[. . . ] Z290-E1-0
Xpectia Series
FZ3
Vision Sensor
USERS MANUAL
Introduction
Thank you for purchasing the FZ3 Series. This manual provides information regarding functions, performance and operating methods that are required for using the FZ3 Series. When using the FZ3 Series, be sure to observe the following: · The FZ3 Series must be operated by personnel knowledgeable in electrical engineering. · To ensure correct use, please read this manual thoroughly to deepen your understanding of the product. [. . . ] Function References Reference: Reference: Reference: Reference: Details (p. 166) Details (p. 166) Details (p. 167) Details (p. 167)
Settings acquisition/change command
Command area top channel +3 0040 0040 0040 0050 0050 1000 2000 3000 1000 2000 +2 Acquires unit data Acquires the current date and time Acquires system version information Sets unit data Sets the date/time Function References Reference: Reference: Reference: Reference: Reference: Details (p. 168) Details (p. 169) Details (p. 169) Details (p. 170) Details (p. 171)
7
Methods for Connecting and Communicating with External Devices
Executing Measurement
Executes measurement one time.
Command (PLC to Controller)
Command area top channel +2 +3 Command code 1010 0010 Bit 15-12 0001 0000 11-8 0000 0000 7-4 0001 0001 3-0 0000 0000 Description Set command codes.
Response (Controller to PLC)
Response area top channel +2 +3 +4 +5 Bit 15-12 0001 0000 0000 0000 11-8 0000 0000 0000 0000 7-4 0001 0001 0000 0000 3-0 0000 0000 0000 0000 Description Command code Store response target command codes. Response code Command execution result OK: 0 (0000 0000) NG: -1 (FFFF FFFF)
Starting Continuous Measurement
Starts continuous measurement.
FZ3 User's Manual
Communicating through Serial Communication (PLC Link)
163
Command (PLC to controller)
Command area top channel +2 +3 Command code 1020 0010 Bit 15-12 0001 0000 11-8 0000 0000 7-4 0010 0001 3-0 0000 0000 Description Set command codes.
Response (Controller to PLC)
Response area top channel +2 +3 +4 +5 Bit 15-12 0001 0000 0000 0000 11-8 0000 0000 0000 0000 7-4 0010 0001 0000 0000 3-0 0000 0000 0000 0000 Description Command code Store response target command codes. Response code Command execution result OK: 0 (0000 0000) NG: -1 (FFFF FFFF)
7
Stopping Continuous Measurement
Stops continuous measurement.
Methods for Connecting and Communicating with External Devices
Command (PLC to controller)
Command area top channel +2 +3 Command code 1030 0010 Bit 15-12 0001 0000 11-8 0000 0000 7-4 0011 0001 3-0 0000 0000 Description Set command codes.
Response (Controller to PLC)
Response area top channel +2 +3 +4 +5 Bit 15-12 0001 0000 0000 0000 11-8 0000 0000 0000 0000 7-4 0011 0001 0000 0000 3-0 0000 0000 0000 0000 Description Command code Store response target command codes. Response code Command execution result OK: 0 (0000 0000) NG: -1 (FFFF FFFF)
Clearing Measurement Values
Clears all measurement values.
164
Communicating through Serial Communication (PLC Link)
FZ3 User's Manual
Command (PLC to controller)
Command area top channel +2 +3 Command code 2010 0010 Bit 15-12 0010 0000 11-8 0000 0000 7-4 0001 0001 3-0 0000 0000 Description Set command codes.
Response (Controller to PLC)
Response area top channel +2 +3 +4 +5 Bit 15-12 0010 0000 0000 0000 11-8 0000 0000 0000 0000 7-4 0001 0001 0000 0000 3-0 0000 0000 0000 0000 Description Command code Store response target command codes. Response code Command execution result OK: 0 (0000 0000) NG: -1 (FFFF FFFF)
7
Saving in Controller
Stores the current system data and scene group in the controller.
Methods for Connecting and Communicating with External Devices
Command (PLC to controller)
Command area top channel +2 +3 Command code 3010 0010 Bit 15-12 0011 0000 11-8 0000 0000 7-4 0001 0001 3-0 0000 0000 Description Set command codes.
Response (Controller to PLC)
Response area top channel +2 +3 +4 +5 Bit 15-12 0011 0000 0000 0000 11-8 0000 0000 0000 0000 7-4 0001 0001 0000 0000 3-0 0000 0000 0000 0000 Description Command code Store response target command codes. Response code Command execution result OK: 0 (0000 0000) NG: -1 (FFFF FFFF)
Restart
Restarts the controller.
