User manual OMRON H3CR

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual OMRON H3CR. We hope that this OMRON H3CR user guide will be useful to you.


OMRON H3CR : Download the complete user guide (2219 Ko)

You may also download the following manuals related to this product:

   OMRON H3CR (977 ko)
   OMRON H3CR (4265 ko)
   OMRON H3CR (3727 ko)
   OMRON H3CR (1730 ko)
   OMRON H3CR (1119 ko)
   OMRON H3CR (861 ko)

Manual abstract: user guide OMRON H3CR

Detailed instructions for use are in the User's Guide.

[. . . ] Solid-state Timer H3CR Please read and understand this catalog before purchasing the products. Please consult your OMRON representative if you have any questions or comments. Refer to Warranty and Application Considerations (page 52), and Safety Precautions (page 22, 44, 51). DIN 48 × 48-mm Multifunctional Timer Series · Conforms to EN61812-1 and IEC60664-1 4 kV/2 for Low Voltage, and EMC Directives. · Six-language instruction manual provided. Broad Line-up of H3CR Series H3CR H3CR-A H3CR-F H3CR-G H3CR-H Multifunctional Timer H3CR-A H3CR-AS H3CR-AP H3CR-A8 H3CR-A8S H3CR-A8E 11-pin model 8-pin model 8-pin with instantaneous contact output model Twin Timer Star-delta Timer Power OFF-delay Timer H3CR-HRL 11-pin model H3CR-H8L 8-pin model H3CR-H8RL H3CR-F H3CR-G8L 8-pin model H3CR-FN 11-pin model H3CR-G8EL H3CR-F-300 H3CR-FN-300 H3CR-F8 H3CR-F8N 8-pin model H3CR-F8-300 H3CR-F8N-300 Note: H3CR-AS, H3CR-A8S: Transistor output models Contents Solid-state Timer H3CR-A. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . [. . . ] 100 g Note: Refer to the Life-test Curve. 26 Solid-state Twin Timers H3CR-F Life-test Curve 10, 000 Switching operations (x 103) 5, 000 1, 000 500 30 VDC L/R = 7 ms 250 VAC/30 VDC (cos = 1) Reference: A maximum current of 0. 15 A can be switched at 125 VDC (cos = 1) and a maximum current of 0. 1 A can be switched if L/R is 7 ms. The minimum applicable load is 10 mA at 5 VDC (failure level: P). 100 250 VAC (cos = 0. 4) Load current (A) Connections Block Diagrams ON indicator OFF indicator Zero setting detection circuit Indicator circuit ROM RAM Clock Output circuit AC (DC) input Power supply circuit One-chip microcomputer Time range/unit selectors I/O Functions Inputs Outputs Control output --Outputs are turned ON/OFF according to the time set by the ON- and OFF-time setting knob. Terminal Arrangement H3CR-F8 H3CR-F8 NH3CR-F8-300 H3CR-F8N-300 H3CR-F H3CR-FN H3CR-F-300 H3CR-FN-300 (+)(~) Power supply Power supply Note: Leave terminals 5, 6, and 7 open. Do not use them as relay terminals. Solid-state Twin Timers H3CR-F 27 Operation Timing Chart tON: ON set time tOFF: OFF set time Operating mode Flicker OFF start Power ON OFF Timing chart 0. 1 s min. tOFF tON tOFF tON tOFF tOFF Lit ON indicator Not lit OFF Lit indicator Not lit Output NO ON OFF ON OFF 0. 1 s min. Output NC Flicker ON start Power ON OFF tON tOFF tON tOFF tON tOFF Lit ON indicator Not lit Lit OFF indicator Not lit Output NO ON OFF ON OFF Output NC Note: 1. When power is supplied in flicker ON start mode, the OFF indicator lights momentarily. This, however, has no effect on the performance of the Timer. Nomenclature OFF indicator (green) Lit when the output is OFF. OFF-time unit display window OFF-time unit selector (select one from sec. 10 s, min. , and hrs, or from 10 s, 10 min, hrs, and 10 h) Scale range display windows ON-time setting knob (with orange pointer) For ON-time setting OFF-time setting knob (with green pointer) For OFF-time setting Time range selector (select one from 1. 