (10-4) DC (5-4) 999999 (see note) Display 0 -99999 (see note) display Note: Display values are shown for a 6-digit model. The count value will return to "0" when "999999" is exceeded. Time Counters Reset input AC (10-2) DC (5-2) Gate input AC (10-4) DC (5-4) Start input AC (10-3) DC (5-3) 99999. 9h (see note 1) Display 0. 0 h Note: 1. The count value will return to "0" when "99999. 9" is exceeded. Gate input is available only when H7HP-A settings are made. Nomenclature 2 (The figure shows the DIP switch label stuck to the rear of the case. ) 1 3 1. Reset Key Resets the count value, but will not operate while the keys are protected. Key Protection Indicator Lit while the keys are protected (Reset Key is disabled. ). Refer to DIP Switch Settings for details. 12 Total Counter/Time Counter (DIN 72 x 36) H7HP Dimensions Note: All units are in millimeters unless otherwise indicated. H7HP-A H7HP-C8 M3. 5 terminal screw Terminal cover (provided) Panel Cutouts Panel cutouts are as shown below (according to DIN43700). Note: 1. Water resistance will be lost if Counters are mounted side-by-side. With Flush Mounting Bracket Y92S-33 rubber packing (provided) Panel Y92F-33 flush mounting adaptor (provided) Total Counter/Time Counter (DIN 72 x 36) H7HP 13 Connections (Common) Input Connections Note: The undermentioned is common for all H7GP/H7HP models. No-voltage Input (NPN Input Mode) Reset, Count 1, Count 2, Start, and Gate Inputs Open Collector Output H7GP/H7HP Voltage Output 12 VDC (12 to 24 VDC) Sensor 12 VDC (12 to 24 VDC) Sensor 12 VDC (12 to 24 VDC) Reset, Count 1, Count 2, Start, and Gate Inputs Specification Short-circuit (ON) impedance: 1 k max. Note: Two-wired sensors cannot be used. Reset input Count 1 input Count 2 input Start input Gate input 0V Reset input Count 1 input Count 2 input Start input Gate input 0V Key Protection Input Open Collector Output H7GP/H7HP Voltage Output 12 VDC (12 to 24 VDC) Sensor Sensor 12 VDC (12 to 24 VDC) Key Protection Inputs Specification Short-circuit (ON) impedance: Short-circuit (ON) residual voltage: Current flow for 0- short-circuit: Open (OFF) impedance: 1 k max. 0. 5 mA 100 k min. Key protection input 0V Key protection input 0V Note: Two-wired sensors cannot be used. Voltage Input (PNP Input Mode) Reset, Count 1, Count 2, Start, and Gate Inputs Sensor 12 VDC (12 to 24 VDC) Reset, Count 1, Count 2, Start, and Gate Inputs Specification Short-circuit (ON) impedance: 1 k max. Note: Two-wired sensors cannot be used. Reset input Count 1 input Count 2 input Start input Gate input 0V 14 Total Counter/Time Counter H7GP/H7HP Safety Precautions (Common) Note: The undermentioned is common for all H7GP/H7HP models. !CAUTION This may occasionally cause electric shock, fire, or malfunction. Do not allow metal fragments or lead wire scraps to fall inside the H7GP/H7HP. · Although the H7GP/H7HP power supply (primary side) is isolated from control circuits (secondary side) by a transformer, the primary and secondary sides of the transformer are linked by a capacitor, making it possible for high-frequency components to leak to the secondary side. Do not connect input circuits to exposed parts (such as the machine body) and be sure that the power supply is turned off before wiring. Control circuit Display circuit Precautions for Safe Use Observe the following items to ensure the safe use of this product. Environmental Precautions · Store the H7GP/H7HP within the specified ratings. If the H7GP/ H7HP has been stored at temperatures -10°C or lower, let it stand for 3 hours or longer at room temperature before turning ON the power supply. · Use the H7GP/H7HP within the specified ratings for operating temperature and humidity. · Do not operate the H7GP/H7HP in locations subject to sudden or extreme changes in temperature, or locations where high humidity may result in condensation. · Do not use the H7GP/H7HP in locations subject to vibrations or shock. · Do not use the H7GP/H7HP in locations subject to excessive dust, corrosive gas, or direct sunlight. [. . . ] LIMITATIONS OF LIABILITY OMRON SHALL NOT BE RESPONSIBLE FOR SPECIAL, INDIRECT, OR CONSEQUENTIAL DAMAGES, LOSS OF PROFITS, OR COMMERCIAL LOSS IN ANY WAY CONNECTED WITH THE PRODUCTS, WHETHER SUCH CLAIM IS BASED ON CONTRACT, WARRANTY, NEGLIGENCE, OR STRICT LIABILITY. In no event shall the responsibility of OMRON for any act exceed the individual price of the product on which liability is asserted. IN NO EVENT SHALL OMRON BE RESPONSIBLE FOR WARRANTY, REPAIR, OR OTHER CLAIMS REGARDING THE PRODUCTS UNLESS OMRON'S ANALYSIS CONFIRMS THAT THE PRODUCTS WERE PROPERLY HANDLED, STORED, INSTALLED, AND MAINTAINED AND NOT SUBJECT TO CONTAMINATION, ABUSE, MISUSE, OR INAPPROPRIATE MODIFICATION OR REPAIR. Application Considerations SUITABILITY FOR USE OMRON shall not be responsible for conformity with any standards, codes, or regulations that apply to the combination of products in the customer's application or use of the products. Take all necessary steps to determine the suitability of the product for the systems, machines, and equipment with which it will be used. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE OMRON H7HP




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual OMRON H7HP will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.