Important
When a restart command is executed, BUSY does not turn off even after the command execution bit turns off. After a restart command is executed, perform a memory clear of BUSY on the PLC side.
FZ3 User's Manual
Communicating through Serial Communication (PLC Link)
165
Command (PLC to controller)
Command area top channel +2 +3 Command code F010 0010 Bit 15-12 1111 0010 11-8 0000 0000 7-4 0001 0001 3-0 0000 0000 Description Set command codes.
Response (Controller to PLC)
There is no response because restarting is performed.
Acquiring Scene Number
Acquires the current scene No.
Command (PLC to controller)
7
Methods for Connecting and Communicating with External Devices
Command area top channel +2 +3
Command code 1000 0020
Bit 15-12 0001 0000 11-8 0000 0000 7-4 0000 0010 3-0 0000 0000 Description Set command codes.
Response (Controller to PLC)
Response area top channel +2 +3 +4 +5 +6 +7 Bit 15-12 0001 0000 0000 0000 0000 0000 11-8 0000 0000 0000 0000 0000 0000 7-4 0000 0010 0000 0000 0000 0000 3-0 0000 0000 0000 0000 0000 0000 Description Command code Store response target command codes. Response code Command execution result OK: 0 (0000 0000) NG: -1 (FFFF FFFF) Response data Stores the acquired scene No.
Acquiring Scene Group Number
Acquires the current scene group No.
Command (PLC to controller)
Command area top channel +2 +3 Command code 2000 0020 Bit 15-12 0010 0000 11-8 0000 0000 7-4 0000 0010 3-0 0000 0000 Description Set command codes.
166
Communicating through Serial Communication (PLC Link)
FZ3 User's Manual
Response (Controller to PLC)
Response area top channel +2 +3 +4 +5 +6 +7 Bit 15-12 0010 0000 0000 0000 0000 0000 11-8 0000 0000 0000 0000 0000 0000 7-4 0000 0010 0000 0000 0000 0000 3-0 0000 0000 0000 0000 0000 0000 Description Command code Store response target command codes. Response code Command execution result OK: 0 (0000 0000) NG: -1 (FFFF FFFF) Response data Acquired scene group No.
Scene Switching
Switches the scene number to be used.
Command (PLC to controller)
Command area top channel +2 +3 +4 +5 Bit Command code 1000 0030 15-12 0001 0000 0000 0000 11-8 0000 0000 0000 0000 7-4 0000 0011 0000 0000 3-0 0000 0000 0000 0000 Specifies the scene No. Description
7
Methods for Connecting and Communicating with External Devices
Response (Controller to PLC)
Response area top channel +2 +3 +4 +5 Bit 15-12 0001 0000 0000 0000 11-8 0000 0000 0000 0000 7-4 0000 0011 0000 0000 3-0 0000 0000 0000 0000 Description Command code Store response target command codes. Response code Command execution result OK: 0 (0000 0000) NG: -1 (FFFF FFFF)
Scene Group Switching
Switches the scene group number to be used.
Command (PLC to controller)
Command area top channel +2 +3 Bit Command code 2000 0030 15-12 0010 0000 11-8 0000 0000 7-4 0000 0011 3-0 0000 0000 Set command codes. Description
FZ3 User's Manual
Communicating through Serial Communication (PLC Link)
167
+4 +5
-
0000 0000
0000 0000
0000 0000
0000 0000
Specifies the scene group No.
Response (Controller to PLC)
Response area top channel +2 +3 +4 +5 Bit 15-12 0010 0000 0000 0000 11-8 0000 0000 0000 0000 7-4 0000 0011 0000 0000 3-0 0000 0000 0000 0000 Description Command code Store response target command codes. Response code Command execution result OK: 0 (0000 0000) NG: -1 (FFFF FFFF)
Acquiring Unit Data
7
Methods for Connecting and Communicating with External Devices
Acquires the specified processing unit data.
Important
In processing unit data setting/acquisition, external reference table No. 139 (verification string) of Character Inspection cannot be used.
Command (PLC to controller)
Command area top channel +2 +3 +4 +5 +6 +7 Bit Command code 1000 0040 15-12 0001 0000 0000 0000 0000 0000 11-8 0000 0000 0000 0000 0000 0000 7-4 0000 0100 0000 0000 0000 0000 3-0 0000 0000 0000 0000 0000 0000 Specifies the unit No. Description
Response (Controller to PLC)
Response area top channel +2 +3 +4 +5 +6 +7 Bit 15-12 0001 0000 0000 0000 0000 0000 11-8 0000 0000 0000 0000 0000 0000 7-4 0000 0100 0000 0000 0000 0000 3-0 0000 0000 0000 0000 0000 0000 Description Command code Store response target command codes. Response code Command execution result OK: 0 (0000 0000) NG: -1 (FFFF FFFF) Acquired data (Value multiplied by 1000)
168
Communicating through Serial Communication (PLC Link)
FZ3 User's Manual
Acquiring Date and Time
Acquires the date and time from the internal calendar timer in the controller.