2, 3, 12, and 30 at full scale) For both ON-time and OFF-time. ON-time unit display window ON-time unit selector (select one from sec, 10 s, min, and hrs, or from 10 s, 10 min, hrs, and 10 h) 28 Solid-state Twin Timers H3CR-F Dimensions Note: All units are in millimeters unless otherwise indicated. H3CR-F H3CR-FN H3CR-F-300 H3CR-FN-300 48 48 17. 4 5. 7 6 66. 6 52. 3 0. 7 37 dia. 14 dia. 44. 8 × 44. 8 R1. 3 11 pins H3CR-F8 H3CR-F8N H3CR-F8-300 H3CR-F8N-300 48 48 17. 4 5. 7 6 66. 6 52. 3 0. 7 37 dia. 14 dia. 44. 8 × 44. 8 R1. 3 8 pins Dimensions with Front Connecting Socket P2CF-08-@/P2CF-11-@ Dimensions with Back Connecting Socket P3G-08/P3GA-11 17. 4 81. 5 80 81. 5 75 17. 4 H3CR-F H3CR-FN 103. 2* 100. 9 92. 3* H3CR-F8 H3CR-F8N 90. 0 H3CR-F H3CR-FN H3CR-F8 H3CR-F8N Y92F-30 P2CF-11 P2CF-11-E 2. 3* P2CF-08 P2CF-08-E 2. 3* P3GA-11 (When Y92A-48G mounted) Y92F-30 P3G-08 (When Y92A-48G mounted) *These dimensions vary with the kind of DIN track (reference value). Solid-state Twin Timers H3CR-F 29 Solid-state Star-delta Timer H3CR-G DIN 48 × 48-mm Star-delta Timer · A wide star-time range (up to 120 seconds) and star-delta transfer time range (up to 0. 5 seconds). Model Number Structure Model Number Legend H3CR - G 8 @ L @ 12345 1. Outputs None: Star-delta operation contact E: Star-delta operation contact and instantaneous contact 4. Supply Voltage 100-120AC: 100 to 120 VAC 200-240AC: 200 to 240 VAC Ordering Information List of Models Outputs Time-limit contact Time-limit contact and instantaneous contact Supply voltage 100 to 120 VAC 200 to 240 VAC 100 to 120 VAC 200 to 240 VAC Note: Specify both the model number and supply voltage when ordering. Example: H3CR-G8L 100-120AC Supply voltage H3CR-G8L 100-120AC H3CR-G8L 200-240AC H3CR-G8EL 100-120AC H3CR-G8EL 200-240AC 8-pin models 30 Solid-state Star-delta Timer H3CR-G Accessories (Order Separately) Name/specifications Flush Mounting Adapter Y92F-30 Y92F-70 Y92F-71 Mounting Track 50 cm (l) × 7. 3 mm (t) 1 m (l) × 7. 3 mm (t) 1 m (l) × 16 mm (t) End Plate Spacer Protective Cover Track Mounting/ Front Connecting Socket Back Connecting Socket Time Setting Ring Panel Cover (See note 2) 8-pin 8-pin, finger safe type 8-pin 8-pin, finger safe type Setting a specific time Limiting the setting range Light gray (5Y7/1) Black (N1. 5) Medium gray (5Y5/1) Hold-down Clip (See note 3) For PL08 and PL11 Sockets For PF085A Socket PFP-50N PFP-100N PFP-100N2 PFP-M PFP-S Y92A-48B P2CF-08 P2CF-08-E P3G-08 P3G-08 with Y92A-48G (See note 1) Y92S-27 Y92S-28 Y92P-48GL Y92P-48GB Y92P-48GM Y92H-1 Y92H-2 Models Note: 1. Y92A-48G is a finger safe terminal cover which is attached to the P3G-08 Socket. Hold-down Clips are sold in sets of two. Specifications General Item Functions Pin type Operating/Reset method Output type Star-delta timer 8-pin Time-limit operation/Self-reset Time-limit: SPST-NO (star operation circuit) SPST-NO (delta operation circuit) Time-limit: SPST-NO (star operation circuit) SPST-NO (delta operation circuit) Instantaneous: SPST-NO H3CR-G8L H3CR-G8EL Star-delta timer with instantaneous output Mounting method Approved standards DIN track mounting, surface mounting, and flush mounting UL508, CSA C22. 2 No. 14, NK, Lloyds Conforms to EN61812-1 and IEC60664-1 (VDE0110) 4kV/2. Output category according to EN60947-5-1. Time Ranges Time unit Full scale setting 6 12 60 120 Star-delta transfer time 0. 5 to 6 s 1 to 12 s 5 to 60 s 10 to 120 s Programmable at 0. 05 s, 0. 1 s, 0. 25 s or 0. 5 s Star operation time ranges Solid-state Star-delta Timer H3CR-G 31 Ratings Rated supply voltage (See notes 1 and 2. ) 100 to 120 VAC (50/60 Hz), 200 to 240 VAC (50/60 Hz) Operating voltage range Power reset Power consumption Control outputs 85% to 110% of rated supply voltage Minimum power-opening time: 0. 5 s 100 to 120 VAC: approx. 12 VA (3. 