User manual OMRON H2F DATASHEET

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual OMRON H2F. We hope that this OMRON H2F user guide will be useful to you.


OMRON H2F DATASHEET: Download the complete user guide (1132 Ko)

Manual abstract: user guide OMRON H2FDATASHEET

Detailed instructions for use are in the User's Guide.

[. . . ] Mounting method None: Flush mounting F: Surface mounting, DIN track mounting 4. Output type None: SPST-NO C: SPDT 24-hour/Weekly Time Switch H2F 1 Ordering Information Mounting method Control output 24-hour operation Synchronous motor Flush Surface/track SPST-NO SPDT SPST-NO SPDT H2F-D H2F-DC H2F-DF H2F-DFC Quartz motor (with memory protection) H2F-DM H2F-DMC H2F-DMF H2F-DMFC 1-week operation Quartz motor (with memory protection) H2F-WM H2F-WMC H2F-WMF H2F-WMFC Accessories (Order Separately) Extra Programming Tabs 1 pair for each ON/OFF (See note 1. ) Y92S-21 Y92S-42 Rechargeable Battery (See note 2. ) Note: 1. When the life of the Battery has expired, order a replacement using this model number. Specifications Time Ranges Operation period 24-hour 1-week 15 min 1h Minimum division 15 min 2h Minimum set time 166 h Maximum set time 23 h 45 min ON/OFF Cycle Operation period Maximum cycles 96 24-hour 84 1-week Ratings Rated supply voltage Operating voltage range Power consumption Control outputs Terminal screw tightening torque Synchronous motor: 100/110/120 VAC, 200/220/240 VAC (50/60 Hz) (See note. ) Quartz motor: 100 to 240 VAC (50/60 Hz) 85% to 110% of rated supply voltage Synchronous motor: 3 VA max. [. . . ] If the lead wires have been connected to the H2F from the front of the panel before the H2F is mounted in the panel, engage the H2F to part A of the adapter and push it in the direction of B. Then tighten the two screws as described in 2. Panel B H2F Time Switch B A Lead wire 2. After the adapter is mounted, insert the H2F as shown in the figure below. Secure the H2F by tightening the two mounting screws (M3 x 16) included as accessories. A Time Setting To set the time, turn the center knob clockwise to the correct time. Turning it counterclockwise or turning it with your fingers hooked on the setting bracket may cause a malfunction. With 24-hour models, set the hour to the arrow on the upper left corner of the front panel and the minute to the arrow on the center knob. With 1-week models, set the day of the week to the arrow on the upper left corner of the front panel and the hour to the arrow on the center knob. Use the gold setting tabs to set the ON time and the silver ones to set the OFF time. Position the thick leg of the tab toward the outside of the dial and insert the tab securely into the groove on the dial. Three pairs of setting tabs are attached. Store the spare tabs in the compartment at the lower right corner of the front panel. 6 24-hour/Weekly Time Switch H2F Manual Switch SPST-NO Output A 3-position selector switch, located at the lower left corner of the front panel, determines output operation. In the OFF position, the control output is forcibly turned OFF regardless of the setting of the programming tabs. Set to the AUTO position, the output is turned ON and OFF according to the settings of the programing tabs. In the ON position, the output is forcibly turned ON regardless of the setting of the programming tabs. H2F-@M Series (Quartz Motor Models) Battery Remove the battery cover on the rear panel of the H2F, load the provided Battery into the battery box, then turn ON the H2F. If the Battery is not loaded, the H2F will not work properly. Press down. SPDT Output When the manual switch at the lower left corner of the front is set to the OFF position, both load 1 (connected across terminals 4 and 5) and load 2 (across 5 and 6) are turned OFF. Battery cover Slide out When it is set to the AUTO position, the output is turned ON and OFF according to the setting of the programming tabs. When the manual switch is set to the ON position, load 1 (connected across terminals 4 and 5) is turned ON and load 2 (across 5 and 6) is turned OFF. After loading the Battery, be sure to place the cover on the battery box. Battery Output Indicator The output indicator at the upper left corner of the front panel shows the status of the output when the manual switch is set to the AUTO position. Therefore, there is a backup function that is guaranteed for 180 hours on condition that the Battery is loaded into the H2F and charged continuously for 72 hours. If the Battery has no charge, the H2F may not operate immediately after it is turned ON. In that case, continue providing power to the H2F for three or more minutes before setting the time. [. . . ] Before changing times or other settings while power is being supplied, either turn OFF the power on the load side or set the output ON/OFF switch to OFF and confirm the safety of the system. Do not allow metal fragments or lead wire scraps to fall inside the Product. There may occasionally be a risk of explosion resulting in minor injury. ALL DIMENSIONS SHOWN ARE IN MILLIMETERS. To convert millimeters into inches, multiply by 0. 03937. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE OMRON H2F




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual OMRON H2F will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.