Command (PLC to controller)
Command area top channel +2 +3 Command code 2000 0040 Bit 15-12 0010 0000 11-8 0000 0000 7-4 0000 0100 3-0 0000 0000 Description Set command codes.
Response (Controller to PLC)
Response area top channel +2 +3 +4 +5 +6 +7 +8 +9 +10 +11 +12 +13 +14 +15 +16 +17 Bit 15-12 0010 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 11-8 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 7-4 0000 0100 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 3-0 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 Second data: 0 to 59 Minute data: 0 to 59 Hour data: 0 to 23 Date data: 1 to 31 Month data: 1 to 12 Year data: 1900 to 2100 Description Command code Store response target command codes. Response code Command execution result OK: 0 (0000 0000) NG: -1 (FFFF FFFF)
7
Methods for Connecting and Communicating with External Devices
Acquiring Version Information
Acquires the controller version information.
Command (PLC to Controller)
Command area top channel +2 +3 Command code 3000 0040 Bit 15-12 0011 0000 11-8 0000 0000 7-4 0000 0100 3-0 0000 0000 Description Set command codes.
FZ3 User's Manual
Communicating through Serial Communication (PLC Link)
169
Response (Controller to PLC)
Response area top channel +2 +3 +4 +5 +6 +7 +8 +9 : : Bit 15-12 0011 0000 0000 0000 0000 0000 0000 0000 0000 0000 11-8 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 7-4 0000 0100 0000 0000 0000 0000 0000 0000 0000 0000 3-0 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 Version information character string Description Command code Store response target command codes. Response code Command execution result OK: 0 (0000 0000) NG: -1 (FFFF FFFF)
7
Methods for Connecting and Communicating with External Devices
Setting Unit Data
Sets the specified processing unit data.
Important
In processing unit data setting/acquisition, external reference table No. 139 (verification string) of Character Inspection cannot be used.
Command (PLC to controller)
Command area top channel +2 +3 +4 +5 +6 +7 +8 +9 Bit Command code 1000 0050 0000 0000 0000 0000 0000 0000 15-12 0001 0000 0000 0000 0000 0000 0000 0000 11-8 0000 0000 0000 0000 0000 0000 0000 0000 7-4 0000 0101 0000 0000 0000 0000 0000 0000 3-0 0000 0000 0000 0000 0000 0000 0000 0000 Specifies the unit No. Description
Response (Controller to PLC)
Response area top channel +2 +3 +4 +5 Bit 15-12 0001 0000 0000 0000 11-8 0000 0000 0000 0000 7-4 0000 0101 0000 0000 3-0 0000 0000 0000 0000 Description Command code Store response target command codes. Response code Command execution result OK: 0 (0000 0000) NG: -1 (FFFF FFFF) FZ3 User's Manual
170
Communicating through Serial Communication (PLC Link)
Setting Date and Time
Sets the date and time of the internal calendar timer in the controller.
Command (PLC to controller)
Command area top channel +2 +3 +4 +5 +6 +7 +8 +9 +10 +11 +12 +13 +14 +15 Bit Command code 2000 0050 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 15-12 0010 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 11-8 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 7-4 0000 0101 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 3-0 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 Second data: 0 to 59 Minute data: 0 to 59 Hour data: 0 to 23 Date data: 1 to 31 Month data: 1 to 12 Year data: 1900 to 2100 Set command codes. Description
7
Methods for Connecting and Communicating with External Devices
Response (Controller to PLC)
Response area top channel +2 +3 +4 +5 Bit 15-12 0010 0000 0000 0000 11-8 0000 0000 0000 0000 7-4 0000 0101 0000 0000 3-0 0000 0000 0000 0000 Description Command code Store response target command codes. [. . . ] In the case of FZ3-9 /H9 , the number of processing items is not limited and as many processing items as permitted by the memory can be registered. Note, however, that a warning message is displayed when the available memory drops to below 1 GB. In this case, adjust the inspection flow to ensure at least 1 G of available memory.
9
Appendixes
332 About Limits on the Number of Image Input Processing Items Used FZ3 User's Manual
About Max. Number of Loading Images during Multiple Image Input
The function that enables continuous high speed image input is called the multiple image input function. [. . . ]