0 W) at 240 VAC Contact output: 5 A at 250 VAC/30 VDC, resistive load (cos = 1) Note: 1. Refer to Power Supplies in Safety Precautions for All Timers on page 51 for details. Refer to Power Supplies in Safety Precautions for All Timers on page 51 when using the Timer together with a 2-wire AC proximity sensor. Characteristics Accuracy of operating time Setting error Accuracy of Star-delta transfer time Reset voltage Influence of voltage Influence of temperature Insulation resistance Dielectric strength ±0. 2% FS max. (at 500 VDC) 2, 000 VAC, 50/60 Hz for 1 min (between current-carrying metal parts and exposed non-current-carrying metal parts) 2, 000 VAC, 50/60 Hz for 1 min (between control output terminals and operating circuit) 2, 000 VAC, 50/60 Hz for 1 min (between contacts of different polarities) 1, 000 VAC, 50/60 Hz for 1 min (between contacts not located next to each other) 3 kV (between power terminals) 4. 5 kV (between current-carrying terminal and exposed non-current-carrying metal parts) Impulse withstand voltage Noise immunity Static immunity Vibration resistance Shock resistance Ambient temperature Ambient humidity Life expectancy EMC ±1. 5 kV (between power terminals), square-wave noise by noise simulator (pulse width: 100 ns/1 µs, 1-ns rise) Malfunction: 8 kV Destruction: 15 kV Destruction: 10 to 55 Hz with 0. 75-mm single amplitude for 2 hrs each in three directions Malfunction: 10 to 55 Hz with 0. 5-mm single amplitude for 10 min each in three directions Destruction: 980 m/s2 three times each in six directions Malfunction: 294 m/s2 three times each in six directions Operating: Storage: Operating: -10°C to 55°C (with no icing) -25°C to 65°C (with no icing) 35% to 85% Mechanical: 20 million operations min. (under no load at 1, 800 operations/h) Electrical: 100, 000 operations min. (5 A at 250 VAC, resistive load at 1, 800 operations/h) (See note) (EMI) Emission Enclosure: Emission AC Mains: (EMS) Immunity ESD: EN61812-1 EN55011 Group 1 class A EN55011 Group 1 class A EN61812-1 IEC61000-4-2: 6 kV contact discharge (level 3) 8 kV air discharge (level 3) Immunity RF-interference from AM Radio Waves: IEC61000-4-3: 10 V/m (80 MHz to 1 GHz) (level 3) Immunity RF-interference from Pulse-modulated Radio Waves: IEC61000-4-3: 10 V/m (900±5 MHz) (level 3) Immunity Conducted Disturbance: IEC61000-4-6: 10 V (0. 15 to 80 MHz) (level 3) Immunity Burst: IEC61000-4-4: 2 kV power-line (level 3) 2 kV I/O signal-line (level 4) Immunity Surge: IEC61000-4-5: 1 kV line to line (level 3) 2 kV line to ground (level 3) Case color Degree of protection Weight Light Gray (Munsell 5Y7/1) IP40 (panel surface) H3CR-G8L: approx. 130 g Note: Refer to the Life-test Curve. 32 Solid-state Star-delta Timer H3CR-G Life-test Curve 10, 000 Switching operations (× 103) 5, 000 1, 000 500 30 VDC L/R = 7 ms 250 VAC/30 VDC (cos = 1) Reference: A maximum current of 0. 15 A can be switched at 125 VDC (cos = 1) and a maximum current of 0. 1 A can be switched if L/R is 7 ms. [. . . ] The selectors are of notched so that they will snap when they are properly set. Do not set the selectors midway between notches, otherwise the Timer may break or malfunction. Do not use H3CR-A models (except for H3CR-A@S) in flicker mode, or H3CR-F models at the lowest selector setting. Doing so may result in damage to contacts. Others If the Timer is mounted to a control board, dismount the Timer from the control board or short-circuit the control board circuitry before carrying out a voltage withstand test between the electric circuitry and non-charged metal part of the Timer. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE OMRON H3CR




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual OMRON H3CR will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.